18
|
Regency
®
P33-10 Zero Clearance Direct Vent Gas Fireplace
|
18
installation
RIGID PIPE VENTING SYSTEMS
Horizontal or Vertical Terminations
The minimum components required for a basic
horizontal termination are:
1
AstroCap
Horizontal Termination Cap
1 45
o
Elbow
1 Rigid Pipe Adaptor
1 Wall Thimble
1 Length of pipe to suit wall thickness
(see chart)
For siding other than vinyl furring strips may be used,
instead of the vinyl siding standoff, to create a level
surface to mount the vent terminal. The Terminal
must not be recessed into siding.
If a Vinyl Siding Standoff is required (it must be
used with vinyl siding), measure to outside surface
of wall without siding and add 2 inches.
Flat Wall Installation
Max. Wall Vent Length
Thickness (inches) Required (inches)
7 - 1/4"
6"
10 - 1/4"
9"
13 - 1/4"
12"
12-1/4" - 15-7/8" 11" - 14-5/8" Adj. Pipe
18-1/4" - 25-1/4" 11" - 14-5/8" Adj. Pipe
Alternate
Horizontal
Termination
Caps
This product has been evaluated by Intertek
for using a Rigid Pipe Adaptor in conjunction
with Duravent Direct-Vent , Selkirk Direct-Temp,
Ameri Vent Direct venting and Security Secure
Vent systems. Use of these systems with the
Rigid Pipe adaptor is deemed acceptable and
does not affect the Warnok Hersey/Intertek
listing of components.
WARNING:
Do not combine venting components from
different venting systems.
However use of the AstroCap
TM
and FPI Riser
is acceptable with all systems.
When using Rigid Vent other than
Simpson Dura-Vent, 3 screws must be
used to secure rigid pipe to adaptor.
The FPI AstroCap
TM
and FPI Riser Vent terminal are certified for installations using FPI venting systems as well as Simpson Dura-Vent
®
Direct Vent Pro,
American Metal Products Ameri Vent Direct Vent, Security Secure Vent
®
, Selkirk Direct-Temp. AstroCap
TM
is a proprietary trademark of FPI Fireplace
Products International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.