Regency IG34 Gas Inbuilt Fireplace
AERATION SETTINGS
The burner aeration is factory set but may need adjusting due to either the local gas supply, air supply or altitude. This adjustment is performed by
the installer. (Close the aeration for a more yellow fl ame, or open it to make the fl ame bluer).
NG: 13mm
open
LPG: 13mm
open
ULPG:
13mm
open
Note: Any damage due to carboning resulting from improperly setting the aeration and restrictor setting controls is NOT covered
under warranty.
INSTALLATION
IG34-NG: For 0 to 610 meters altitude
IG34-LPG: For 0 to 610 meters altitude
IG34-ULPG: For 0 to 610 meters altitude
Burner Inlet Orifi ce Sizes:
NG
LPG ULPG
Burner
#37
#52 #53
Max. Input
NG
31.7
mj
LPG
30.6
mj
ULPG
26.4
mj
Min. Input
NG
21.1
mj
LPG
25.1
mj
ULPG
20.9
mj
Supply Pressure
NG
1.13
kPa
LPG
2.75
kPa
ULPG
2.75
kPa
Manifold Pressure HIGH LOW
NG
0.87 kPa 0.4kPa
LPG
2.51 kPa 1.6kPa
ULPG
2.51 kPa 1.6kPa
Electrical: 240 V. 50Hz.
Circulation: High/Off/LO speed fan,
150/89 CFM.
Log Set: Ceramic fi ber, 7 per set.
Aeration Setting
NG
13mm open
LPG 13mm open
ULPG 13mm open
System Data
IG34