36
Regency HZO42 (Aus) Gas Fireplace
maintenance
DIGITAL FIREPLACE BURNER CONTROL
REMOVAL
1)
To access to the Digital firebox burner control box - follow steps 1-11 from
the Valve assembly replacement instructions on pages 35,36.
2)
Disconnect the Black Pilot sensor wire with Red Spade connector from
the 'ON' on DFBC (
Digital fireplace burner control) box.
See Diagram 1 below.
3)
Disconnect the Black sparker wire with black spade connector from CN3.
See Diagram 2 below.
4)
Disconnect the white and green On/Off switch wires.
See Diagram 3 below.
5)
Disconnect the yellow ground wire with green diagonal stripe for pilot
(CN2). See Diagram 4 below.
6)
Disconnect the three valve wires (yellow wire with green stripe).
See Diagram 5 below.
Diagram 1
Diagram 5
Diagram 2
Diagram 3
Green
White
Diagram 4
Pilot Sensor
Wire
Sparker Wire
ON/OFF wires
Ground wire
Valve wire