background image

fpi fireplace products international ltd.  6988 Venture st., delta, Bc  canada, V4G 1H4

908-332b

MODELS:    H2100     I3100L

Wood

fireplace insert &

Hearth Heater

10/12/11

owners & installation Manual

Tested by:

Installer

: please complete the details on the back cover 

and leave this manual with the homeowner.

Homeowner:

 please keep these instructions for future reference.

www.regency-fire.com

Содержание H2100

Страница 1: ...332b MODELS H2100 I3100L WOOD Fireplace Insert Hearth Heater 10 12 11 Owners Installation Manual Tested by Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions for future reference www regency fire com ...

Страница 2: ... you have any questions about your product that are not covered in this manual please contact the REGENCY DEALER in your area Keep those REGENCY FIRES burning SAFETY NOTE If this Insert is not properly installed a house fire may result For your safety follow the installation instructions contact local building or fire officials about restrictions and instal lation inspection requirements in your a...

Страница 3: ...a Masonry Fireplace 8 Faceplate and Trim 9 Fan Blower 10 Floor Protection 11 Firebrick Assembly 11 Door Handle 11 Brick Flue Baffle Secondary Air Tube Installation 11 Draft Control 12 Screen Door 12 OPERATING INSTRUCTIONS First Fire 13 Fan Operation All Units 13 Ash Disposal 13 Some Safety Guidelines 13 Creosote 14 Maintenance Maintenance of Gold Plated Doors 14 Door Gasket 14 Door Latch Adjustmen...

Страница 4: ...asonry fi replace or factory built fi replace Contact local building or fi re offi cials about restrictions and installation inspection in your area MADE IN CANADA Manufactured by FPI FIREPLACE PRODUCTS INTERNATIONAL LTD 6988 Venture Street Delta BC V4G 1H4 Duplicate Serial Minimum Clearances to Combustibles Measured from insert body ADJACENT SIDEWALL A 13 330mm MANTLE B 19 480 mm TOP FACING C 18 ...

Страница 5: ...AUTION JAN FEB MAR APR MAY JUN JUL AUG SEPT OCT NOV DEC ADJACENT SIDEWALL A 10 in 255 mm MANTEL B 25 in 635 mm TOP FACING C 14 in 355 mm SIDE FACING D 8 5 in 216mm HEARTH EXTENSION DEPTH E 18 in 455 mm HEARTH EXTENSION ELEVATION F 1 5 in 38 mm HEARTH EXTENSION WIDTH G 6 in 150 mm INSTALL ONLY ON A NON COMBUSTIBLE HEARTH RAISED F 1 5 IN 38 MM ABOVE AN ADJACENT COMBUSTIBLE FLOOR COMBUSTIBLE FLOOR MU...

Страница 6: ...nsert Install and use only in accordance with manufacturer s installation and operating instructions 2 Check your local building codes Building Inspection Department You may require a permit before installing your insert Be aware that local codes and regulations may override some items in the manual WARNING Careless installation is the major cause of safety hazard Check all local building and safe...

Страница 7: ...ctionbetweenyourflueconnectorandthe insertcollar Detailedinstallationinstructionsare included with the kit Position the grill on the inside bodyface side and fastenusingthebolts washersandnutsprovided 2 per side as shown in the diagrams Note Thegrillhasafrontandrear theholes onthefrontsidehaveroundededges and the rear holes have flat edges Adjacent Mantle Top Side Minimum Minimum Minimum Unit Side...

Страница 8: ...uch as difficult start ups smoking out the door and dirty glass Installation Into a Factory Built Fireplace 1 When installed in a factory built fireplace a full stainless steel rigid or flexible flue liner is mandatory for both safety and perform ance purposes When a flue or liner is in use the insert is able to breathe better by allowing a greater draft to be created The greater draft can decreas...

Страница 9: ... at this time Note It may be easier to install the insula tion faceplate top and faceplate trim withtheunitpulledslightlyawayfrom the fireplace face If this is done be very careful not to disturb the con nector when shifting the unit to its final position Now that your insert is installed check once more that all the clearances from the unit to any combustible materials are correct as listed earli...

Страница 10: ...t is in place in order to prevent any damage to the fan To attach follow the instructions provided with the fan 1 Align the fan support with the offset clip on the bottom of the ashlip 2 Slidethesupportsintotheclips Thetension holdingtheclipsinplacemaybeadjustedby increasing or decreasing the offset spacing Caution Label all wires prior to disconnection when servic ing controls Wiring errors can c...

Страница 11: ...100M 2 Tilt the first Baffle Brick down and then slide the2ndBaffleBrickupandback Reposition both baffle bricks flat on the air tubes 3 Important push both baffle bricks so they are tight against the side walls 4 Install the third air tube into the holes on the side channels The notch goes on the right hand side with the air holes facing forward toward the door opening If the tube will not slide i...

Страница 12: ...establishing your first fire it is important that your fully understand the operation of you draft control The draft rod is on the left side of the Inserts and it controls the intensity of the fire by increasing or decreasing the amount of air allowed into the firebox To increase your draft pull open and to decrease push closed Aswellasaprimaryandglasswashairsystem the unit has a full secondary dr...

Страница 13: ...down to keep the fire at a moderate level WARNING Never build a roaring fire in a cold stove Always warm your stove up slowly 5 Once a bed of coals has been established you may adjust the draft control to a low settingtooperatetheunitinitsmostefficient mode 6 During the first couple of hours keep the combustion rate at a moderate level and avoid a large fire until the paint is cured Only then can ...

Страница 14: ...nit Free of Creosote 1 Burn insert with draft control wide open for about15minuteseverymorningduringburn ing season This helps to prevent creosote deposits within the heating system 2 Burn insert with draft control wide open for about 10 15 minutes every time you add freshwood Thisallowsthewoodtoachieve the charcoal stage faster and burns up any wood vapors which might otherwise be deposited withi...

Страница 15: ...Paper Test Test the seal on the loading door with a paper bill Place a paper bill in the gasketed area of the door on a cold stove close the door Try to remove the paper by pulling The paper should not pull out easily if it does try adjusting the door latch if that doesn t solve the problem replace the door gasket Check and lubricate door hinge latch Use only high temperature anti seize lube ie ne...

Страница 16: ...19 948 101 Spring Handle Large Gold 948 135 Spring Handle Large Nickel 20 948 132 Spring Handle Small Gold 948 136 Spring Handle Small Nickel 23 820 235 Flue Brackets Pkg 163 915 I3100L Fan Blower Assembly 24 910 157 P Blower Fan Motor 25 910 678 Power Cord 120 Volts 27 910 142 Fan Thermodisc 28 910 140 Fan Speed Switch HI OFF LOW 3 way 29 910 138 Switch Auto Manual 2 way 30 Grommet Strain Relief ...

Страница 17: ... Set of 3 385 Trim Right Regular 386 Trim Top Regular 387 Trim Left Regular 388 Faceplate Side Regular 389 Faceplate Top Regular 163 912 Faceplate Trim Set Oversize 163 572 Black Trim Oversize Set of 3 395 Trim Right Oversize 396 Trim Top Oversize 397 Trim Left Oversize 398 Faceplate Side Oversize 399 Faceplate Top Oversize Not available as a replacement part ...

Страница 18: ...tor 120 Volts 25 910 678 Power Cord 120 Volts 27 910 142 Fan Thermodisc 28 910 140 Fan Speed Switch HI OFF LOW 3 way 29 910 138 Switch Auto Manual 2 way 30 Grommet Strain Relief 35 120 954 Air Tube Front 36 120 953 Air Tube Rear 37 836 212 Baffle Insulation 38 Insulation Weights 39 120 950 Steel Baffle 948 216 Regency Logo Faceplate H2100M 120 910 Faceplate Trim Set Regular 120 570 Black Trim Regu...

Страница 19: ...2 111 Brick Regular Full Size 1 1 4 x 4 1 2 x 9 71 Brick Partial 1 1 4 x 4 x 9 72 Brick Partial 1 1 4 x 1 3 4 x 9 75 Brick Partial 1 1 4 x 4 x 8 3 4 76 Brick Partial 1 1 4 x 2 x 9 78 Brick Partial 1 1 4 x 2 1 4 x 2 1 4 81 Brick Partial 1 1 4 x 1 1 4 x 9 84 Brick Partial 1 1 4 x 4 1 2 x 8 85 Brick Partial 1 1 4 x 4 1 4 x 8 Not available as a replacement part ...

Страница 20: ...20 Regency Wood Insert Hearth Heater Notes ...

Страница 21: ...Regency Wood Insert Hearth Heater 21 Notes ...

Страница 22: ...22 Regency Wood Insert Hearth Heater Notes ...

Страница 23: ...om unauthorized service persons or dealers At all times FPI reserves the right to inspect product in the field which is claimed to be defective All claims must be submitted to FPI by authorized selling dealers It is essential that all submitted claims provide all of the necessary information including customer name purchase date serial type of unit problem and part or parts requested without this ...

Страница 24: ...__________________________________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial No _ __________________________________________________________ Register your Regency warranty online www regency fire com Reasons to register your product online today View and modify a list of a...

Отзывы: