54
Regency GF900C-2 Gas Fireplace
maintenance
VALVE TRAY REPLACEMENT
6.
Remove burner by removing 14 screws in locations shown below.
7.
Lift out valve tray.
8
.
Replace valve tray and reverse steps.
Diagram 4 - Valve Tray Screw Locations
Diagram 5 - Valve Tray Removal
PRIOR TO SERVICING THE FAN, ENSURE UNIT HAS COOLED TO
ROOM TEMPERATURE, ALL POWER IS DISCONNECTED AND GAS
SUPPLY IT TURNED OFF.
1
. Remove faceplate, inner frame, glass door, and inner panels - see
instructions in this manual.
2
. Remove crystals and stones if installed.
3
. Remove burner tray by removing 3 screws shown in Diagram 1.
4
. Remove burner by removing 2 screws in locations shown below.
Diagram 2 - Burner Screw Locations
Diagram 3 - Air Deflector Screw Locations
Diagram 1 - Burner Tray Screw Locations
5.
Remove air deflector by removing 3 screws in locations shown below.