Regency
®
PG36D Gas Log Fireplace
19
Conversion From NG To LPG Kit #513-968
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION!!
1)
Shut off the gas supply and unplug the
power cord.
2)
Carefully remove the glass, logs and
lava rock.
3)
Remove
burner.
4)
Remove burner orifi ce with a 1/2"
wrench and discard. Use a wrench to
hold on to the elbow behind the orifi ce.
5)
Reinstall new burner orifi ce stamped #52
and tighten.
6)
Pull out the pilot hood by hand.
9)
Adjust the burner aeration setting to and
re-install the burner.
10)
Open the bottom louver.
8)
Put in the new LPG orifi ce with the allen
key. Then put back the pilot hood.
Burner Orifi ce
Pilot
Hood
Pilot
Hood
removed
7)
Remove the pilot orifi ce with the allen
key.
LPG Conversion Kit Contains:
Qty. Part #
Description
1
904-390 Burner
Orifi
ce
#52
1
904-529 5/32"
Allen
Key
1
918-590 Label
"Converted
to
LP"
1
908-528 Red
"LPG"
label
1
910-037 #30
ULPG
Pilot
Orifi
ce
1
918-577 Instruction
Sheet
11)
Remove the front cover by undoing the 2
screws.
Front Cover
12)
Stick the conversion label "This unit has
been converted to LPG" over top of the
serial number decal.
13)
Replace the yellow "NG" label with the
red "LPG" label.
14)
Carefully pull out the control box from
underneath the fi rebox.
Note:
The control box is held in place with
velcro.
Pilot
Orifi ce
INSTALLATION