28
Regency FG39-1 FireGenie Freestanding Gas Stove
MAINTENANCE
GLASS
REPLACEMENT
Your Regency heater is supplied with high tem
-
perature, 5mm Neoceram silica coated ceramic
glass that will withstand the highest heat that
your unit will produce. In the event that you break
your glass, purchase your replacement from
an authorized Regency dealer only, and follow
the step-by-step instructions for replacement.
Removing Glass:
Note: Wearing gloves will protect your
hands while handling glass.
1)
Remove the door from the unit and place
on a soft surface to prevent scratching.
2)
Pull out the door gasket.
3)
Remove the 24 nuts holding the glass
retainers in place.
Do not remove the nuts
underneath the retainers.
4)
Remove the door catch plate.
5)
Remove glass retainers on sides first (3 each
side) then remove two center retainers.
6)
Remove glass from door assembly. When
removing glass, leave white insulation in
place.
7)
Reverse steps 6 - 2.
Safety Screen: Only required in Australia
FAN MAINTENANCE
If your fan requires maintenance or replacement,
access to the fan is through the plate on the rear
wall of the firebox.
NOTE: the unit MUST NOT
be operated without the fan access panel
securely in place and correctly sealed.
If the fan is damaged or needs repair, it
shall be repaired by the manufacturer or its
service agent or similiarily qualified person
to avoid a hazard.
IMPORTANT: These fans collect a lot of
dust from within your home. Ensure
you maintain these fan motors on a
regular basis by vacuuming out the
fan squirrel cages, around the motor,
and around the grills on the back of
the stove.
IMPORTANT
Disconnect power supply
before servicing
WARNING:
Electrical Grounding Instruc-
tions
This appliance is equipped with
a three pronged (grounding) plug
for your protection against shock
hazard and should be plugged
directly into a properly grounded
three-prong receptacle. Do not cut
or remove the grounding prong
from this plug.
Alternate Fan Access:
If the rear access cover is ac-
cessible, it can be removed to
provide access to the fan.
Fan Removal
1)
Unplug or disconnect power source to
stove.
2)
Remove all logs and the rear log support,
then remove the 10 screws holding the ac-
cess panel in place.
3)
Unclip the black and white wires from the
fan motor.
4)
Open both side doors and gently pull the
flex pipe away from the center, otherwise
the fan can catch on the flex pipe during
installation and tear the pipe. Do not tear
or damage the flex pipe.
5)
Lift fan off of the 2 pins, tip back and pull
through firebox opening. Disconnect the
green ground wire from the right side of the
fan as soon as you can reach it.
Fan Replacement
Reverse the above steps (1 - 5). If necessary
install a new gasket before replacing the fan
access panel. Make sure the fan wires and the
ground wire are reattached.
Hint for pushing fan down onto pins - rub a
bit of dish soap on the grommet so it will slide
more easily onto the pin. Check to make sure
the fan is seated properly on the pins - try to
move the fan back and forth, there should be
no noise, if there is check that the grommets
haven't come loose.