8
U32-5 FPI Direct Vent Gas Insert
INSTALLATION
IMPORTANT MESSAGE
SAVE THESE
INSTRUCTIONS
The FPI Gas Insert must be installed in
accordance with these instructions. Carefully
read all the instructions in this manual
fi
rst.
Consult the building authority having jurisdiction
to determine the need for a permit prior to starting
the installation.
NOTE:
Failure to follow the instructions could
cause a malfunction of the heater which could
result in death, serious bodily injury, and/
or property damage. Failure to follow these
instructions may also void your
fi
re insurance
and/or warranty.
FOR YOUR SAFETY
This appliance requires air for proper combustion.
Always provide adequate combustion and
ventilation air. Follow instructions and
information in CAN/CGA B149 (in Canada) or
the National Fuel Gas Code ANSI Z223.1 (in the
USA), regarding requirements for combustion
and ventilation air.
SPECIFICATIONS
At pressures over 1/2 psig, the pipe to the unit
must be disconnected.
Gas Input Capacity:
Natural
Gas
30,000
Btu/h
Propane 30,000
Btu/h
Min. Input
Natural Gas
15,300 Btu/h
Propane 15,300
Btu/h
Fuels:
Approved for use with both natural gas,
and propane. Approved as is for use at 0' to
4,500' (0-1370m).
Electrical:
120V A.C. system.
Circulation Fan:
Variable speed, 110 CFM.
Log Set:
Ceramic
fi
bre, 7 per set.
Vent System:
3" co-linear aluminum
fl
ex.
The ef
fi
ciency rating of the appliance is a
product thermal ef
fi
ciency rating determined
under continuous operating conditions and was
determined independent of any installed system.
GAS PRESSURE
TESTING
The appliance must be isolated from the gas
supply piping system by closing its individual
manual shut off valve during any pressure
testing of the gas supply piping system at test
pressures equal to or less than
1/2 psig. (3.45 kPa).
INSTALLATION INTO A
SOLID FUEL BURNING
FIREPLACE OR
FACTORY BUILT
FIREPLACE
The U32-5 Gas Inserts have been tested and
approved to be vented into any masonry
fi
replace
or approved solid fuel burning factory built
fi
replace that will allow the insert to physically
fi
t into the
fi
rebox. Refer to "Minimum Fireplace
Dimensions" section for minimum
fi
replace
clearances.
If the factory built
fi
replace* height is too low for
your Insert, you may remove the smoke baf
fl
e
plate, damper, refractory (
fi
rebricks), glass
doors, screen rails, screen mesh and log grates
from the factory built
fi
replace as long as these
items are saved and are reinstalled in the event
that the Insert is removed.
Smoke shelves, shields and baf
fl
es may be
removed if attached by mechanical fasteners.
If any part is removed it must not weaken the
structural integrity of the factory built
fi
replace.
NOTE: Any alterations made to the listed solid
fuel burning factory built
fi
replace may void the
listing of the
fi
replace.
*Check with your local inspector before
commencing with this installation.
BEFORE YOU START
Safe installation and operation of this appliance
requires common sense, however, we are
required by the Canadian Safety Standards
and ANSI Standards to make you aware of
the following:
General Safety Information
1)
The appliance installation must conform
with local codes or in the absence of local
codes, with CAN/CGA B149 (in Canada) or
the National Fuel Gas Code ANSI Z223.1 in
the U.S.A. This appliance should be installed
by a quali
fi
ed gas
fi
tter technician only.
2) Installation and repair should be done
by a qualifi ed service person.
3)
The appliance should be inspected before
use and at least annually by a professional
service person. More frequent cleaning
may be required due to excessive lint from
carpeting, bedding material, animal hair, etc.
It is imperative that control compartments,
burners and circulating air passageways of
the appliance be kept clean.
4)
See general construction and assembly
instructions. This appliance may only be
installed in a vented, noncombustible
fi
replace.
5)
This appliance is Listed for bedroom
installations when used with a Listed Millivolt
Thermostat. Some areas may have further
requirements, check local codes before
installation.
6)
Always connect this insert to a vent system
venting to the outside of the building
envelope. Never vent to another room or
inside a building. Make sure that the vent
is properly sized and is of adequate height
to provide the proper draft.
7)
Inspect the venting system annually for
blockage and any signs of deterioration.
8)
Any glass removed for servicing must be
replaced prior to operating the appliance.
9)
To prevent injury, do not allow anyone who
is unfamiliar with the operation to use the
fi
replace.
10)
Due to high temperatures, the appliance
should be located out of high traf
fi
c areas
and away from furniture and draperies.
Children and adults should be alerted to
the hazards of high surface temperatures,
especially the
fi
replace glass and gold
trims, and should stay away to avoid burns
or clothing ignition. Young children should
be carefully supervised when they are in
the same room as the appliance. Clothing
or other
fl
ammable material should not be
placed on or near the appliance.
Emissions from burning wood or gas could
contain chemicals known to the State of
California to cause cancer, birth defects or
other reproductive harm.
Installer must mechanically attach the supplied
label to the inside of the
fi
rebox of the
fi
replace
into which the gas
fi
replace insert is installed.
"
WARNING
: This
fi
replace has been converted
for use with a gas
fi
replace insert only and
cannot be used for burning wood or solid fuels
unless all original parts have been replaced,
and the
fi
replace re-approved by the authority
having jurisdiction."