I1200 Regency Wood Insert

  |     

7

7

installation

CHIMNEY  

SPECIFICATIONS

Before installing, check and clean your chimney 

system thoroughly. If in doubt about its condi-

tion, seek professional advice. Your Regency 

Insert is designed for installation into a masonry 

fireplace that is constructed in accordance with 

the requirements of "The Standard for Chimneys, 

Fireplaces, Vents, and Solid Fuel Burning Ap

-

pliance",  N.F.P.A.  211,  the  National  Building 

Code of Canada, or the applicable local code 

requirements.  

The appliance, when installed, must be electri-

cally grounded in accordance with local codes or, 

in the absence of local codes, with the National 

Electrical Code, ANSI/NFPA 70, or the Canadian 

Electrical code, CSA C22.1.

Regency Inserts are designed to use either a 

5.5" (140mm) or 6" (152mm) flue.

This insert must be connected to a code-ap-

proved masonry chimney or listed factory-built 

fireplace chimney with a direct flue connector 

into the first chimney liner section.  The chimney 

size should not be less than or more than three 

times greater than the cross-sectional area of 

the flue collar.

Requirements for Installing 

Solid-fuel Inserts in Factory-built 

Fireplaces.

1)

  The insert must be tested and meet the 

requirements of UL 1482 (U.S.) and or ULC 

S628 (Canada) when tested in a masonry 

fireplace built per ULC S628.

2)

  The factory-built fireplace must be listed per 

UL 127 or ULC S610.

3)

  Clearances obtained from the masonry fire

-

place tests are also relevant for installation 

in factory-built fireplaces.

4)

  Installation must include a full height listed 

chimney liner type HT requirements (2100 

degree  F.)  per  UL  1777  (U.S.)  or  ULC 

S635 (Canada). The liner must be securely 

attached  to  the  insert  flue  collar  and  the 

chimney top.

5)

  Means must be provided to prevent room 

air passage to the chimney cavity of the 

fireplace.  This  may  be  accomplished  by 

sealing the damper area around the chimney 

liner, or sealing the fireplace front.

Regency Inserts are constructed with the high-

est quality materials and assembled under strict 

quality control procedures that ensure years of 

trouble free and reliable performance.

It is important that you read this manual thor-

oughly and fully understand the installation and 

operating procedures.  Failure to follow instruc-

tions may result in property damage, bodily injury 

or even death. The more you understand the 

way your Regency Insert operates, the more 

enjoyment you will experience from knowing that 

your unit is operating at peak performance.

BEFORE INSTALLING 

YOUR INSERT

1)

  Read all instructions before installing and 

using your fireplace insert.  Install and use 

only in accordance with manufacturer’s 

installation and operating instructions.

2)

 

Check your local building codes - Build-

ing Inspection Department.  You may 

require a permit before installing your 

insert. Be aware that local codes and 

regulations may override some items in 

the manual.

  WARNING:  Careless installation is the 

major cause of safety hazard.  Check all 

local building and safety codes before 

installation of unit.

3)

  Notify your home insurance company that 

you plan to install a fireplace insert.

4) 

Your fireplace insert is heavy and requires 

two or more people to move it safely.  The 

insert and surrounding structure can be 

badly damaged by mishandling.

5)

  If  your  existing  fireplace  damper  control 

will become inaccessible once you have 

installed your Regency Insert, you should 

either remove or secure it in the open posi-

tion.

6)

  Inspect  your  fireplace  and  chimney  prior 

to installing your insert to determine that it 

is free from cracks, loose mortar or other 

signs of damage. If repairs are required, 

they should be completed before installing 

your insert.  Do not remove bricks or mortar 

from your masonry fireplace.

7)

  Do not connect the insert to a chimney 

flue servicing another appliance or an air 

distribution duct.

6)

  Alteration of the fireplace in any manner is not 

permitted with the following exceptions; 

 

 

a. 

  external trim pieces which do not affect 

the operation of the fireplace may be 

removed providing they can be stored 

on or within the fireplace for re-assembly 

if the insert is removed.

 

 

b.

   the chimney damper may be removed 

to install the chimney liner.

7)

  Circulating air chambers (i.e. in a steel 

fireplace liner or metal heat circulator) shall 

not be blocked.

8)

  Means must be provided for removal of the 

insert to clean the chimney flue.

9)

  Inserts that project in front of the fireplace 

must be supplied with appropriate supporting 

means.

10)

 Installer must mechanically attach the sup-

plied label to the inside of the firebox of the 

fireplace into which the insert is installed.

FIREPLACE  

SPECIFICATIONS

Your  fireplace  opening  requires  the  following 

minimum sizes:

Height:  

19" (483mm)   

                   

Width: 

23" (584mm)

Depth:

(w/ standard flue adaptor) 

13-3/4" (349mm)

(w/ offset flue adaptor)

 

16-1/2" (419mm) 

Two faceplates are available to seal the

fireplace opening:

  

Standard 

38" W x 26" H 

 

                     

Oversize 

44" W x 30" H

Emissions from burning  wood or gas could 

contain chemicals known to the State of Cali-

fornia to  cause cancer, birth defects or other 

reproductive harm.

"

WARNING

: This fireplace has been converted 

for use with a wood insert only and cannot be 

used for burning wood or solid fuels unless 

all original parts have been replaced, and the 

fireplace re-approved by the authority having 

jurisdiction."

Содержание Classic I1200S

Страница 1: ...da V4G 1H4 919 538 Classic I1200S Wood Insert 09 14 15 Owners Installation Manual Tested by Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions for future reference www regency fire com ...

Страница 2: ...jority of the chimney is within the building envelope and fully lined It is against federal regulation to operate this wood heater in a manner inconsistent with operating instructions in this manual or if any parts are removed It is against federal regulation to operate this wood heater in a manner inconsistent with operating instructions in this manual CAUTION BURN UNTREATED WOOD ONLY OTHER MATER...

Страница 3: ...lation Into a Factory Built Fireplace 10 Stainless steel smoke deflector Installation 11 Faceplate Trim Optional 12 Bottom Faceplate Fan Support Installation 12 Fan Blower 16 Door Handle 17 Firebrick Assembly 17 Draft Control 17 Brick Flue Baffle Secondary Air Tube Installation 17 Screen Door 18 OPERATING INSTRUCTIONS Seasoned wood 18 First Fire 19 Fan Operation 20 Ash Disposal 20 Some Safety Guid...

Страница 4: ...RATE WITH FEED DOOR CLOSED OPEN TO FEED FIRE ONLY REPLACE GLASS ONLY WITH CERAMIC GLASS 5MM INSPECT AND CLEAN CHIMNEY FREQUENTLY UNDER CERTAIN CONDITIONS OF USE CREOSOTE BUILDUP MAY OCCUR RAPIDLY DO NOT OVERFIRE IF INSERT GLOWS YOU ARE OVER FIRING MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS MEASURED FROM INSERT BODY INSTALL ONLY ON A NON COMBUSTIBLE HEARTH RAISED F 1 5IN 38MM ABOVE AN ADJACENT COM...

Страница 5: ...I1200 Regency Wood Insert 5 5 dimensions WITH STANDARD FLUE ADAPTOR 6 152mm Diameter STANDARD FLUE ADAPTOR 171 932 Regency Inserts are designed to use either a 5 5 140mm or 6 152mm flue ...

Страница 6: ...451mm 22 3 4 578mm 18 3 4 476mm 19 1 2 496mm 22 3 4 578mm 21 3 8 543mm 22 3 4 578mm 21 1 4 540mm 16 7 8 428mm 20 1 8 511mm 6 152mm Diameter OFFSET FLUE ADAPTOR 171 936 12 3 4 from flue centerline to rear of faceplate 16 15 16 430mm Regency Inserts are designed to use either a 5 5 140mm or 6 152mm flue ...

Страница 7: ...and using your fireplace insert Install and use only in accordance with manufacturer s installation and operating instructions 2 Check your local building codes Build ing Inspection Department You may require a permit before installing your insert Be aware that local codes and regulations may override some items in the manual WARNING Careless installation is the major cause of safety hazard Check ...

Страница 8: ...of C 1 25 therefore Rbrick 1 C 1 1 25 0 80 1 8 mineral board of k 0 29 therefore Rmin bd 1 0 29 x 0 125 0 431 Total R Rbrick Rmineral board 0 8 0 431 1 231 Step c Compare proposed system R of 1 231 to specifiedRof0 893 Sinceproposedsystem R is greater than required the system is acceptable DEFINITIONS Thermal Conductance C Btu W hr ft2 o F m2 K Thermal Conductivity k Btu inch W Btu hr ft3 o F m K ...

Страница 9: ...ear of the unit into the fireplace See diagram 3 Ensure that the unit is centered in the existing fireplace and lined up with the flue adaptor 4 Slide the unit back until the flue adaptor is slightly engaged 5 At this point it is recommended to level the unit and ensure that the leveling bolts rest onthesurfaceofthefireplace Thiswillkeep the adaptor from binding as the unit is slid into position 6...

Страница 10: ...tile is used 3 Full flue liner where a stainless steel rigid or flexible liner pipe is routed from the insert outlet collar to the top of the chimney Regency highly recommends the use of a full liner as the safest installation and provides the mostoptimumperformance Yourretailershould be able to help you decide which system would be the best for your application In Canada this fireplace insert mus...

Страница 11: ... off both bolts and slide defector upward and out Install new defector and hand tighten bolts Ensure positive location of the defector prior to hand tightening WARNING Operation of the unit with out proper installation of smoke deflector will void warranty Smoke deflector is installed through the door opening in location shown in diagram Smoke deflector Ensure defector is seated so bolts are situa...

Страница 12: ...installation FACEPLATE TRIM OPTIONAL BOTTOM FACEPLATE FAN SUPPORT INSTALLATION 918 676c 01 28 08 1 I1200 FACEPLATE TRIM FAN OPTIONAL BOTTOM FACEPLATE FAN SUPPORT INSTALLATION Regular Faceplate Dimensions Oversize Faceplate Dimensions ...

Страница 13: ... 2 Diagram 2 Rear View 4 osition the assembled faceplate side and top to the insert nsure to align the draft rod into the opening of the faceplate as well as the side faceplate slots with the bolts in the mounting brackets as shown in Diagram 3 5 easure the height between the hearth and the bottom of the side faceplate 6 utthe bottom faceplate to the measured height using a metal cutting blade 7 R...

Страница 14: ...e Diagram 5 Diagram 6 Shown with Optional Bottom Faceplate Regular Oversize Faceplate Trim Installation Black Trim included with Regular Oversize Faceplate or Optional Brass Trim Fan Installation 12 Install the fan assembly to ash lip of insert as shown in Diagram 7 Diagram 7 13 To install the optional fan support measure the distance between the hearth and the bottom surface of the fan housing as...

Страница 15: ...bly using 4 self tapping screws See Diagram 9 Diagram 9 Rear Bottom View 18 Secure the bottom faceplate to the 3 sided faceplate using the 4 supplied bolts washers 19 Discard both side trims that were included with the regular oversize faceplate and replace with the new extended trims supplied with the fan support bottom faceplate Cut to desired length 20 Fit the trim assembly over the faceplate a...

Страница 16: ... spacing of the clips 3 Ensure that the power cord is not in contact CAUTION Label all wires prior to disconnection when servic ing controls Wiring errors can cause improper and dangerous operation WARNING Electrical Grounding Instructions This appliance is equipped with a three pronged grounding plug for yourprotectionagainstshockhazard and should be plugged directly into a properly grounded thre...

Страница 17: ...ide right As well as a primary and glass wash air system 1 If the two air tubes are installed continue on to Step 2 if not follow the instructions below Installtheairtubeintotheholesinthe side channels The notch goes on the right hand side with the air holes facing toward the door Slide the tube into the left hand side asfaraspossibleandthenbringitback into the hole on the right hand side until it...

Страница 18: ... Softer woods like pine spruce and poplar aspen that is cut split and stacked properly in the early spring maybe be ready for burning in the fall Extremely hard woods like oak and maple and large pieces of firewood may take a minimum of a full year to dry enough Drying may also take longer in damp climates There are a few ways to tell if wood is dry enough to burn efficiently Use as many indicator...

Страница 19: ... out your fire brick and your masonry flue if applicable your draft will increase 10 Forthoseunitsinstalledathigherelevations or into sub standard masonry fireplaces drafting problems may occur Consult an experienced dealer or mason on methods of increasing your draft 11 Some cracking and popping noises may be experienced during the heating up process Thesenoiseswillbeminimalwhenyourunit reaches t...

Страница 20: ...nd switch to either high or Low This will bypass the sensing deviceandallowfullcontrolofthefan Switching from Auto to Manual or High to Low may be done at any time ASH DISPOSAL During constant use ashes should be removed every few days Please take care to prevent the build up of ash around the start up air housing located inside the firebox under the loading door lip DO NOT ALLOW ASHES TO BUILD UP...

Страница 21: ...door gasket material compresses over time Removal of the spacer washer shown in the diagram below will allow the latch to be moved closer to the door frame causing a tighter seal Removeandreplacethenuts washerasshown GLASS CLEANING Do not attempt to clean the glass when it is hot allow the glass to cool before cleaning Do not use abrasive cleaners to clean the glass Your local retailer can supply ...

Страница 22: ...e Caps Nickel 19 948 135 Spring Handle Large Nickel 20 948 136 Spring Handle Small Nickel 170 915 Fan Blower Assembly 24 910 157 P Blower Fan Motor 25 910 678 Power Cord 120 Volts 27 910 142 Fan Thermodisc 28 910 140 Fan Speed Switch HI OFF LOW 3 way 29 910 138 Switch Auto Manual 2 way 30 Grommet Strain Relief 35 074 954 Air Tube 1 Qty 1 36 033 953 Air Tube 3 4 Qty 1 38 073 955 Baffle 2 set 39 820...

Страница 23: ...2 Faceplate Trim Set Oversize Black 171 928 Bottom Piece and Fan Support Regular 171 930 Bottom Piece and Fan Support Oversize 60 Faceplate Right Side Regular Oversize 61 Faceplate Left Side Regular Oversize 62 Faceplate Top Regular Oversize 64 Bottom 1 Piece Faceplate 65 Fan Support Not available as a replacement part ...

Страница 24: ...t Description 170 960 Complete Brick Set 70 Brick Regular Full Size 1 1 4 x 4 1 2 x 9 76 Brick Partial 1 1 4 x 2 x 9 81 Brick Partial 1 1 4 x 1 1 4 x 9 84 Brick Partial 1 1 4 x 4 1 2 x 8 85 Brick Partial 1 1 4 x 4 1 4 x 8 Not available as a replacement part ...

Страница 25: ...I1200 Regency Wood Insert 25 25 notes ...

Страница 26: ...26 I1200 Regency Wood Insert 26 notes ...

Страница 27: ...warranty will be invalid Exclusions This limited Lifetime Warranty does not extend to or include paint door or glass gasketing firebrick back sides bottom or trim It does not cover installation and operational related problems such as over firing use of corrosive driftwood wood preservatives metal foils coal plastic garbage sulphur mill ends oils solvents petroleum products railroad ties paper cardb...

Страница 28: ..._____________________________ Serial No ___________________________________________________________ Register your Regency warranty online www regency fire com Reasons to register your product online today View and modify a list of all your registered products Request automatic email notification of new product updates Stay informed about the current promotions events and special offers on related ...

Отзывы: