Wood Stoves and Inserts Warranty 2015

Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thorough-
ly before it leaves our door. FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime warranty to the original purchaser of a Regency Product. 
This warranty is not transferable.

The Warranty: Limited Lifetime

Covered under the agreement are the following components:

Firebox, ceramic baffle, vermiculite baffle, steel baffles (H2100), convector airmate, castings, cast doors,ashdrawer, glass (thermal breakage), nickel and gold plating (against 
defective manufacture), airtubes (against warpage) and door handles.

The above will be covered for parts and subsidized labour for the first five (5) years and parts only thereafter with the exception of the fireboxes* (see below). 
FPI is not liable for freight or labor on any wood burning firebox/appliance replaced in field*.

Electrical components such as blowers, fan motors, switches, wiring, and thermodisc’s are covered for two (2) years parts and one (1) year subsidized labour* 
from date of purchase.

Repair/replacement parts purchased by the consumer from FPI after the original coverage has expired on the unit will carry a 90 day warranty, valid with a receipt only. Any item 
shown to be defective will be repaired or replaced at our discretion. No labor coverage is included with these parts.

Conditions:

Any part or parts of this unit which in our judgement show evidence of such defects will be repaired or replaced at FPI’s option, through an accredited distributor or agent 
provided that the defective part be returned to the distributor or agent Transportation Prepaid, if requested.

It is the general practice of FPI to charge for larger, higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated for 
manufacturer defect.

The authorized selling dealer is responsible for all in-field service work carried out on your Regency product. FPI will not be liable for results or costs of workmanship from 
unauthorized service persons or dealers.

At all times FPI reserves the right to inspect product in the field which is claimed to be defective.

All claims must be submitted to FPI by authorized selling dealers. It is essential that all submitted claims provide all of the necessary information including customer name, 
purchase date, serial #, type of unit, problem, and part or parts requested. A copy of the bill of sale/proof of purchase must also accompany any submitted claims. without this 
information the warranty will be invalid.

Exclusions:

This limited Lifetime Warranty does not extend to or include paint, door or glass gasketing, firebrick (back,sides,bottom) or trim. It does not cover installation and operational related 
problems such as over-firing, use of corrosive driftwood, wood preservatives, metal foils, coal, plastic, garbage, sulphur, mill ends, oils, solvents, petroleum products, railroad ties, 
paper, cardboard, construction/demolition debris, downdrafts or spillage caused by environmental conditions, nearby trees, buildings, hilltops, mountains, inadequate venting or 
ventilation, excessive offsets, negative air pressures caused by mechanical systems such as furnaces, fans, clothes dryers etc.

At no time will FPI be liable for any consequential damages which exceed the purchase price of the unit. FPI has no obligation to enhance or modify any unit once manufactured. ie. 
as products evolve, field modifications or upgrades will not be performed.

FPI will not be liable for travel costs for service work*.

Installation and environmental problems are not the responsibility of the manufacturer and therefore are not covered under the terms of this warranty policy.

It is the responsibility of the home owner to service and maintain the appliance. If any claims are sent to FPI, you may be asked for service records to ensure the appliance has 
been maintained. Retain all receipts for both service and/or parts which may have been replaced. Lack of service/maintenance is the largest contributor to malfunction of an appli-
ance and is not covered under the terms of this warranty.

Any unit which shows signs of neglect or misuse is not covered under the terms of this warranty policy.
 
The warranty will not extend to any part which has been tampered with or altered in any way, or in our judgment has been subject to misuse. Freight damage to stoves and re-
placement parts is not covered by warranty and is subject to a claim against the freight carrier by the dealer. FPI will not be liable for acts of God, or acts of terrorism, which cause 
malfunction of the appliance.
Performance problems due to operator error will not be covered by this warranty policy.

Malfunction/damage of this appliance due to mother nature (wind, rain, snow, floods, etc.) is not covered under the terms of this warranty policy. Some minor expansion, contraction, 
or movement of certain parts and resulting noise, is normal and not a defect and therefore not covered under this Limited Warranty.
If the appliance has been operated in atmospheres contaminated by chlorine, fluorine, or other damaging chemicals, it will not be covered under this Limited Warranty.

Products made or provided by other manufacturers and used in conjunction with the operation of this appliance without prior authorization from FPI, may nullify your warranty on 
this product.

* Subsidy according to job scale as predetermined by FPI.

Содержание Classic I1200S

Страница 1: ...da V4G 1H4 919 538 Classic I1200S Wood Insert 09 14 15 Owners Installation Manual Tested by Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions for future reference www regency fire com ...

Страница 2: ...jority of the chimney is within the building envelope and fully lined It is against federal regulation to operate this wood heater in a manner inconsistent with operating instructions in this manual or if any parts are removed It is against federal regulation to operate this wood heater in a manner inconsistent with operating instructions in this manual CAUTION BURN UNTREATED WOOD ONLY OTHER MATER...

Страница 3: ...lation Into a Factory Built Fireplace 10 Stainless steel smoke deflector Installation 11 Faceplate Trim Optional 12 Bottom Faceplate Fan Support Installation 12 Fan Blower 16 Door Handle 17 Firebrick Assembly 17 Draft Control 17 Brick Flue Baffle Secondary Air Tube Installation 17 Screen Door 18 OPERATING INSTRUCTIONS Seasoned wood 18 First Fire 19 Fan Operation 20 Ash Disposal 20 Some Safety Guid...

Страница 4: ...RATE WITH FEED DOOR CLOSED OPEN TO FEED FIRE ONLY REPLACE GLASS ONLY WITH CERAMIC GLASS 5MM INSPECT AND CLEAN CHIMNEY FREQUENTLY UNDER CERTAIN CONDITIONS OF USE CREOSOTE BUILDUP MAY OCCUR RAPIDLY DO NOT OVERFIRE IF INSERT GLOWS YOU ARE OVER FIRING MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS MEASURED FROM INSERT BODY INSTALL ONLY ON A NON COMBUSTIBLE HEARTH RAISED F 1 5IN 38MM ABOVE AN ADJACENT COM...

Страница 5: ...I1200 Regency Wood Insert 5 5 dimensions WITH STANDARD FLUE ADAPTOR 6 152mm Diameter STANDARD FLUE ADAPTOR 171 932 Regency Inserts are designed to use either a 5 5 140mm or 6 152mm flue ...

Страница 6: ...451mm 22 3 4 578mm 18 3 4 476mm 19 1 2 496mm 22 3 4 578mm 21 3 8 543mm 22 3 4 578mm 21 1 4 540mm 16 7 8 428mm 20 1 8 511mm 6 152mm Diameter OFFSET FLUE ADAPTOR 171 936 12 3 4 from flue centerline to rear of faceplate 16 15 16 430mm Regency Inserts are designed to use either a 5 5 140mm or 6 152mm flue ...

Страница 7: ...and using your fireplace insert Install and use only in accordance with manufacturer s installation and operating instructions 2 Check your local building codes Build ing Inspection Department You may require a permit before installing your insert Be aware that local codes and regulations may override some items in the manual WARNING Careless installation is the major cause of safety hazard Check ...

Страница 8: ...of C 1 25 therefore Rbrick 1 C 1 1 25 0 80 1 8 mineral board of k 0 29 therefore Rmin bd 1 0 29 x 0 125 0 431 Total R Rbrick Rmineral board 0 8 0 431 1 231 Step c Compare proposed system R of 1 231 to specifiedRof0 893 Sinceproposedsystem R is greater than required the system is acceptable DEFINITIONS Thermal Conductance C Btu W hr ft2 o F m2 K Thermal Conductivity k Btu inch W Btu hr ft3 o F m K ...

Страница 9: ...ear of the unit into the fireplace See diagram 3 Ensure that the unit is centered in the existing fireplace and lined up with the flue adaptor 4 Slide the unit back until the flue adaptor is slightly engaged 5 At this point it is recommended to level the unit and ensure that the leveling bolts rest onthesurfaceofthefireplace Thiswillkeep the adaptor from binding as the unit is slid into position 6...

Страница 10: ...tile is used 3 Full flue liner where a stainless steel rigid or flexible liner pipe is routed from the insert outlet collar to the top of the chimney Regency highly recommends the use of a full liner as the safest installation and provides the mostoptimumperformance Yourretailershould be able to help you decide which system would be the best for your application In Canada this fireplace insert mus...

Страница 11: ... off both bolts and slide defector upward and out Install new defector and hand tighten bolts Ensure positive location of the defector prior to hand tightening WARNING Operation of the unit with out proper installation of smoke deflector will void warranty Smoke deflector is installed through the door opening in location shown in diagram Smoke deflector Ensure defector is seated so bolts are situa...

Страница 12: ...installation FACEPLATE TRIM OPTIONAL BOTTOM FACEPLATE FAN SUPPORT INSTALLATION 918 676c 01 28 08 1 I1200 FACEPLATE TRIM FAN OPTIONAL BOTTOM FACEPLATE FAN SUPPORT INSTALLATION Regular Faceplate Dimensions Oversize Faceplate Dimensions ...

Страница 13: ... 2 Diagram 2 Rear View 4 osition the assembled faceplate side and top to the insert nsure to align the draft rod into the opening of the faceplate as well as the side faceplate slots with the bolts in the mounting brackets as shown in Diagram 3 5 easure the height between the hearth and the bottom of the side faceplate 6 utthe bottom faceplate to the measured height using a metal cutting blade 7 R...

Страница 14: ...e Diagram 5 Diagram 6 Shown with Optional Bottom Faceplate Regular Oversize Faceplate Trim Installation Black Trim included with Regular Oversize Faceplate or Optional Brass Trim Fan Installation 12 Install the fan assembly to ash lip of insert as shown in Diagram 7 Diagram 7 13 To install the optional fan support measure the distance between the hearth and the bottom surface of the fan housing as...

Страница 15: ...bly using 4 self tapping screws See Diagram 9 Diagram 9 Rear Bottom View 18 Secure the bottom faceplate to the 3 sided faceplate using the 4 supplied bolts washers 19 Discard both side trims that were included with the regular oversize faceplate and replace with the new extended trims supplied with the fan support bottom faceplate Cut to desired length 20 Fit the trim assembly over the faceplate a...

Страница 16: ... spacing of the clips 3 Ensure that the power cord is not in contact CAUTION Label all wires prior to disconnection when servic ing controls Wiring errors can cause improper and dangerous operation WARNING Electrical Grounding Instructions This appliance is equipped with a three pronged grounding plug for yourprotectionagainstshockhazard and should be plugged directly into a properly grounded thre...

Страница 17: ...ide right As well as a primary and glass wash air system 1 If the two air tubes are installed continue on to Step 2 if not follow the instructions below Installtheairtubeintotheholesinthe side channels The notch goes on the right hand side with the air holes facing toward the door Slide the tube into the left hand side asfaraspossibleandthenbringitback into the hole on the right hand side until it...

Страница 18: ... Softer woods like pine spruce and poplar aspen that is cut split and stacked properly in the early spring maybe be ready for burning in the fall Extremely hard woods like oak and maple and large pieces of firewood may take a minimum of a full year to dry enough Drying may also take longer in damp climates There are a few ways to tell if wood is dry enough to burn efficiently Use as many indicator...

Страница 19: ... out your fire brick and your masonry flue if applicable your draft will increase 10 Forthoseunitsinstalledathigherelevations or into sub standard masonry fireplaces drafting problems may occur Consult an experienced dealer or mason on methods of increasing your draft 11 Some cracking and popping noises may be experienced during the heating up process Thesenoiseswillbeminimalwhenyourunit reaches t...

Страница 20: ...nd switch to either high or Low This will bypass the sensing deviceandallowfullcontrolofthefan Switching from Auto to Manual or High to Low may be done at any time ASH DISPOSAL During constant use ashes should be removed every few days Please take care to prevent the build up of ash around the start up air housing located inside the firebox under the loading door lip DO NOT ALLOW ASHES TO BUILD UP...

Страница 21: ...door gasket material compresses over time Removal of the spacer washer shown in the diagram below will allow the latch to be moved closer to the door frame causing a tighter seal Removeandreplacethenuts washerasshown GLASS CLEANING Do not attempt to clean the glass when it is hot allow the glass to cool before cleaning Do not use abrasive cleaners to clean the glass Your local retailer can supply ...

Страница 22: ...e Caps Nickel 19 948 135 Spring Handle Large Nickel 20 948 136 Spring Handle Small Nickel 170 915 Fan Blower Assembly 24 910 157 P Blower Fan Motor 25 910 678 Power Cord 120 Volts 27 910 142 Fan Thermodisc 28 910 140 Fan Speed Switch HI OFF LOW 3 way 29 910 138 Switch Auto Manual 2 way 30 Grommet Strain Relief 35 074 954 Air Tube 1 Qty 1 36 033 953 Air Tube 3 4 Qty 1 38 073 955 Baffle 2 set 39 820...

Страница 23: ...2 Faceplate Trim Set Oversize Black 171 928 Bottom Piece and Fan Support Regular 171 930 Bottom Piece and Fan Support Oversize 60 Faceplate Right Side Regular Oversize 61 Faceplate Left Side Regular Oversize 62 Faceplate Top Regular Oversize 64 Bottom 1 Piece Faceplate 65 Fan Support Not available as a replacement part ...

Страница 24: ...t Description 170 960 Complete Brick Set 70 Brick Regular Full Size 1 1 4 x 4 1 2 x 9 76 Brick Partial 1 1 4 x 2 x 9 81 Brick Partial 1 1 4 x 1 1 4 x 9 84 Brick Partial 1 1 4 x 4 1 2 x 8 85 Brick Partial 1 1 4 x 4 1 4 x 8 Not available as a replacement part ...

Страница 25: ...I1200 Regency Wood Insert 25 25 notes ...

Страница 26: ...26 I1200 Regency Wood Insert 26 notes ...

Страница 27: ...warranty will be invalid Exclusions This limited Lifetime Warranty does not extend to or include paint door or glass gasketing firebrick back sides bottom or trim It does not cover installation and operational related problems such as over firing use of corrosive driftwood wood preservatives metal foils coal plastic garbage sulphur mill ends oils solvents petroleum products railroad ties paper cardb...

Страница 28: ..._____________________________ Serial No ___________________________________________________________ Register your Regency warranty online www regency fire com Reasons to register your product online today View and modify a list of all your registered products Request automatic email notification of new product updates Stay informed about the current promotions events and special offers on related ...

Отзывы: