Non-Combustible
Material
Metal
Filler
Strips
Stand-off
Spacers
Metal
Filler
Strip
60" (1524mm)
C
A
B
B
3/4"
(19mm)
2-1/2"
(64mm)
1-1/4"(32mm)
48" (1219mm)
29" (637mm)
2-1/2"
(64mm)
6)
Depending on the height of the hearth in
front of the unit, it may be necessary to trim
the bottom of the mesh sides (B) to fit. Mark
and drill holes for side pieces. Attach with
washers and screws.
7)
Place the top metal filler strip in between
stove and framing to cover the stand-off
space. Fit the strips behind Top mesh "C" so
that it covers the stand-off, and will prevent
mortar from falling through the mesh.
8)
Put the doors on the unit and check that the
veneer on both sides do not interfere with
the door swing.
9)
Use washers and screw top mesh (C) to top
of grill frame. This is attached with the top
edge of the grill frame on piece (B).
10)
Now fasten mesh to wall sheathing and
blend in.
11)
Use only
non-combustible
masonry
products to finish fireplace front.
Finishing Details
Consideration must be given to fireplace
placement when deciding on how to complete
the facing.
IMPORTANT: A tight joint between
masonry and fireplace is necessary to
prevent heat from rolling up the front
to the Face Header.
Top View
Example 1:
Face of Fireplace Flush with Wall Framing.
Example 2:
Face of Fireplace Flush with Non-Combustible.
Top View
Wire Mesh
Mortar
Stone, Tile or Brick
Heavy Expanded Metal
Non-Combustible
Material
Completing The Mantle
A stone mantle may be placed directly above the warm air outlet. If a wood or other combustible
mantle is desired, it must be at least 18 inches above the grill opening and may project up to 10"
(254mm) in front.
24
| FP90 Wood Fireplace
|
24
installation