40
.............................................
|City Series CV60E-1
installation
40 | City Series CV60E-1
Chase Vent Installation Part #686-991 (White)
40
|
City Series CV60E
Chase Vent Installation (White Front)
Framed Opening must be between 3” and 3.5” tall, and at least 60.25” wide to accomodate the Chase vent.
The top of the chase vent opening must be 2” or less from the top of the chase enclosure.
Max 2” (51 mm)
Ceiling
Ceiling
Top of chase enclosure
Max 2” (51 mm)
Stud
Stud
Stud
Stud
60” (1524 mm) Chase Vent
Finishing material
Finishing material
Opening for vent
3”-3.5”
Min 60.25”
60” (1524 mm) Chase Vent
In this application, both the flange and screws to secure the chase vent are exposed as this chase vent is designed to be installed after the finished facing
has been placed on the wall.