background image

City Series Power Vent

CB40EPV Gas Fireplace

MANTEL CLEARANCES CB40EPV 

Due to the extreme heat this fireplace emits, the 
mantel clearances are critical. 

Combustible mantel clearances from top of front facing 
are shown in the diagram on the right.

Note:  Ensure the paint that is used on the mantel 

and the facing is "high quality" or the paint 

may discolour.

MANTEL LEG CLEARANCES

Combustible mantel leg clearances as per diagram:

12"

MANTEL LEG

8-1/2"

CB40E

2

12

6 4

8

10

0

14

9"

15-1/16”

10

20

26

Top of

Fireplace

Opening

12" (305mm)

1/2" Drywall, wood, wood panel, etc.

5-1/8"

To 

Bottomof 

Fireplace 

Opening

Содержание CB40EPV Series

Страница 1: ...ure High 3 8 W C 0 94 kPa 10 5 W C 2 62 kPa Manifold Pressure Low 1 1 W C 0 27 kPa 2 9 W C 0 72 kPa Orifice Size Altitude 0 4500 ft 42 DMS 53 DMS Minimum Input Altitude 0 4500 ft 0 1372m 15 500 BTU h 4 54 kW 15 500 BTU h 4 54 kW Maximum Input Altitude 0 4500 ft 0 1372m 28 500 BTU h 8 33 kW 28 500 BTU h 8 33 kW Vent Sizing 4 Inner 6 5 8 Outer 4 Inner 6 5 8 Outer CSA P 4 1 60 02 60 85 ...

Страница 2: ...ferent clearance and framing requirements check the HeatWave manual for details E F Alcove Clearance 3 sided Dimension Measured From A From Floor Min 0 Bottom of Fireplace Opening A1 Mantel Height min Top of Fireplace Opening B Sidewall on one side 8 1 2 216mm Side of Fireplace Opening C Enclosure Width min 48 7 16 1230mm Minimum inside dimensions D Mantel Depth max E Alcove Width 84 2134mm Side w...

Страница 3: ...ng with vents in front sides or top Full framing with low vents in front or sides Full framing with vents in front or sides K C I A1 A D L J H B L I C D A1 A J G G H H H B I C G A A1 G D J L H H B I B A D C J G G L H H City Series Power Vent CB40EPV Gas Fireplace ...

Страница 4: ...2 1232mm C Framing Depth 19 483mm D Minimum Height to Combustibles 63 1600mm G Vent Centerline Height 56 1 4 1429mm I Gas Connection Opening Height 2 51mm J Gas Connection Height 4 106mm K Gas Connection Inset 13 330mm L Gas Connection Opening Width 3 1 2 89mm Note A combined minimum of 120 square inches of open area is required for the convection air outlet to cool the enclosure Ensure clearances...

Страница 5: ...front facing are shown in the diagram on the right Note Ensure the paint that is used on the mantel and the facing is high quality or the paint may discolour MANTEL LEG CLEARANCES Combustible mantel leg clearances as per diagram 12 MANTEL LEG 8 1 2 CB40E 2 12 6 4 8 10 0 14 9 15 1 16 10 20 26 Top of Fireplace Opening 12 305mm 1 2 Drywall wood wood panel etc 5 1 8 To Bottomof Fireplace Opening ...

Страница 6: ...R TO 4 X 6 5 8 Note Rigid pipe is approved for up to 72 feet Note Flex pipe is approved for up to 40 feet using 2 X 946 756 20 foot flex kits 0 2 4 6 40 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 8 Horizontal Feet 4 0 6 10 12 16 18 14 20 22 24 3 Ft max 32 34 28 26 30 36 38 42 44 40 46 48 50 54 56 52 58 60 Vertical Feet 62 64 66 68 70 72 2 4 6 8 Restrictor Factory Set 1 2 72 overall length Max ...

Страница 7: ... from the back standoffs to the inside mounting surfaceofterminationcap Createalevelsurfacetomounttheventterminal TheTerminalmustnotberecessedintosiding Measurethewallthickness Flat Wall Installation Wall Thickness inches Vent Length Required inches 4 5 1 2 6 7 8 1 2 9 10 11 1 2 12 9 14 1 2 11 14 5 8 Adj Pipe 15 23 1 2 17 24 Adj Pipe Adj Pipe Length Rigid Pipe Adapter o 90 Elbow Pipe Length Vent r...

Страница 8: ...with Vent Terminal 1 510 994 Rigid Pipe adaptor sold separately 1 Power Vent Fan included w Power Vent kit 1 Power Vent Frame included w Power Vent kit 1 911 250 P 45 5 wire BX cable or sold separately 1 911 251 P 90 5 wire BX cable sold separately amount required for install 4 x 6 5 8 Rigid Pipe sold separately 1 946 535 Power Vent Kit sold separately Models Equipped with Surefire Ignition The Po...

Страница 9: ...supply is required to operate this system 946 535 Power Vent Kit with Vent Terminal 2 Max 946 756 20 Flex Kit sold separately 1 Power Vent Fan included w Power Vent kit 1 Power Vent Frame included w Power Vent kit 1 911 250 P 45 5 wire BX cable or sold separately 1 911 251 P 90 5 wire BX cable sold separately 1 946 535 Power Vent Kit sold separately Models Equipped with Surefire Ignition The Power...