62 |
City Series CB40E-12
installation
Vertical Terminations - Rigid Pipe 4" x 6-5/8" (102mm x 168mm)
The minimum components required for a basic vertical termination are:
1 Vertical Termination Cap
1 Rigid Pipe Adaptor (510-994)
1 Ceiling Firestop
1 Flashing
1 Storm Collar
1 Length of pipe to suit wall thickness
(see chart)
When using Rigid Vent other than
Simpson Dura-Vent, 3 screws must be
used to secure rigid pipe to adaptor.
Galvanized pipe is desirable above the roofline due to its higher
corrosion resistance. Continue to add pipe sections through the
flashing until the height of the vent cap meets the minimum height
requirements specified in table below or local codes. Note that
for steep roof pitches, the vertical height must be increased. A
poor draft, or down drafting can result from high wind conditions
near big trees or adjoining roof lines, in these cases, increasing
the vent height may solve the problem.
Roof Pitch
Minimum Vent Height
Feet
Meters
flat to 7/12
2
0.61
over 7/12 to 8/12
2
0.61
over 8/12 to 9/12
2
0.61
over 9/12 to 10/12
2.5
0.76
over 10/12 to 11/12
3.25
0.99
over 11/12 to 12/12 4
1.22
over 12/12 to 14/12 5
1.52
over 14/12 to 16/12 6
1.83
over 16/12 to 18/12
7
2.13
over 18/12 to 20/12
7.5
2.29
over 20/12 to 21/12 8
2.44
Pipe Length
Vertical Terminal
Storm Collar
Flashing
Ceiling Firestop
Rigid Pipe Adapter
This product has been evaluated by Intertek for using a Rigid Pipe Adaptor in conjunction
with Duravent Direct-Vent, Selkirk Direct-Temp, Ameri Vent Direct Venting, ICC Excel
Direct, Olympia Chimney, and Security Secure Vent systems. Use of these systems with
the Rigid Pipe adaptor is deemed acceptable and does not affect the Intertek WHI listing
of components.
WARNING:
Do not combine venting components from different venting systems.
Use of the the AstroCap
TM
and FPI Riser is acceptable with all systems.
The FPI AstroCap
TM
and FPI Riser Vent terminal are certified for installations using FPI venting systems as well as Simpson Dura-Vent
®
Direct Vent, American
Metal Products Ameri Vent Direct Vent, Security Secure Vent
®
, ICC Excel, Selkirk Direct-Temp and Olympia Chimney. AstroCap
TM
is a proprietary trademark
of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.
Содержание CB40E-LP12
Страница 100: ...100 City Series CB40E 12 parts list 16 12 22 21 18 20 19 9 26 25 8 11 26 16 16 6 23 5A 27 17 16 ...
Страница 106: ...106 City Series CB40E 12 warranty ...
Страница 107: ......