background image

Regency Cardinia Freestanding Wood Fire

10

4

13

14

1

5

8

15

10

12

3

7

6

11

1) 

1141704 

Firebrick Retaining Bracket

3) 

1141703 

2mm Back Shield

 

1141702 

Inner Back Shield

4)  

Primary 

Air 

Opening

5) 

8010104 

Stainless Steel Air Bar

6) 8010108 

Firebrick 

Set

7)  

Pedestal

8) 

8010102 

Ash Lip Panel

 8010101  Top 

Panel

10)  8010110 

Door Assembly (without Handle)

11)  8010114 

Door Handle Set

12)  8010106 

Neoceram Glass w/Gasket

13) 8010107 

Air 

Slide

  

8010611 

Steel baffl e (optional)  (A)

         7510206           Cast Plate Set (optional) (B)
14)  8010115 

Glass Retainer Bracket

15)  8010113 

Metal lip inside fi rebox 

16)  936-233 

Door rope seal 5 ft. (not shown)

STOVE ASSEMBLY

         Part # 

  Description 

 

 

PARTS LIST

572

210

346

8

570

10

38

  Optional Cast Plate Set & Steel Baffl e

A

B

Содержание Cardinia F150B-1

Страница 1: ...r property damage Refer to this manual For assistance or additional information consult an authorised installer service agency or the distributor FOR YOUR SAFETY Do not store or use petrol or other flammable vapours and liquids in the vicinity of this or any other appliance Installation and service must be performed by an authorised installer service agency or the gas supplier CARDINIA FREESTANDIN...

Страница 2: ...s manual please contact the REGENCY DEALER in your area Keep those REGENCY FIRES burning SAFETY NOTE If this wood fire is not properly installed a house fire may result For your safety follow the installation instructions contact local building fire officials or authority having jurisdiction about restrictions and installation inspection requirements in your area The authority having jurisdiction ...

Страница 3: ...Door Latch Adjustment 9 Wood Storage 9 PARTS LIST Stove Assembly 10 WARRANTY Warranty 11 Data Badge 4 Unit Dimensions 5 Heat Shield Position 5 INSTALLATION Residential Installation 6 Safety Guidelines and Warnings 6 Brick Installation 6 Clearance to Combustibles 7 Floor Protection 7 OPERATING INSTRUCTIONS Operating Instructions 8 Air Slide Control 8 First Fire 8 ...

Страница 4: ...is the correct one Regency Freestanding Woodfire Model Cardinia F150B 1 TESTED TO AS NZS 4013 1999 TEST REPORT NUMBER HCMG 06 024 11kW 62 WHEN TESTED IN ACCORDANCE WITH AS NZS 4012 JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 2012 2013 2014 Fireplace Products Australia Pty Ltd 21 23 South Link Dandenong VIC 3175 TESTED BY HRL TECHNOLOGY PTY LTD TRAMWAY ROAD MORWELL VICTORIA 3840 2007 MAXIMUM AV...

Страница 5: ...T HEAT SHIELD POSITION The heat shield must be raised if the stove is installed where the rear wall is combustible Remove the heat shield by undoing the 4 bolts Move the heat shield up to align the bottom screw locations screw holes in the firebox and secure in place ...

Страница 6: ...moke spillage as this may set off a false alarm 5 Do not overfire heater If the chimney con nector flue baffle or the stove top begin to glow youareoverfiring Stopaddingfueland close the draft control Overfiring can cause extensive damage to your stove including warpage and premature steel corrosion Overfiring will void your warranty 6 Do not permit creosote or soot build up in the chimney system ...

Страница 7: ...installer in accordance with AS NZS 2918 2001 Flo Met Super Single 1 Hawkwind Standard 2 AHD Special Insulated 3 IMPORTANT 1 The Flo Met Super Single flue kit must be installed with a 130o x 900mm stainless reflective shield between decromesh and active flue plus an additional 900mm x 130o stainless shield positioned 20mm behind decromesh directly on top of the appliance 2 The Hawkwind Standard fl...

Страница 8: ... ports at the top of the firebox just below the flue baffle OPERATING INSTRUCTIONS With your unit now correctly installed and safety inspected by your local authority you are now ready to start a fire Before establishing your first fire it is important that you fully understand the operation of your draft control CAUTION THIS APPLIANCE MUST BE MAINTAINEDANDOPERATEDATALLTIMES IN ACCORDANCE WITH THE...

Страница 9: ... in an extremely hot fire WARNING Thingstorememberincase of a chimney fire 1 Close all draft and damper controls 2 CALL THE FIRE DEPARTMENT Ways to Prevent and Keep Unit Free of Creosote 1 Burn stove with the draft control wide open for about 10 15 minutes every morning during burning season 2 Burn stove with draft control wide open for about 10 15 minutes every time you apply freshwood Thisallows...

Страница 10: ...tal 8 8010102 Ash Lip Panel 8010101 Top Panel 10 8010110 Door Assembly without Handle 11 8010114 Door Handle Set 12 8010106 Neoceram Glass w Gasket 13 8010107 Air Slide 8010611 Steel baffle optional A 7510206 Cast Plate Set optional B 14 8010115 Glass Retainer Bracket 15 8010113 Metal lip inside firebox 16 936 233 Door rope seal 5 ft not shown STOVE ASSEMBLY Part Description PARTS LIST 572 210 346...

Страница 11: ...om unauthorized service persons or dealers At all times FPI reserves the right to inspect product in the field which is claimed to be defective All claims must be submitted to FPI by authorized selling dealers It is essential that all submitted claims provide all of the necessary information in cluding customer name purchase date serial type of unit problem and part or parts requested without this...

Страница 12: ...175 AUSTRALIA NOTE PLEASE RETAIN YOUR INVOICE AS PROOF OF PURCHASE FOR WARRANTY VERIFICATION INCORRECT INSTALLATION IS NOT COVERED BY WARRANTY A SERVICE OR CALLOUT FEE WILL BE CHARGED IN THESE CIRCUMSTANCES Copyright 2012 FPI Fireplace Products International Ltd All rights reserved ...

Отзывы: