background image

Model:  I200B

Owners &

Installation

PLEASE KEEP THESE INSTRUCTIONS FOR 

FUTURE REFERENCE

 

Manual

April-07-2015

918-696d

WARNING:  

Improper installation, adjustment, alteration, service or maintenance can 

cause injury or property damage. Refer to this manual. For assistance 

or additional information consult an authorised installer, service agency 

or the distributor.

BELLERIVE FIREPLACE INSERT

FPI - FIREPLACE PRODUCTS AUSTRALIA PTY LTD.  

1 CONQUEST WAY HALLAM VICTORIA 3803

Содержание Bellerive I200B

Страница 1: ...per installation adjustment alteration service or maintenance can cause injury or property damage Refer to this manual For assistance or additional information consult an authorised installer service agency or the distributor BELLERIVE FIREPLACE INSERT FPI FIREPLACE PRODUCTS AUSTRALIA PTY LTD 1 CONQUEST WAY HALLAM VICTORIA 3803 ...

Страница 2: ...rictions and installation inspection requirements in your area The authority having jurisdiction should be consulted before installation to determine the need to obtain a permit ONLY CLEAN APPLIANCE WITH A DAMP CLOTH NEVER WHEN UNIT IS HOT DO NOT USE ANY ABRASIVE CLEANERS DO NOT BURN WILL VOID WARRANTY Treated wood Tea Tree Oil Based woods Coal Garbage Cardboard Solvents Colored Paper Trash Save t...

Страница 3: ... Storage 12 PARTS LIST Stove Assembly 13 WARRANTY Warranty 15 Data Badge 4 Unit Dimensions 5 INSTALLATION Before Installing Your Insert 6 Residential Installation 6 Safety Guidelines and Warnings 7 Chimney Specifications 7 Wood Insert Specifications 7 Brick Cast Installation 7 Zero Clearance Dimensions 7 Zero Clearance Box Dimensions 7 Fireplace Clearances 8 Installation into a Masonry Fireplace 9...

Страница 4: ... that accompanies each I200B Fireplace Insert We have printed a copy of the contents here for your review SAFETY LABEL NOTE Regency units are constantly being improved Check the label on the unit and if there is a difference the label on the unit is the correct one ...

Страница 5: ...Regency Bellerive Fireplace Insert 5 UNIT DIMENSIONS ...

Страница 6: ...ur insert Be aware that local codes and regulations may override some items in the manual WARNING Careless installation is the major cause of safety hazard Check all local building and safety codes before installation of unit 3 Notify your home insurance company that you plan to install a fireplace insert or hearth heater 4 Your fireplace insert is heavy and requires two or more people to move it ...

Страница 7: ...ety reasons a guard around the fire is recommended 8 The stove consumes air while operating provide adequate ventilation with an air duct or open a window while the stove is in use 9 Do not use grates or andirons or other methods for supporting fuel Burn directly on the base or bricks where supplied 10 Open the draft control fully for 10 to 15 seconds prior to slowly opening the door when refuelli...

Страница 8: ...Regency Bellerive Fireplace Insert 8 INSTALLATION ZERO CLEARANCE BOX DIMENSIONS ZERO CLEARANCE DIMENSIONS ...

Страница 9: ...Regency Bellerive Fireplace Insert 9 FIREPLACE CLEARANCES INSTALLATION ...

Страница 10: ... When a flue or liner is in use the insert is able to breathe better by allowing a greater draft to be created The greater draft can decrease problemssuchas difficultstart ups smoking out the door and dirty glass 2 In order to position the flue liner the exist ing rain cap must be removed from your chimney system In most cases the flue damper should also be removed to allow passage of the liner 3 ...

Страница 11: ...eft side of the fascia in behind the door hinges and align the 4 screw holes with the holes in the firebox Secure in place using 2 screws on top 4 Install the fan fascia by aligning the bottom screw locations with the bottom faceplate See page 13 for fan wiring diagram 5 Re install door Fan Fascia 6 Install the draft plate cover by sliding the tabs into the tab brackets on the inside top of the fi...

Страница 12: ...s at the top of the firebox just below the flue baffle OPERATING INSTRUCTIONS With your unit now correctly installed and safety inspected by your local authority you are now ready to start a fire Before establishing your first fire it is important that you fully understand the operation of your draft control CAUTION THIS APPLIANCE MUST BE MAINTAINEDANDOPERATEDATALLTIMES IN ACCORDANCE WITH THESE IN...

Страница 13: ...n extremely hot fire WARNING Thingstorememberincase of a chimney fire 1 Close all draft and damper controls 2 CALL THE FIRE DEPARTMENT Ways to Prevent and Keep Unit Free of Creosote 1 Burn stove with the draft control wide open for about 10 15 minutes every morning during burning season 2 Burn stove with draft control wide open for about 10 15 minutes every time you apply freshwood Thisallowsthewo...

Страница 14: ...n Liner set 6 8010303 Cast Iron Liner Sides L or R 7 8010305 Cast Iron Liner Back 8 8010306 Stainless Steel Air Bar STOVE ASSEMBLY Part Description PARTS LIST Internal Blower Wiring Diagram 240V Hot Brown Neutral Blue Green Yellow Black Red Attach to Fan Ⅰ Ⅱ 9 8010402 Glass Neoceram w Gasket 10 8010403 Air slide 11 8010406 Door Assembly without handle 12 8010114 Door Handle Set 8010408 Hinge Bar 8...

Страница 15: ... the general practice of Regency Fireplace Products to charge for larger higher priced replacement parts and issue credit once the replaced component has been returned to Regency Fireplace Products and evaluated for manufacturer defect The authorised selling dealer is responsible for all in field service work carried out on your Regency product Regency Fireplace Products will not be liable for res...

Страница 16: ...alled _______________________________________________________ Serial No ___________________________________________________________ Register your Regency warranty online www regency fire com au Reasons to register your product online today View and modify a list of all your registered products Request automatic email notification of new product updates Stay informed about the current promotions ev...

Отзывы: