B41XTCE-11 Gas Fireplace
MANTEL CLEARANCES
Due to the extreme heat this fireplace emits, the mantel clearances are critical.
Note:
Ensure the paint that is used on the mantel
and the facing is "heat resistant" or the paint
may discolour.
MANTEL LEG CLEARANCES
Combustible mantel clearances from top of front
facing are shown in the diagram on the right.
Note: A non-combustible mantel may be
installed at a lower height if the framing is
made of metal studs covered with a non-
combustible board. The non-combustible
mantel when installed at a lower overall
height may not be lower than 6 inches
from the top of the fireplace opening.
Combustible
Mantel Clearances
2
0
12
6
4
8
10
0
Top of
Fireplace
Opening
12”
1"
7”
A
B
C
Non-combustible
Header
(steel stud)
on edge
14
To Floor
12
24
Inches
D
6”
Non-combustible
Standoff
Mantel Clearances
B41XTCE
A
B
C
D
From Top of
Fireplace Opening
32-11/16"
(830mm)
25-13/16"
(656mm)
22-1/16"
(560mm)
17-9/16"
(446mm)
9” Side Wall
(Measured from side of
Fireplace Opening)
7”
4”
Mantel
leg
Mantel
leg
Allowable mantel leg
projection.
3"
1-1/2"
Gas Fireplaces