background image

Owners &

Installation

PLEASE KEEP THESE INSTRUCTIONS FOR 

FUTURE REFERENCE

 

Manual

April-2-2015

918-795c

WARNING:  

Improper installation, adjustment, alteration, service or maintenance can 

cause injury or property damage. Refer to this manual. For assistance or 

additional information consult an authorised installer, service agency or 

the distributor.

FOR YOUR SAFETY

Do not store or use petrol or other flammable vapours and liquids in the 

vicinity of this or any other appliance.

Installation and service must be performed by an authorised installer, 

service agency or the gas supplier.

Model:  F200B-1

Albany F200B-1 Freestanding Wood Fire

FPI - FIREPLACE PRODUCTS AUSTRALIA PTY LTD.  

1 CONQUEST WAY HALLAM VICTORIA 3803

Содержание Albany F200B-1

Страница 1: ... additional information consult an authorised installer service agency or the distributor FOR YOUR SAFETY Do not store or use petrol or other flammable vapours and liquids in the vicinity of this or any other appliance Installation and service must be performed by an authorised installer service agency or the gas supplier Model F200B 1 Albany F200B 1 Freestanding Wood Fire FPI FIREPLACE PRODUCTS A...

Страница 2: ...wood fire is not properly installed a house fire may result For your safety follow the installation instructions contact local building fire officials or authority having jurisdiction about restrictions and installation inspection requirements in your area The authority having jurisdiction should be consulted before installation to determine the need to obtain a permit ONLY CLEAN APPLIANCE WITH A ...

Страница 3: ...rnings 6 Cast Plate Installation 6 Clearance to Combustibles 7 Floor Protection 7 OPERATING INSTRUCTIONS Operating Instructions 8 Air Slide Control 8 First Fire 8 MAINTENANCE Maintenance 9 Creosote 9 Ways to Prevent Keep Units Free of Creosote 9 Glass Maintenance 9 Door Latch Adjustment 9 Wood Storage 9 PARTS LIST Stove Assembly 10 WARRANTY Warranty 11 ...

Страница 4: ... the label that accompanies each F200B 1 Freestanding Wood Fire We have printed a copy of the contents here for your review NOTE Regency units are constantly being improved Check the label on the unit and if there is a difference the label on the unit is the correct one ...

Страница 5: ...Regency Albany Freestanding Wood Fire 5 UNIT DIMENSIONS ...

Страница 6: ...recom mends that your unit is secured to the floor by using the bolt down holes inside the pedestal 11 Do not connect this unit to a chimney serving another appliance SAFETY GUIDELINES AND WARNINGS 1 Never use petrol petrol type lantern fuels kerosene charcoal lighter fuel or similar liquids to start or freshen up a fire in your heater Keep all such liquids well away from the heater while it is in...

Страница 7: ...mm sheets of cement fibre sheet The flue pipe shall extend not less than 4 6m above the top of the floor protector NOTE Installation must be carried out by a licensed installer in accordance with AS NZS 2918 2001 IMPORTANT 1 The Hawkwind Standard flue kit requires one 130o x 900mm stainless reflective shield between the decromesh casing and active flue 2 The AHD Special Insulated flue kit must be ...

Страница 8: ...le OPERATING INSTRUCTIONS With your unit now correctly installed and safety inspected by your local authority you are now ready to start a fire Before establishing your first fire it is important that you fully understand the operation of your draft control CAUTION THIS APPLIANCE MUST BE MAINTAINEDANDOPERATEDATALLTIMES IN ACCORDANCE WITH THESE INSTRUC TIONS CAUTION THE USE OF SOME TYPES OF PRESERV...

Страница 9: ...in an extremely hot fire WARNING Thingstorememberincase of a chimney fire 1 Close all draft and damper controls 2 CALL THE FIRE DEPARTMENT Ways to Prevent and Keep Unit Free of Creosote 1 Burn stove with the draft control wide open for about 10 15 minutes every morning during burning season 2 Burn stove with draft control wide open for about 10 15 minutes every time you apply freshwood Thisallowst...

Страница 10: ... Neoceram with Gasket 7 8010612 Door Assembly without handle 8 8010114 Door Handle Set 9 8010104 Secondary Air Tube 10 8010108 Firebrick optional or where fitted x 16 11 Pedestal Assembly 12 8010609 Ashlip Panel 13 8010610 Fan Assembly Complete 8010611 Steel baffle A 7510206 Cast Plate Set B 14 8010113 Metal lip inside firebox 15 8010115 Glass retaining bracket 16 936 060 Door rope seal 5 ft not s...

Страница 11: ...is the general practice of Regency Fireplace Products to charge for larger higher priced replacement parts and issue credit once the replaced component has been returned to Regency Fireplace Products and evaluated for manufacturer defect The authorised selling dealer is responsible for all in field service work carried out on your Regency product Regency Fireplace Products will not be liable for r...

Страница 12: ..._____________________________________________________ Serial No ___________________________________________________________ Register your Regency warranty online www regency fire com au Reasons to register your product online today View and modify a list of all your registered products Request automatic email notification of new product updates Stay informed about the current promotions events and...