G51 Zero Clearance Kit
INSTALLATION
OPTIONAL OUTSIDE COMBUSTION AIR SUPPLY INSTALLATION
A 4" (100 mm) dia. aluminum flex pipe or equivalent may
be installed from the outside (with a proper exterior cover)
to the Zero Clearance cabinet. There is an outside hole
provided on the rear wall of the kit. This will provide
adequate outside combustion air supply to the heater.
ELECTRICAL SUPPLY
Provide 120 VAC, 60 Hz (in Australia and New Zealand: 240 VAC, 50 Hz) receptacle within 24"(610mm) of the left side
of the appliance (not inside the Zero Clearance Cabinet). Plug the cord on the appliance into the receptacle.
GAS SUPPLY LINE
An authorized service person should install the gas line in accordance with all local building codes. If codes permit,
flex gas line or coiled copper tubing may be used as gas supply line.