36
|
Regency Ultimate™ U900E-11 Gas Fireplace
installation
VERTICAL TERMINATION - CO-LINEAR FLEX SYSTEM INTO A MASONRY CHIMNEY
This appliance is designed to be attached to two 3" (76mm)
co-linear aluminium flex running the full length of the chim-
ney. See the "Venting Arrangements" section for minimum
and maximum heights.
NOTE: Maximum flue height is 30 feet.
Masonry chimneys may take various contours which the
flexible liner will accommodate. However,
keep the flexible
liner as straight as possible
, avoid unnecessary bending.
The Air Intake pipe must be attached to the inlet air collar
of the termination cap.
Required Parts:
Part #
Description
946-529
Co-linear DV Vertical Termination Cap
948-305
3" Flex - 35 ft.
946-563
Co-Axial to Co-Linear Adapter Kit
which contains the following:
Co-linear Flex Adapter
Outer Pipe
Inner Pipe Adapter
510-994
Flue Adaptor
Alternate Approved Caps
46DVA-VC Vertical Termination Cap
or
46DVA-VCH High Wind Cap
+
46DVA-GK 3" Co-linear Adapter with flashing
THE APPLIANCE MUST NOT BE
CONNECTED TO A CHIMNEY FLUE
SERVING A SEPARATE SOLID FUEL
BURNING APPLIANCE.