14
Regency U28-2/U43-3 ULTIMATE Freestanding Gas Stove
INSTALLATION
14 GA.
16 GA.
18 GA.
20 GA.
22 GA.
50 Ft.
32 Ft.
20 Ft.
12 Ft.
9 Ft.
Recommended Maximum Lead Length
(Two-Wire) When Using Wall
Thermostat (CP-2 System)
Wire Size Max. Length
Thermostat Wire Table
FINAL CHECK
Before leaving this unit with the customer, the
installer must ensure that the appliance is firing
correctly. This includes:
1)
Clocking the appliance to ensure the correct
firing rate (rate noted on label) at 15 minutes.
2)
If required, adjusting the primary air to ensure
that the flame does not carbon. First allow
the unit to burn for 15 min. to stabilize.
3)
Check for proper draft.
CAUTION
Any alteration to the product that causes
sooting or carboning that results in damage
to the exterior facia is not the responsibility
of the manufacturer.
OPTIONAL WALL
THERMOSTAT
A wall thermostat may be installed if desired.
Connect the wires as per the wiring diagrams.
Note that the wires are connected to the "TH"
on the gas valve. Use table below to determine
the maximum wire length:
Note: Preferable if the thermostat is installed
on an interior wall.
Regency offers an optional programmable
thermostat but any 250-750 millivolt rated
non-anticipator type thermostat that is CSA,
ULC or UL approved may be used.
CAUTION
Do not connect the millivolt
wall thermostat wires
to the 120V wires.
OPTIONAL REMOTE
CONTROL
Use the Regency Remote Control Kit approved
for this unit. Use of other systems may void
your warranty.
The remote control kit comes with a hand held
transmitter, a receiver and a wall mounting plate.
1)
Choose a convenient location on the wall
to install the receiver and the receptacle
box (protection from extreme heat is very
important). Run wires from the fireplace to
that location, use Thermostat Wire Table.
2)
Connect the wires as per the wiring diagram
above.
CAUTION
Do not connect the millivolt
remote control wires to
the 120V wires.
3)
Install 3 AAA alkaline batteries in transmitter
and 4 AA alkaline batteries in the receiver.
Install the receiver and its cover in the wall.
Switch the remote receiver to "remote"
mode. The remote control is now ready for
operation.
WIRING
This heater does not require a 120V A.C. supply
for operation. In case of a power failure, the
burner switch and the optional remote control/
thermostat will continue to operate. However, a
120V A.C. power supply is needed for the fan/
blower operation.
Caution: Ensure that the wires do
not touch any hot surfaces and are
away from sharp edges.
CAUTION: Label all wires prior
to disconnection when servicing
controls. Wiring errors can cause
improper and dangerous opera-
tion.
WARNING: Electrical Grounding
Instructions
This appliance is equipped with a three
pronged (grounding) plug for your
protection against shock hazard and
should be plugged directly into a prop-
erly grounded three-prong receptacle.
Do not cut or remove the grounding
prong from this plug.