INSTALLATION

Mantel Clearances 

Note:  A non-combustible mantel may be 

installed at a lower height if the fram-
ing is made of metal studs covered 
with a non-combustible board.

CLEARANCES TO 

COMBUSTIBLES

Minimum Clearances to Combustibles

                             From Unit

 

           

Sides

 

A

 

10" / 255mm

Ceiling

 

B

 

47.5" / 1205mm

Mantel

 

C

          13" / 330mm

Max. Mantle Depth

 

12" / 305mm 

 

 

(see Dia. 2)

Min. Alcove Width

 

F

 

48" / 1220 mm

Max. Alcove Depth 

G

 

36" / 915 mm

*No  hearth required.

GAS CONNECTION 

GAS CONNECTION WARNING:

Only persons licensed to work 

with gas piping may make the 

necessary gas connections 

to this appliance.  

1)

  If the appliance is to be installed into an 

existing chimney system, thoroughly clean 
the masonry fi replace.

2)

  The appliance is provided with an opening 

on the right hand side of the control 
compartment. The 9.5mm (3/8") fl exible 
gas hose provided needs to be brought in 
from behind this opening.  Ensure all gas 
connections are tight.

3)

  Locate the center point where the vent 

will pass through the chimney above the 
appliance.  Move the appliance into the 
exact location where it is to be installed.  
Ensure that the Insert is level.

CL

Gas

Inlet

FLUEING

This appliance is designed to be attached to 
two 3" (76mm) co-linear aluminium fl ex running 
the full length of the chimney. The fl ue  length 
must be a minimum length of 8 '  (2.44m) and 
a maximum of 35' (10.7m). See chart below for 
minimum distances from roof. Periodically check 
that the vent is unrestricted.

Masonry chimneys may take various contours 
which the fl exible liner will accommodate. 
However, 

keep the fl exible liner as straight as 

possible

, avoid unnecessary bending.

The Air Intake pipe must  be attached to the inlet 
air collar of the termination cap.

Part # 

Description

948-305 

76mm Flex - 10.6m

46dva-gk Simpson 

Duravent 

Adaptor

46dva-vch  Simpson Vertical high wind cap

MINIMUM FIREPLACE 

DIMENSIONS

The minimum fi replace dimensions for the 
Regency gas space heater are shown in the 
following diagrams:

THE APPLIANCE MUST NOT 

BE CONNECTED TO A

CHIMNEY FLUE SERVING A 

SEPARATE SOLID FUEL

BURNING APPLIANCE AND 

MUST BE TERMINATED TO 

THE OUTDOORS.

Note:    When installing the fl ueing, identify    

         the fl ues.  

            Mark one exhaust and one intake as    

        indicated on the top of the unit.

Содержание IG34-LPG

Страница 1: ...ht any appli ance Do not touch any electri cal switch do not use any phone in your building Immediately call your gas supplierfromaneighbour s phone Follow the gas sup plier s instructions If you cann...

Страница 2: ...you with all the warmth and charm of a fireplace at the flick of a switch The model IG34 of this series has been approved by Australian Gas Association for both safety and efficiency As it also bears...

Страница 3: ...stall 14 Log set installation 15 Glass Door installation 18 Standard Flush Door 18 Optional Flush Trim Faceplate Optional plinth trim Assembly 19 Faceplate and door frame Installation 20 Thermodisc in...

Страница 4: ...the unit and if there is a difference the label on the unit is the correct one DO NO T DO NO T DO NO T DO NO T DO NO T DO NO T OPERATE THIS APPLIANCE BEFORE READING THE INSTRUCTIONS BOOKLET PLACE ARTI...

Страница 5: ...ion 7 Anysafetyglassremovedforservicingmust bereplacedpriortooperatingtheappliance 8 To prevent injury do not allow anyone who is unfamiliar with the operation to use the fireplace 9 Installer must me...

Страница 6: ...ney above the appliance Move the appliance into the exact location where it is to be installed Ensure that the Insert is level C L Gas Inlet FLUEING This appliance is designed to be attached to two 3...

Страница 7: ...r tighten S I T Valve Description 1 On Off Solenoid Valve EV1 2 On Off Solenoid Valve EV2 3 Inlet Pressure Test Point 4 Outlet Pressure Test Point 5 Connection for Pressure Regulator Combustion Chambe...

Страница 8: ...te over the tow ends of the Flex Liner and secure it to the sur rounding masonry using masonry anchor bolts Before installing the baseplate run a bead of non hardening seal and between the Baseplate a...

Страница 9: ...ting controls is NOT covered under warranty INSTALLATION IG34 NG For 0 to 610 meters altitude IG34 LPG For 0 to 610 meters altitude IG34 ULPG For 0 to 610 meters altitude Burner Inlet Orifice Sizes NG...

Страница 10: ...nd discard Use a wrench to hold on to the elbow behind the orifice Control Box Cover Antenna Jumper Location 16 Remove the jumper using a plier 7 Reinstall new burner orifice LPG stamped 51 and tighte...

Страница 11: ...control 23 Check for proper flame appearance and glow on logs C B A 18 Turn on gas supply and plug in power cord 19 Adjusting the Outlet Pressure All the adjustments must be carried out in the followi...

Страница 12: ...discard Use a wrench to hold on to the elbow behind the orifice Control Box Cover Antenna Jumper Location 16 Remove the jumper using a plier 7 Reinstall new burner orifice ULPG stamped 53 and tighten...

Страница 13: ...tic cap A using needle nose pliers Maximum pressure Turn the unit ON to its highest input rating Screw in the nut B to increase the outlet pressure and screw it out to decrease it Use a 10 mm wrench N...

Страница 14: ...ceplate inner door frame and screen if already installed Refer to page 18 in the instruction manual 2 Remove the glass door by undoing 2 latches lift up and out Refer to page 17 in the manual for deta...

Страница 15: ...79 P Vermiculite k 946 669 Platinum Embers supplied with packaged manual Note Install Optional Brick Panels prior to installing logs 1 Carefully remove the logs from the box and unwrap them The logs a...

Страница 16: ...02 45 and across the cutout on Log A 02 43 Cutout Pin Cutout Notch 8 Position notch in Front Right Log F 02 48 on Log E 02 47 and push the bottom right edge against the bracket on the burner tray and...

Страница 17: ...t the bracket and the front edge of the rear burner Side View 11 Separate platinum embers and place on and around the embers and rockwool on the burner tray Avoid stacking platinum embers 12 Test fire...

Страница 18: ...rds the unit diagram 1 Be careful that the glass gasket does not roll up there must be a gap between the gasket and the door lip to ensure that the door sits securely on the unit See Diagram 2 Use the...

Страница 19: ...els flat face down on something soft so they don t scratch 2 Take the top faceplate and align the holes in it with the holes in the side panels Secure with provided nuts and bolts 3 Install faceplate...

Страница 20: ...ing the back of the faceplate with supplied grey adhesive clips 2 Take the limit switch harness from the unit and slide the thermodisc into the bracket located on the top backside of the faceplate Se...

Страница 21: ...tom frame is positioned properly before installing by making sure there is equal spacing on either side 7 Install lower screw below glass door secure with 4 screws 8 Flip bottom louver up to close 9 I...

Страница 22: ...he unit to burn for 15 min to stabilize 3 Check for proper draft CAUTION Any alteration to the product that causes sooting or carboning that results in damage to the exterior facia is not the responsi...

Страница 23: ...E Whentheglassiscoldandtheappliance is lit it may cause condensation and fog the glass This condensation is normal and will disappear in a few minutes as the glass heats up DO NOT ATTEMPT TO CLEAN THE...

Страница 24: ...at as there are temperature changes within the unit these sounds will likely re occur Again this is normal for steel fireboxes Gas Control Valve As the gas control valve turns ON and OFF a dullclickin...

Страница 25: ...lames are steady not lifting or floating If there is a problem call an authorized service person 4 The appliance and flueing system must be inspected before use and at least annu ally by an authorized...

Страница 26: ...and screen 6 Remove the ECS harness from the back clip 7 Pull out the ECS box NOTE The ECS box is held in place with velcro 8 Remove the 2 screws that secure the fan in place 9 Carefully slide the fa...

Страница 27: ...e the glass door logs and black or stainless inner liner if installed 5 Remove the rear log tray burner and grate 6 Disconnect gas line from the valve 7 Remove the firebox base plate by removing the 1...

Страница 28: ...N A N A N A 910 084 Control Box 910 527 Manual Control Switch N A N A N A N A 910 080 Valve 910 521 Control Box Cable 1 910 522 Control Box Cable 2 910 523 Control Box Cable 3 910 525 Control Box Cabl...

Страница 29: ...SIGMA Valve 845 6 336 001 Valve Tray Gasket 7 402 526 Grate Assembly 8 336 535 Burner Assembly NG LPG 9 402 935 Log Set 10 910 936 Pilot Assy NG 3 flame convertible top 910 947 Pilot Assy LPG 3 flame...

Страница 30: ...IG34 Gas Inbuilt Fireplace PARTS LIST FACEPLATE ASSEMBLY Part Description 14 366 942 Plinth Kit 15 336 914 Faceplate Trim Complete Regular 16 336 532 Flush Screen Door Not available as a replacement...

Страница 31: ...r the closest approved service agent is situated more than thirty 30 kilometres from the installation Regency is not obliged to arrange warranty repairs and travel and or additional labour charges wil...

Страница 32: ...__________________________________ Register your Regency warranty online www regency fire com au Reasons to register your product online today View and modify a list of all your registered products Re...

Отзывы: