background image

25

Regency IG34 Gas Inbuilt Fireplace

MAINTENANCE

CAUTION:  ANY SAFETY SCREEN 
OR GUARD REMOVED FOR SERV-
ICING AN APPLIANCE MUST BE 
REPLACED PRIOR TO OPERAT-
ING THE APPLIANCE.

CLOTHING OR OTHER FLAM-
MABLE MATERIAL SHOULD NOT 
BE PLACED ON OR NEAR THE 
APPLIANCE.

DO NOT USE THIS APPLIANCE 
IF ANY PART HAS BEEN UNDER 
WATER. IMMEDIATELY CALL AN 
AUTHORIZED SERVICE TECHNI 
CIAN TO INSPECT THE APPLI-
ANCE AND TO REPLACE ANY 
PART OF CONTROL SYSTEM AND 
ANY GAS CONTROL WHICH HAS 
BEEN UNDER WATER.

WARNING: CHILDREN AND 
ADULTS SHOULD BE ALERTED 
TO THE HAZARDS OF HIGH 
SURFACE TEMPERATURE AND 
SHOULD STAY AWAY TO AVOID 
BURNS OR CLOTHING IGNITION.  
YOUNG CHILDREN SHOULD BE 
CAREFULLY SUPERVISED WHEN 
THEY ARE IN THE SAME ROOM 
AS THE APPLIANCE.

MAINTENANCE 

INSTRUCTIONS

 

Any maintenance required accessing the 
glass door of the unit must be performed 
by an authorized service person.

 

1)

 Always unplug the power cord before 

cleaning. For relighting, refer to lighting 
instructions. Keep the burner and control 
compartment clean by brushing and vacu-
uming at least once a year. When cleaning 
the logs, use a soft clean brush as the logs 
are fragile and easily damaged.

2)

  Clean glass (never when unit is hot), appli-

ance, louvres, and door with a damp cloth.  
Never use an abrasive cleaner. The gold 
louvres (and optional gold door) may be 
scratched if abrasives are used to clean 
them.

 

The heater is fi nished in a heat resistant 
paint and should only be refi nished  with 
heat resistant paint (not with wall paint). 
Regency uses StoveBright Paint - Metallic 
Black #6309.

3)

  Make a  periodic check of burner for proper 

position and condition. Visually check the 
fl ame of the burner periodically, making sure 
the fl ames are steady; not lifting or fl oating. 
If there is a problem, call an authorized 
service person. 

4)

  The appliance and fl ueing system must be 

inspected before use, and at least annu-
ally, by an authorized fi eld service person, 
to ensure that the fl ow of combustion and 
ventilation air is not obstructed. 

 

During the annual service call, the burners 
should be removed from the burner tray 
and cleaned. Replace the embers - do not 
block the burner ports.

5)

  Keep the area near the appliance clear and 

free from combustible materials, gasoline 
and other fl ammable vapours and liquids.

6)

  Verify proper operation after servicing.

LOG REPLACEMENT

The unit should never be used with broken logs. 
Unplug the power cord and allow the unit to cool 
before opening door to carefully remove the logs. 
If for any reason a log should need replacement, 
you must use the proper replacement log. The 
position of these logs must be as shown in the 
diagram under Log Installation.  

Note:   Improper positioning of logs may 

create carbon build-up and will alter 
the unit’s performance which is not 
covered under warranty.

DOOR GLASS 

REPLACEMENT

Your Regency stove is supplied with high tem-
perature, 5 mm Neoceram ceramic glass that 
will withstand the highest heat that your unit will 
produce.  In the event that you break your glass 
by impact, purchase your replacement from an 
authorised Regency dealer only, and follow our 
step-by-step instructions for replacement.

WARNING: do not operate appli-
ance with the glass front removed, 
cracked or broken. Replacement 
of the glass should be done by 
a licensed or authorised service 
person.

Flush Glass Replacement

Slide old glass out of the side frames and 
replace with new glass. 

GLASS GASKET

 
If the glass gasket requires replacement use 
glass gasket (Part # 936-155).

WARNING

HOT GLASS

DO NOT TOUCH

NEVER

WILL

CAUSE BURNS

GLASS

UNTIL COOLED

ALLOW CHILDREN

TO TOUCH GLASS

Содержание IG34-LPG

Страница 1: ...ht any appli ance Do not touch any electri cal switch do not use any phone in your building Immediately call your gas supplierfromaneighbour s phone Follow the gas sup plier s instructions If you cann...

Страница 2: ...you with all the warmth and charm of a fireplace at the flick of a switch The model IG34 of this series has been approved by Australian Gas Association for both safety and efficiency As it also bears...

Страница 3: ...stall 14 Log set installation 15 Glass Door installation 18 Standard Flush Door 18 Optional Flush Trim Faceplate Optional plinth trim Assembly 19 Faceplate and door frame Installation 20 Thermodisc in...

Страница 4: ...the unit and if there is a difference the label on the unit is the correct one DO NO T DO NO T DO NO T DO NO T DO NO T DO NO T OPERATE THIS APPLIANCE BEFORE READING THE INSTRUCTIONS BOOKLET PLACE ARTI...

Страница 5: ...ion 7 Anysafetyglassremovedforservicingmust bereplacedpriortooperatingtheappliance 8 To prevent injury do not allow anyone who is unfamiliar with the operation to use the fireplace 9 Installer must me...

Страница 6: ...ney above the appliance Move the appliance into the exact location where it is to be installed Ensure that the Insert is level C L Gas Inlet FLUEING This appliance is designed to be attached to two 3...

Страница 7: ...r tighten S I T Valve Description 1 On Off Solenoid Valve EV1 2 On Off Solenoid Valve EV2 3 Inlet Pressure Test Point 4 Outlet Pressure Test Point 5 Connection for Pressure Regulator Combustion Chambe...

Страница 8: ...te over the tow ends of the Flex Liner and secure it to the sur rounding masonry using masonry anchor bolts Before installing the baseplate run a bead of non hardening seal and between the Baseplate a...

Страница 9: ...ting controls is NOT covered under warranty INSTALLATION IG34 NG For 0 to 610 meters altitude IG34 LPG For 0 to 610 meters altitude IG34 ULPG For 0 to 610 meters altitude Burner Inlet Orifice Sizes NG...

Страница 10: ...nd discard Use a wrench to hold on to the elbow behind the orifice Control Box Cover Antenna Jumper Location 16 Remove the jumper using a plier 7 Reinstall new burner orifice LPG stamped 51 and tighte...

Страница 11: ...control 23 Check for proper flame appearance and glow on logs C B A 18 Turn on gas supply and plug in power cord 19 Adjusting the Outlet Pressure All the adjustments must be carried out in the followi...

Страница 12: ...discard Use a wrench to hold on to the elbow behind the orifice Control Box Cover Antenna Jumper Location 16 Remove the jumper using a plier 7 Reinstall new burner orifice ULPG stamped 53 and tighten...

Страница 13: ...tic cap A using needle nose pliers Maximum pressure Turn the unit ON to its highest input rating Screw in the nut B to increase the outlet pressure and screw it out to decrease it Use a 10 mm wrench N...

Страница 14: ...ceplate inner door frame and screen if already installed Refer to page 18 in the instruction manual 2 Remove the glass door by undoing 2 latches lift up and out Refer to page 17 in the manual for deta...

Страница 15: ...79 P Vermiculite k 946 669 Platinum Embers supplied with packaged manual Note Install Optional Brick Panels prior to installing logs 1 Carefully remove the logs from the box and unwrap them The logs a...

Страница 16: ...02 45 and across the cutout on Log A 02 43 Cutout Pin Cutout Notch 8 Position notch in Front Right Log F 02 48 on Log E 02 47 and push the bottom right edge against the bracket on the burner tray and...

Страница 17: ...t the bracket and the front edge of the rear burner Side View 11 Separate platinum embers and place on and around the embers and rockwool on the burner tray Avoid stacking platinum embers 12 Test fire...

Страница 18: ...rds the unit diagram 1 Be careful that the glass gasket does not roll up there must be a gap between the gasket and the door lip to ensure that the door sits securely on the unit See Diagram 2 Use the...

Страница 19: ...els flat face down on something soft so they don t scratch 2 Take the top faceplate and align the holes in it with the holes in the side panels Secure with provided nuts and bolts 3 Install faceplate...

Страница 20: ...ing the back of the faceplate with supplied grey adhesive clips 2 Take the limit switch harness from the unit and slide the thermodisc into the bracket located on the top backside of the faceplate Se...

Страница 21: ...tom frame is positioned properly before installing by making sure there is equal spacing on either side 7 Install lower screw below glass door secure with 4 screws 8 Flip bottom louver up to close 9 I...

Страница 22: ...he unit to burn for 15 min to stabilize 3 Check for proper draft CAUTION Any alteration to the product that causes sooting or carboning that results in damage to the exterior facia is not the responsi...

Страница 23: ...E Whentheglassiscoldandtheappliance is lit it may cause condensation and fog the glass This condensation is normal and will disappear in a few minutes as the glass heats up DO NOT ATTEMPT TO CLEAN THE...

Страница 24: ...at as there are temperature changes within the unit these sounds will likely re occur Again this is normal for steel fireboxes Gas Control Valve As the gas control valve turns ON and OFF a dullclickin...

Страница 25: ...lames are steady not lifting or floating If there is a problem call an authorized service person 4 The appliance and flueing system must be inspected before use and at least annu ally by an authorized...

Страница 26: ...and screen 6 Remove the ECS harness from the back clip 7 Pull out the ECS box NOTE The ECS box is held in place with velcro 8 Remove the 2 screws that secure the fan in place 9 Carefully slide the fa...

Страница 27: ...e the glass door logs and black or stainless inner liner if installed 5 Remove the rear log tray burner and grate 6 Disconnect gas line from the valve 7 Remove the firebox base plate by removing the 1...

Страница 28: ...N A N A N A 910 084 Control Box 910 527 Manual Control Switch N A N A N A N A 910 080 Valve 910 521 Control Box Cable 1 910 522 Control Box Cable 2 910 523 Control Box Cable 3 910 525 Control Box Cabl...

Страница 29: ...SIGMA Valve 845 6 336 001 Valve Tray Gasket 7 402 526 Grate Assembly 8 336 535 Burner Assembly NG LPG 9 402 935 Log Set 10 910 936 Pilot Assy NG 3 flame convertible top 910 947 Pilot Assy LPG 3 flame...

Страница 30: ...IG34 Gas Inbuilt Fireplace PARTS LIST FACEPLATE ASSEMBLY Part Description 14 366 942 Plinth Kit 15 336 914 Faceplate Trim Complete Regular 16 336 532 Flush Screen Door Not available as a replacement...

Страница 31: ...r the closest approved service agent is situated more than thirty 30 kilometres from the installation Regency is not obliged to arrange warranty repairs and travel and or additional labour charges wil...

Страница 32: ...__________________________________ Register your Regency warranty online www regency fire com au Reasons to register your product online today View and modify a list of all your registered products Re...

Отзывы: