8

Regency I31-2 Gas Fireplace Inbuilt

LOG SET

INSTALLATION

Read the instructions below carefully and
refer to the diagrams.  If logs are broken
do not use the unit until they are replaced.
Broken logs can  interfere with the pilot
operation.

The gas log kit contains the following:

a)

02-43 Rear Log

902-227

b)

02-45 Front Right Log

902-229

c)

02-56 Middle Left Log

902-230

d)

02-46 Left Top Log

902-231

e )

02-47 Center Log

902-232

f)

02-48 Middle Right Log

902-226

g)

02-44 Front Left Log

902-228

h)

Embers and Rockwool

i)

Vermiculite and Ember combination

Note: Install Optional Brick Panels prior

to installing logs.

Vermiculite and

embers.

Vermiculite and

embers.

Vermiculite and

embers.

The "02" refer numbers (i.e. 02-43) are

molded into the rear of each log.

INSTALLATION

The smoke should be drawn into the spill tube.
If the smoke is still not drawn into the spill tube,
turn the unit off and check for the cause of the
lack of draft. If  necessary, rectify.

Diagram 1

Diagram 2

Diagram 3

For wind turbulent sites, a wind cap may rem-
edy the problem.

Note: The thermally activated safety
switch will sense the change in temper-
ature and shut down the gas valve in the
event of a severe downdraft or a blocked
or disconnected flue. The switch acts as
a safety shut-off to prevent a build-up of
carbon monoxide.  If the flue is blocked or
has no "draw", the switch will automati-
cally shut off the supply of gas within 5 -
10 minutes. Tampering with the switch
can result in carbon monoxide (CO) poi-
soning and possible death.

If the heater turns off because of lack of
draft during the spillage test, check for
the cause and if necessary, rectify.

The thermally actuated safety switch will
automatically reset after it has cooled off.
The switch will continue to cycle until the
draft problem is corrected. DO NOT BY-
PASS OR DISCONNECT THIS SWITCH.

OPTIONAL

BRICK PANEL

1) Unwrap the brick pattern panels from the

protective wrapping.

2) Remove the glass front if it is already

installed (see manual).

3) Put the rear brick panel flat against the back

of the unit.

4) Before installing the side brick panels, loos-

en the screws for the brick tabs enough so
that you can slide the brick tabs on to the
screws easily but that the tabs are secure.
For the location of the side brick tab screws
see diagram 1.

5) Remove the brick tabs and slide the side

brick panels into position.  See diagram 3.
Install the brick tabs.  See diagram 2.

1) Carefully remove the logs from the box and

unwrap them.  The logs are fragile, handle
with care - do not force into position.

2) Sprinkle the vermiculite and ember combi-

nation around the firebox base.

3) Place Rear Log A)02-43 on the two pins on

the rear log support.

Содержание I31-2

Страница 1: ...ry to light any appli ance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplierfromaneighbour s phone Follow the gas sup plier sinstructions If y...

Страница 2: ...s been designed to provide you with all the warmth and charm of a fireplace at the flick of a switch The model I31 2 of this series has been approved by Australian Gas Association for both safety and...

Страница 3: ...Fan Maintenance 15 TroubleShooting 17 Parts List 18 Warranty Warranty 23 Page UnitDimensions 2 SafetyLabel 4 Installation For Your Safety 5 Specifications 5 Installation Checklist 5 MaterialsRequired...

Страница 4: ...label that accompanies each Regency I31 2 Gas Inbuilt fireplace We have printed a copy of the contents here for your review DATA BADGE NOTE Regency units are con stantly being improved Check the labe...

Страница 5: ...ustible fire place The appliance and flue should be enclosed when installed or passing through a living area where children may come in contact with it 5 Always connect this space heater to a chimney...

Страница 6: ...TIONS INSTALLATION NOTE Mantel clearances for Installation into a Zero Clearance Kit are differ ent Please refer to the Zero Clear ance Kit Manual for details Mantel Clearances with Bay and Flush Louv...

Страница 7: ...ED TOACHIMNEYFLUESERVINGASEPARATE SOLIDFUELBURNINGAPPLIANCE Thisapplianceisdesignedtoattachtoa100mm diameter twin skin or listed gas fuel type flue liner running the full length of the chimney A minim...

Страница 8: ...cts as a safety shut off to prevent a build up of carbon monoxide If the flue is blocked or has no draw the switch will automati cally shut off the supply of gas within 5 10 minutes Tampering with the...

Страница 9: ...ne end of burner to the other If there is any flame hesitation check that area for any blockage of the burner port 12 Install flush glass and optional bay glass as per instructions in this manual D 02...

Страница 10: ...ace the trim on the assembled faceplate panels aligning the wire connections from the switches with the notch on the left side panel 5 Hookup the 3 Fan Switch wires to the fan switch on the left side...

Страница 11: ...ion fit if the louvre needs to be adjusted bend the bracket out as shown in the diagram 3 Place the bottom of the flush glass behind the bottom glass trim 4 Secure the glass with the two glass clips a...

Страница 12: ...14 GA 16 GA 18 GA 20 GA 22 GA 15 24 m 9 75 m 6 10 m 3 66 m 2 71 m WIRING CAUTION Label all wires prior to disconnectionwhen servicingcontrols Wiring errors can cause improper and dangerous operation W...

Страница 13: ...the unit cooled to below a useful heat output range the fan will shut off automatically NORMAL OPERATING SOUNDS OF GAS APPLIANCES It is possible that you will hear some sounds from your gas appliance...

Страница 14: ...label 1 Push in gas control knob slightly and turn clockwise to OFF Knob cannot be turned from PILOT to OFF unless knob is pushed in slightly Do not force 2 Wait five 5 minutes to clear out any gas If...

Страница 15: ...arranty Clean any fingerprints off before turn ing the unit on If the top louvres start to discolour check the door gasket seal and replace if necessary LOG REPLACEMENT The unit should never be used w...

Страница 16: ...of dish soap on the grommet so it will slide more easily onto the pin Check to make sure the fan is seated properly on the pins this is very important try to move the fan back and forth there should...

Страница 17: ...oting continues open aeration shutter on burner Note To clean glass remove and wipe with cloth or paper towel Check gas pressure Clean out carbon spider webs lint etc from burner area Check and replac...

Страница 18: ...1 Spill Switch Bracket 12 910 220 Spill Switch 13 Levelling Bolts 5 16 x 3 Hex Head 948 216 Logo Plate 918 044 Manual Masport 400 945 Brick Panel Set 33 902 255 Brick Panel Back 34 902 176 Brick Panel...

Страница 19: ...Gasket Valve Heat Shield 56 Pilot Bracket 57 904 240 Burner Orifice Nat Gas 37 904 390 Burner Orifice Propane 52 58 910 424 Pilot ON OFF Extension Knob 59 910 426 Flame HI LOW Extension Knob 60 402 0...

Страница 20: ...plate Trim Left Assy Regular 401 913 Faceplate Trim Compelte Oversize 141 Faceplate Side Right Oversize 142 Faceplate Top Oversize 143 Faceplate Side Left Oversize 401 524 Trims Packaged Oversize 144...

Страница 21: ...0 314 P Center Glass 110 902 183 Bay Brick Panel 400 935 Bay Door Trim Set Gold 400 989 Bay Door Trim Set Steel 111 Bay Door Trim Top 112 904 196 1 Round Ceramic Magnet 113 Bay Door Trim Bottom Flush...

Страница 22: ..._______________________________________________ ______________________________________________________ _______________________________________________________________ _________________________________...

Страница 23: ...y Assur anceTeamcarefullyinspectseachunitthoroughlybeforeit leaves our door Regency Industries Ltd is pleased to extendthislimitedlifetimewarrantytotheoriginalpurchaser of a Regency Product The Warran...

Страница 24: ...Printed in Canada...