20
L390E / HZI390E Direct Vent Gas Insert
installation
ac POWER adaPtOR InstallatIOn (fOR suREfIRE systEms)
an optional ac power adaptor may be installed as a constant power source for the surefire system.
IMPORTANT: Recommend removing the 4-AA batteries in the SureFire receiver.
This will avoid battery leakage and power drainage. 4-AA Battery pack may be re-installed into receiver during power outages.
NOTE: For all
Gas Fireplaces
120 volt power must be brought to the
receptacle box
inside the
bottom of the firebox
(provided with the unit).
All Freestanding
Gas Stoves
& Gas
Inserts
will need a
receptacle box
located
outside / near the unit
so that the AC Power Adaptor can be plugged in.
Install ac adaPtOR WIth suREfIRE Wall REcEIvER sWItch Only - (WIthOut REmOtE)
Install ac adaPtOR WIth suREfIRE PROflamE Gt / Gtm REmOtE
1)
Locate “DC Supply” tag on wire harness. For location in unit
see remote installation page in owners manual.
919-063
08/15/2011
2)
Connect the male end from AC adaptor to the female end
tagged “DC Supply” on wiring harness in unit.
2)
Locate FCM - COM connector on the Remote wire harness -
see manual for location in unit.
3)
Plug in wire adaptor to FCM - COM connector - be careful not
to damage ends. This only fits one way.
3)
Plug AC adaptor into 120V wall outlet (or into 120V receptacle if
installed inside the gas fireplace firebox).
4)
Neatly tuck any loose AC Power Adaptor wires neatly underneath /
inside the appliance.
Note:
Ensure that wires do not touch the underside of the firebox
(keep wires away from the heat as much as possible).
FCM - COM
AC adaptor
wire adaptor
1)
Connect the male end of the AC adaptor to the female end of the
wire adaptor (supplied with AC adaptor) together as shown
.
AC adaptor
Wire adaptor
FCM - COM
4)
Plug AC adaptor into 120V wall outlet (or into 120V receptacle if
installed inside the gas fireplace firebox).
5)
Neatly tuck any loose AC Power Adaptor wires neatly underneath /
inside the appliance.
Note:
Ensure that wires do not touch the underside of the firebox
(keep wires away from the heat as much as possible).
1