Regency Horizon® HZO42 Gas Fireplace
|
9
9
|
installation
Caution Requirements
The top, back and sides of the fireplace are defined by
standoffs. The metal ends of the standoff may
NOT
be
recessed into combustible construction.
WARNING
Fire hazard is an extreme risk
if these clearances (air space) to combustible materials are not
adhered to. It is of greatest importance that this fireplace be
installed only in accordance with these instructions.
MINIMUM CLEARANCES TO COMBUSTIBLES
The clearances listed below are Minimum distances unless otherwise stated:
A major cause of fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this
fireplace be installed only in accordance with these instructions.
F
E
D
A
C
B
HZO42 Clearance Requirements
Clearance:
Dimension
Measured From:
A: Sidewall
11" (203mm)
Side of Fireplace Opening
B: Ceiling
36" (914mm)
Top of Fireplace Opening
C: Mantel Height (min.)
18" (457mm)
Top of Fireplace Opening
D: Mantel Depth (max.)
12" (304mm)
From Wall
E: Alcove Width
57"(1148mm)
Wall to Wall (Minimum)
F: Alcove Depth
36" (914mm)
Front to Back Wall (Maximum)
Notes:
0"
No Hearth Required
E
F
Alcove
A
B
WARNING:
When installing this appliance; do not cover or surround
with insulation.
This appliance can overheat and cause malfunction
and component failure, if covered, or partially covered.
If the appliance is installed inside a chase, insulation
must be installed on the walls of the chase, not on the
appliance.
Содержание Horizon HZO42-LP
Страница 48: ......
Страница 49: ...Regency Horizon HZO42 Gas Fireplace 49 49 notes ...
Страница 50: ...50 Regency Horizon HZO42 Gas Fireplace 50 notes ...
Страница 51: ......