installation
Grandview
®
G800C-1 Gas Fireplace | 81
01.20.22
920-191a
G800C
1
FAN WALL CONTROL INSTALLATION KIT
1. Connect the supplied speed control switch and unit receptacle to
the 120V mains power supply by following the wiring diagram as
shown.
The fan may be instaled with the optional Wall Control Kit (761-
974), which allows the fan speed control module located inside the
unit to be replaced by a wall mounted fan speed control.
WALL CONTROL KIT MUST BE INSTALLED DURING UNIT
INSTALLATION STAGE.
1
2
3
4
5
6
7
4
8
9
10
11
12
13
120 V
60 Hz
2. Remove the fan speed control module from the fan kit by breaking
the connection of the wires at the connectors shown below. Dis-
card the fan speed control module.
Item Part No.
Description
1
911-159
Power Cord
2
910-692
Green Ground Wire
3
911-290/P Fan
4
911-240
Brown Connector Cable
5
910-896
Black Wire
6
910-142
Fan Thermodisc
7
910-811
Black Wire
Item Part No.
Description
1
910-367
Junction Box
2
910-412
Speed Contron Switch w/Lead Wires
3
910-417
White Knob
4
N/A
Wire Nuts
5
910-366
White Faceplate
6
N/A
14 AWG Wire*
7
910-687
Wire Clamp
8
910-429
Receptacle Box Inside Stove
9
910-428
Receptacle (dedicated use by stove fan)
10
N/A
Copper Ground Wire*
11
N/A
White Wire (Neutral)*
12
N/A
Black Wire (Hot)*
13
N/A
14 AWG Wire*
Neutral/Neutre
Live/
Sous
tension
1
2
4
3
6
7
5
*Not supplied by Regency.
Fan Wall Control Installation Kit (Part # 761-974)