installation
54 | Grandview
®
G800C-1 Gas Fireplace
Vertical Venting with Two 90
o
Elbows
Vertical Venting with Three 90
o
Elbows
V1
V
H
V
H1
H
V1
One 90
o
elbow = Two 45
o
elbows.
Option
V
H
V + V1
With these options,
maximum total pipe length
is 30 feet with minimum
of 7 feet total vertical
and maximum 8 feet total
horizontal.
Please note minimum 1
foot between 90
o
elbows
is required.
A)
0' Min. 2' Max.
1' Min.
B)
1' Min. 4' Max.
3' Min.
C)
2' Min. 5' Max.
4' Min.
D)
3' Min. 6' Max.
5' Min.
E)
4' Min. 7' Max.
6' Min.
F)
5' Min. 8' Max.
7' Min.
Lengths do not include elbow indicated.
*Required when using rigid venting
One 90
o
elbow = Two 45
o
elbows.
Option
V
H + H1
V + V1
With these options,
maximum total pipe length
is 30 feet with minimum
of 10 feet total vertical
and maximum 8 feet total
horizontal.
Please note minimum 1
foot between 90
o
elbows
is required.
A)
0' Min. 2' Max.
2' Min.
B)
1' Min. 2' Max.
3' Min.
C)
2' Min. 3' Max.
4' Min.
D)
3' Min. 4' Max.
6' Min.
E)
4' Min. 5' Max.
7' Min.
F)
5' Min. 6' Max.
8' Min.
G)
6' Min. 7' Max.
9' Min.
H)
7' Min. 8' Max.
10' Min.
Lengths do not include elbow indicated.