Regency GF950L Gas Fireplace
51
maintenance
FAN SERVICE
PRIOR TO SERVICING THE FAN, ENSURE UNIT HAS COOLED TO
ROOM TEMPERATURE, ALL POWER IS DISCONNECTED AND GAS
SUPPLY IS TURNED OFF.
1
. Remove faceplate, inner frame, glass door, front trim piece and inner
panels - see instructions in this manual.
2
. Remove logs.
3
. Remove burner side panels by lifting out as shown in Diagram 1.
4
. Remove burner by removing 2 screws in locations shown below.
7.
Loosen three (3) screws to remove heat deflector shown in Diagram
5.
8.
Remove two (2) screws to remove fan shown in Diagram 6.
9.
Reverse steps to reinstall fan.
6.
Remove access panel by removing eight(8) screws in locations
shown in Diagram 4.
Diagram 3 - Log Tray screws
Diagram 5 - Heat Deflector Screws
Diagram 6 - Fan Screws
Diagram 1 - Burner Side Panels
Diagram 2 - Burner Screw Locations
Diagram 4 - Access Tray screws
5
. Remove rear log tray by removing 3 screws as shown in Diagram 3
below.