Regency Fireplace Products F2403M Скачать руководство пользователя страница 4

4

Regency Freestanding Woodstove

SAFETY LABEL

This is a copy of the label that accompanies each 

Regency Freestanding Woodstove (F2403M). 

We have printed a copy of the contents here 

for your review.

NOTE:

 Regency units are constantly being 

improved. Check the label on the unit and if 

there is a difference, the label on the unit is the 

correct one.

MODEL:  REGENCY  MEDIUM  FREESTANDING STOVE -  F2400M

TESTED TO:  UL-1482-2011 / ULC-S627-00 / UL-737-2011  REPORT NO:219-S-02-2

THE F2400M MEETS UL737 STANDARD FOR FIREPLACE STOVES WHEN A FIRESCREEN IS PROVIDED.

MINIMUM ALCOVE CEILING HEIGHT: 2.15 M / 7 FT         MAXIMUM ALCOVE DEPTH 915 MM / 36 IN.    

MINIMUM CLEARANCES FOR HORIZONTAL CONNECTOR TO CEILING: 455 MM / 18"

THE SPACE BENEATH THE HEATER MUST NOT BE OBSTRUCTED. OPERATE ONLY WITH FIREBRICKS IN PLACE.

F2400M WITHOUT 

AIRMATE SHIELD

F2400M WITH 

AIRMATE SHIELD

K  405 mm  /  16 in

L  150 mm  /  6 in

M  150 mm  /  6 in

FOR USE WITH SOLID WOOD FUEL ONLY.  USE OF OTHER FUELS MAY DAMAGE HEATER AND CREATE A HAZARDOUS CONDITION.  DO NOT OBSTRUCT COMBUSTION 

AIR OPENINGS.  OPERATE ONLY WITH FIREBRICKS IN PLACE.  RISK OF SMOKE AND FLAME SPILLAGE, OPERATE ONLY WITH DOORS FULLY OPEN OR FULLY CLOSED. 

IF INSTALLED IN A MOBILE HOME OPERATE ONLY WITH DOORS FULLY CLOSED - OPEN FEED DOOR TO FEED FIRE ONLY. WHEN OPERATED WITH DOORS OPEN THE 

MANUFACTURER SUPPLIED SCREEN MUST BE USED. DO NOT USE GRATE OR ELEVATE FIRE.  BUILD WOOD FIRE DIRECTLY ON HEARTH.  DO NOT OVERFIRE - IF HEATER 

OR CHIMNEY CONNECTOR GLOWS YOU ARE OVERFIRING.  INSPECT AND CLEAN CHIMNEY AND CONNECTOR FREQUENTLY.  UNDER CERTAIN CONDITIONS OF USE 

CREOSOTE BUILDUP MAY OCCUR RAPIDLY.  KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL AWAY FROM HEATER.  REPLACE GLASS ONLY WITH NEOCERAM 

GLASS. COMBUSTIBLE FLOOR MUST BE PROTECTED BY NON-COMBUSTIBLE MATERIAL EXTENDING BENEATH THE HEATER AND TO THE FRONT AND SIDES AS INDICATED 

OR TO THE NEAREST PERMITTED COMBUSTIBLE MATERIAL.

OPTIONAL COMPONENT: FAN (846-515), ELECTRICAL RATING: VOLTS 115, 60 HZ, 2 AMPS, SCREEN DOOR (846-101)

DANGER: RISK OF ELECTRIC SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT. DO NOT ROUTE POWER CORD UNDER OR IN FRONT OF APPLIANCE.

COMPONENTS REQUIRED FOR MOBILE HOME INSTALLATION: OUTSIDE AIR KIT AND ONE OF THE FOLLOWING DOUBLE WALL CONNECTOR

IN CANADA: 

LISTED SECURITY MODEL DP, OR OLIVER MACLEOD PRO-VENT PV DOUBLE WALLED CONNECTOR WITH  LISTED CHIMNEY SYSTEM: SECURITY MODEL 

S2100, ICC EXCEL 2100, SELKIRK SENTINAL CF.

IN  USA:    LISTED  DOUBLE  WALL  CONNECTORS  SECURITY  MODEL  DP,  SELKIRK  MODEL  DS,  OLIVER  MACLEOD  PRO  VENT  PV,  SIMPSON  DURA 

VENT  MODEL  DVL,  GSW  SUPER  PIPE  6,  METAL-FAB  DOUBLE  WALL.    CONNECTED  TO  ONE  OF  THE  FOLLOWING  COMPATIBLE  CHIMNEY  SYSTEMS 

SECURITY  MODEL  S2100  OR  MODEL  ASHT,  SELKIRK  MODEL  SSII,  OLIVER  MACLEOD  PRO  JET  3103,  SIMPSON  DURA  PLUS,  GSW  MODEL  SC  OR 

METAL-FAB  TEMP/GUARD,  AMERI-TEC  HS,   ICC  EXCEL  2100  .   USE  CHIMNEY  COMPONENTS  AS  SPECIFIED  IN  INSTALLATION  INSTRUCTIONS.

AUTEUR MINIMALE DU PLAFOND DE L’ALCÔVE : 2.15 M / 7 PL   PROFONDEUR MAXIMALE DE L’ALCÔVE : 915 MM / 36 PO

DÉGAGEMENT MINIMAL DU PLAFOND POUR UN CONNECTEUR HORIZONTAL : 455 MM / 18 PO.

L’ESPACE AU-DESSOUS DU POÊLE NE DOIT PAS ÊTRE OBSTRUÉ. UTILISER SEULEMENT AVEC LES BRIQUES RÉFRACTAIRES EN PLACE.

POUR UTILISATION AVEC BOIS SOLIDE SEULEMENT. L’UTILISATION D’AUTRES COMBUSTIBLES PEUT ENDOMMAGER LE POÊLE ET CRÉER UNE CONDITION DANGEREUSE. 

NE PAS OBSTRUER LES OUVERTURES D’AIR DE COMBUSTION. UTILISER SEULEMENT AVEC LA PORTE FERMÉE – OUVRIR LA PORTE DE CHARGEMENT POUR ALIMENTER 

LE FEU SEULEMENT. NE PAS UTILISER DE GRILLE À BÛCHES NI SURÉLEVER LE FEU. MONTER LE FEU DE BOIS DIRECTEMENT SUR L’ÂTRE. NE PAS SURCHAUFFER – SI 

LE POÊLE OU LE CONNECTEUR DE CHEMINÉE SE MET À ROUGIR, VOUS SURCHAUFFEZ. INSPECTEZ ET NETTOYEZ FRÉQUEMMENT LA CHEMINÉE ET LE CONNECTEUREN 

CERTAINES CONDITIONS D’UTILISATION, UN DÉPÔT DE CRÉOSOTE PEUT SE FORMER RAPIDEMENT. GARDEZ LES MEUBLES ET AUTRES MATÉRIAUX COMBUSTIBLES 

ÉLOIGNÉS DU POÊLE. REMPLACEZ LA VITRE SEULEMENT PAR DU VERRE EN NEOCERAM. LE PLANCHER COMBUSTIBLE DOIT ÊTRE PROTÉGÉ PAR DES MATÉRIAUX NON 

COMBUSTIBLES DÉPASSANT DU DESSOUS, DU DEVANT ET DES CÔTÉS DU POÊLE, TEL QU’INDIQUÉ, OU JUSQU’AU MATÉRIAU COMBUSTIBLE LE PLUS PRÈS PERMIS.

COMPOSANTS EN OPTION : VENTILATEUR (846-515), ALIMENTATION ÉLECTRIQUE : 115 VOLTS, 60 HZ, 2 AMP.

DANGER  :  RISQUE  D’ÉLECTROCUTION.  DÉCONNECTER  L’ALIMENTATION  ÉLECTRIQUE AVANT  DE  FAIRE  L’ENTRETIEN  DU  POÊLE.  NE  PAS  INSTALLER  LE  CORDON 

ÉLECTRIQUE SOUS OU DEVANT L’APPAREIL.

COMPOSANTS EXIGÉS POUR INSTALLATION DANS UNE MAISON MOBILE : KIT DE PRISE D’AIR EXTÉRIEUR ET L’UN DES CONNECTEURS DE CHEMINÉE À DOUBLE PAROI 

SUIVANTS :

AU CANADA : CONNECTEURS DE CHEMINÉE HOMOLOGUÉS À DOUBLE PAROI : SECURITY MODÈLE DP, OU OLIVER MACLEOD PRO-VENT PV, AVEC SYSTÈME DE CHEMINÉE 

HOMOLOGUÉ : SECURITY MODÈLE S2100, ICC EXCEL 2100, SUPER VENT 2100, SUPERPRO 2100, CF SENTINAL.

AUX ÉTATS-UNIS : CONNECTEURS DE CHEMINÉE HOMOLOGUÉS À DOUBLE PAROI : SECURITY MODÈLE DP, SELKIRK MODEL DS, OLIVER MACLEOD PRO VENT PV, 

SIMPSON DURA VENT MODÈLE DVL, GSW SUPER PIPE 6, METAL-FAB À DOUBLE PAROI. CONNECTÉ À L’UN DES SYSTÈMES DE CHEMINÉE COMPATIBLES SUIVANTS : 

SECURITY MODÈLE S2100 OU MODÈLE ASHT, SELKIRK MODÈLE SSII, OLIVER MACLEOD PRO JET 3103, SIMPSON DURA PLUS, GSW MODÈLE SC OU METAL-FAB TEMP/

GUARD, AMERI-TECHS, ICC EXCEL 2100, SIMPSON DURA PLUS HTC. UTILISER LES COMPOSANTS DE CHEMINÉE SPÉCIFIÉS DANS LES INSTRUCTIONS D’INSTALLATION.

244

 CAUTION

HOT WHILE IN OPERATION DO NOT TOUCH.  KEEP CHILDREN,

CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE

SKIN BURNS. READ NAMEPLATE AND INSTRUCTIONS.

ATTENTION

CHAUD DURANT LE FONCTIONNEMENT. NE TOUCHEZ PAS. 

ÉLOIGNEZ LES ENFANTS, LES VÊTEMENTS ET LES MEUBLES. 

LE CONTACT PEUT CAUSER DES BRÛLURES DE LA PEAU.

LISEZ LA PLAQUE SIGNALÉTIQUE ET LES INSTRUCTIONS

MADE IN CANADA / FAIT AU CANADA

MANUFACTURED BY/ FABRIQUÉ PAR:

FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.

6988 VENTURE ST.

DELTA, BC  V4G 1H4

LISTED SPACE HEATER, SOLID FUEL TYPE,  ALSO 

SUITABLE FOR MOBILE HOME INSTALLATION / 

APPAREIL DE CHAUFFAGE AMBIANT HOMOLOGUÉ 

À COMBUSTIBLE SOLIDE, CONVENANT AUSSI

POUR INSTALLATION DANS UNE MAISON MOBILE 

FLOOR PROTECTION*

PROTECTION DE PLANCHER*

Au Canada, la protection de plancher doit dépasser de 

18 po (457 mm) à l’avant et de 8 po (200 mm) de chaque 
côté du poêle et derrière le 

poêle.

* In Canada, fl oor protection must extend 18" (450mm) 

to the front and 8" (200mm) to each side and back of 

the stove.

DO NOT REMOVE THIS LABEL/

 NE RETIREZ PAS CETTE ÉTIQUETTE

244

INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION AND OPERATING INSTRUCTIONS.  

CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA.  

USE 150 MM (6 IN.) DIAMETER MINIMUM 24 MSG BLACK OR 26 MSG BLUED STEEL CONNECTOR WITH LISTED UL103 HT 

FACTORY-BUILT CHIMNEY SUITABLE FOR USE WITH SOLID FUELS OR MASONRY CHIMNEY.  

SEE LOCAL BUILDING CODE AND MANUFACTURER'S INSTRUCTIONS FOR PRECAUTIONS REQUIRED FOR PASSING A 

CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING.  DO NOT PASS CHIMNEY CONNECTOR THROUGH COMBUSTIBLE 

WALL OR CEILING.  DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.

INSTALLER ET UTILISER SEULEMENT SELON LES INSTRUCTIONS D’INSTALLATION ET D’UTILISATION DU FABRICANT. 

CONTACTER LES RESPONSABLES DU BÂTIMENT OU DU SERVICE-INCENDIE DE VOTRE RÉGION POUR CONNAÎTRE 

LES RESTRICTIONS ET EXIGENCES D’INSPECTION DANS VOTRE RÉGION. UTILISER UN CONNECTEUR D’UN DIAMÈTRE 

MINIMAL DE 150 MM (6 PO) 24 MSG EN ACIER NOIR OU 26 MSG EN ACIER BRONZÉ AVEC CHEMINÉE PRÉFABRIQUÉE 

HOMOLOGUÉE UL103 HT CONÇUE POUR UTILISATION AVEC COMBUSTIBLES SOLIDES OU UNE CHEMINÉE DE MAÇON-

NERIE.

VOIR LE CODE DU BÂTIMENT LOCAL ET LES INSTRUCTIONS DU FABRICANT CONCERNANT LES PRÉCAUTIONS  

EXIGÉES POUR INSTALLER UNE CHEMINÉE TRAVERSANT UN MUR OU PLAFOND EN MATÉRIAUX COMBUSTIBLES. 

NE FAITES PAS TRAVERSER LE CONNECTEUR DE CHEMINÉE DANS UN MUR OU PLAFOND EN MATÉRIAUX COMBUS-

TIBLES. NE RACCORDEZ PAS CE POÊLE À BOIS À UN CONDUIT DE CHEMINÉE DESSERVANT UN AUTRE APPAREIL.

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS

DÉGAGEMENTS MINIMUMS AUX MATÉRIAUX COMBUSTIBLES

F2400M WITH AIRMATE SHIELD

F2400M  WITHOUT AIRMATE SHIELD

RESIDENTIAL INSTALLATION USING

 SINGLE WALL  CONNECTOR

MEASURE 

     

  

      FLUE

FROM  

          HEATER    

       CENTER-LINE

RESIDENTIAL INSTALLATION USING

 SINGLE WALL  CONNECTOR

SIDEWALL 

A 457  mm / 18 in  D 762 mm / 30 in

BACKWALL  B 305  mm / 12 in  E  470 mm / 18.5 in

CORNER 

C 165  mm / 6.5 in  F  457 mm / 18 in

INSTALLATION USING LISTED DOUBLE WALL 

CONNECTOR -  MOBILE HOME 

SIDEWALL 

A 380 mm / 15 in 

D 685 mm / 27 in

BACKWALL  B 165 mm / 6.5 in  E  330 mm / 13 in

CORNER 

C 152 mm / 6  in  F  444 mm / 17.5in

INSTALLATION USING LISTED DOUBLE WALL 

CONNECTOR - RESIDENTIAL CLOSE CLEARANCE

SIDEWALL 

A 380 mm / 15  in  D 685 mm / 27 in

BACKWALL  B 165 mm / 6.5in 

E  330 mm / 13 in

CORNER 

C 152  mm / 6 in 

F  444 mm / 17.5 in

INSTALLATION USING LISTED DOUBLE WALL 

CONNECTOR - ALCOVE

SIDEWALL 

A 406  mm / 16 in  D 711  mm / 28  in

BACKWALL  B 280  mm / 11 in  E  444  mm / 17.5 in

CORNER 

C 152  mm / 6 in 

F  444  mm / 17.5 in

INSTALLATION USING LISTED DOUBLE WALL 

CONNECTOR -  MOBILE HOME 

SIDEWALL 

A 380  mm / 15 in  D 685 mm / 27 in

BACKWALL  B 140  mm / 5.5 in  E 304 mm / 12 in

CORNER 

C 102  mm / 4 in 

F  393 mm / 15.5 in 

SIDEWALL 

A 380 mm / 15  in  D 685 mm / 27 in

BACKWALL  B 140  mm / 5.5 in  E  304 mm / 12 in

CORNER 

C 102  mm / 4 in 

F  393 mm / 15.5 in

INSTALLATION USING LISTED DOUBLE WALL 

CONNECTOR - RESIDENTIAL CLOSE CLEARANCE

INSTALLATION USING LISTED DOUBLE WALL 

CONNECTOR - ALCOVE

SIDEWALL 

G 380 mm / 15 in 

I  685 mm / 27 in

BACKWALL  H 165 mm / 6.5 in  J  330 mm / 13 in

MEASURE 

     

  

      FLUE

FROM  

        HEATER    

       CENTER-LINE

SIDEWALL 

G 380 mm / 15 in 

I  685 mm / 27 in

BACKWALL  H 140 mm / 5.5in 

J  304  mm / 12 in

918-172f

 JAN   FEB   MAR    

APR    MA

 JUN    JUL

   

AUG   SEPT   OCT    NOV     DE

C

DA

TE OF MANUF

ACTURE

2017

2019

2020

2021

2018

SAFETY LABEL FOR F2403M

Содержание F2403M

Страница 1: ...919 044c MODELS F2403M S2403M Freestanding Woodstove 11 08 18 Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions...

Страница 2: ...se contact the REGENCY DEALER in your area Keep those REGENCY FIRES burning SAFETY NOTE If this woodstove is not properly installed a house fire may result For your safety follow the instal lation ins...

Страница 3: ...nstallation 17 Flue Baffle Secondary Air Tube Installation 17 Stainless Steel Smoke Deflector Installation 18 Screen Door 19 Brick Installation 19 Door Handle 19 Glass Installation 19 Step by step Opt...

Страница 4: ...EL 2100 SUPER VENT 2100 SUPERPRO 2100 CF SENTINAL AUX TATS UNIS CONNECTEURS DE CHEMIN E HOMOLOGU S DOUBLE PAROI SECURITY MOD LE DP SELKIRK MODEL DS OLIVER MACLEOD PRO VENT PV SIMPSON DURA VENT MOD LE...

Страница 5: ...SUPER VENT 2100 SUPERPRO 2100 CF SENTINAL AUX TATS UNIS CONNECTEURS DE CHEMIN E HOMOLOGU S DOUBLE PAROI SECURITY MOD LE DP SELKIRK MODEL DS OLIVER MACLEOD PRO VENT PV SIMPSON DURA VENT MOD LE DVL GSW...

Страница 6: ...NSIONS UNIT DIMENSIONS 24 610mm 30 3 8 772mm 29 1 8 740mm 27 3 8 695mm 24 7 8 632mm 6 5 8 168mm 6 5 8 152mm 24 7 8 609mm 24 609mm 27 3 8 685mm To Ash Lip 29 1 8 736mm 32 1 4 819mm 34 3 8 873mm 6 152mm...

Страница 7: ...standing Woodstove 7 DIMENSIONS WOOD STOVE OUTSIDE AIR DIMENSIONS With pedestal from base of unit to centerline 4 1 2 114mm With bottom heat shield from rear heat shield to centerline 6 3 4 171mm Rear...

Страница 8: ...ng the bolt down holes inside the pedestal the same ones used in Mobile Home installations 11 For residential installations using 6 C Vent single wall the chimney connector must be at least 24 gauge s...

Страница 9: ...mate 15 381 mm 5 5 139 mm 4 101 mm 27 685 mm 12 304 mm 15 5 393 mm with Rear Deflector 15 381 mm 6 5 165 mm 6 152 mm 27 685 mm 13 330 mm 17 5 444 mm Medium S 2403M Step Stove 15 381 mm 5 5 139 mm 4 10...

Страница 10: ...M 36 914 mm Step Stove S 2403M 36 914 mm Minimum Overall Depth Y of Floor Protector Residential Residential Mobile Home Alcove Unit C Vent Close Clearance Close Clearance Y Z Y Z Y Z Y Z Medium F2403M...

Страница 11: ...of the rear heat shield as shown in Diagram 4 Side Shield Adjustment The left and right side shields are lowered for shipping and handling It allows for a handhold on the top of the stove Before plac...

Страница 12: ...n decrease problems such as difficult start ups back smoking when door is open and dirty glass It might be sufficient to initially try with the minimum re quired height and then if problems do arise a...

Страница 13: ...r safety and proper draft operation MASONRY CHIMNEY Ensure that a masonry chimney meets the mini mum standards of the National Fire Protection Association NFPA by having it inspected by a professional...

Страница 14: ...ey clearance to brick and combustibles 2 in 50 8mm Minimum clearance 12 in 304 8mm of brick Chimney connector Fire clay liner Method C 6 152 4 mm Clearance to Combustible Wall Member Starting with a m...

Страница 15: ...le b 0 18 21 1000 18 72 21 84 2000 19 44 22 68 5000 21 60 25 20 8000 23 76 27 72 TABLE 1 MINIMUM RECOMMENDED FLUE HEIGHTS IN FEET Measured from the top of the unit OF ELBOWS ELEVATION FT ABOVE SEA LEV...

Страница 16: ...assis of the Mobile Home 4 A listed double wall connector chimney system roof thimble spark arrestor and roof flashing kit suitable for use in Mobile Homes must be used 5 If the chimney exits the Mobi...

Страница 17: ...the firebox 1 If all 4 air tubes are installed continue on to Step 2 if not follow the instructions below Install the air tube into the holes in the side channels The notch goes on the right hand sid...

Страница 18: ...s To replace the deflector loosen off both bolts and slide defector upward and out Install new defector and hand tighten bolts Ensure positive location of the deflector prior to hand tightening WARNIN...

Страница 19: ...boltsholdingthe2platestogetherfrominside the firebox 4 Push the ash plug into the hole inside the firebox and replace all the bricks except for the brick over the ash plug refer to the brick diagram i...

Страница 20: ...h Black Black High Black Low Red Black Fan Thermodisc normally open 120V AC 60 Hz Blower Fan Wiring Diagram Wire98gr eps updated Jan 27 00 updated Aug 09 05 capitalized the word Nut Lockwasher Ground...

Страница 21: ...and avoid a large fire Only after 5 or 6 such fires can you operate the stove at its maximum setting and only after the metal has been warmed 7 For the first few days the stove will give off an odour...

Страница 22: ...nt ash dump for easy removal of ash refer to Modular Installation Options section Safety Precautions 1 Do not allow ashes to build up to the loading doors Onlyremoveasheswhenthefirehas died down Even...

Страница 23: ...creosote deposits may build up rapidly Moving parts of your stove require no lubrication 5 Thechimneyandchimneyconnectorshould beinspectedatleastonceeverytwomonths during the heating season to determ...

Страница 24: ...per Test Test the seal on the loading door with a paper bill Place a paper bill in the gasketed area of the door of a cold stove Close the door Try to remove the paper by pulling The paper should not...

Страница 25: ...te 13 Bolt 1 4 20 x 1 2 Hex Head 14 820 376 Retainer Plate Ash Dump Top 15 Nut 1 4 20 Hex 16 846 570 7 8 Door Gasket Repair Kit 17 846 918 Hinge Cap Gold 2 set 948 079 Spring Hinge Cap Nickel each 19...

Страница 26: ...Door Gasket Repair Kit 17 846 918 Hinge Caps Gold 2 set 948 079 Spring Hinge Cap Nickel each 19 948 101 Spring Handle Large Gold 948 135 Spring Handle Large Nickel 20 948 102 Spring Handle Small Gold...

Страница 27: ...249 Ash Plug Tool Handle 56 020 911 Bottom Shield Medium 57 Blanking Plate Btm Shield 850 101 Ashdrawer Kit Btm Shield 55 Ashdrawer Bottom Shield 58 942 110 Ash Plug 59 820 249 Ash Plug Tool Handle 14...

Страница 28: ...stove PARTS LIST Part Description 020 960 Brick Set Complete 70 902 111 Brick Regular Full Size 1 1 4 x 4 1 2 x 9 74 Brick Partial 1 1 4 x 4 1 2 x 3 1 2 75 Brick Partial 1 1 4 x 4 1 2 x 2 76 Brick Par...

Страница 29: ...Regency Freestanding Woodstove 29 NOTES...

Страница 30: ...r wiring switches etc 2 Glass Crazing 1 Catalyst Assembly 6 Years Prorated Venting Chimney 1 Screens 1 Conditions Warranty protects against defect in manufacture or FPI factory assembled components on...

Страница 31: ...ze or type operator error abuse misuse use of improper fuels such as unseasoned cordwood mill ends construction lumber or debris off cuts treated or painted lumber metal or foil plastics garbage solve...

Страница 32: ...des for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain warranty service In the event the auth...

Страница 33: ...rder for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Detail...

Страница 34: ......

Страница 35: ......

Страница 36: ...tion Dealer Name Address _______________________________________________ ___________________________________________________________________ Installer _________________________________________________...

Отзывы: