Regency Fireplace Products F2403M Скачать руководство пользователя страница 23

Regency Freestanding Woodstove

23

MAINTENANCE

CREOSOTE

When wood is burned slowly, it produces tar and 

other organic vapours, which when combined 

with moisture, form creosote. The creosote va-

pours condense in the relatively cool chimney 

flue of a slow burning fire. As a result, creosote 

residue accumulates on the flue lining.  When 

ignited, this creosote can result in an extremely 

hot fire.

WARNING:  Things to remember in case 

of a chimney fire:

1. Close all draft and damper controls.

2. CALL THE FIRE DEPARTMENT.

Ways to Prevent and Keep Unit 

Free of Creosote

1) 

Burn stove with the draft control wide open 

for about 10-15 minutes every morning 

during burning season.

2) 

Burn stove with draft control wide open 

for about 10 - 15 minutes every time you 

apply fresh wood. This allows the wood to 

achieve the charcoal stage faster and burns 

up any unburned gas vapours which might 

otherwise be deposited within the system.

3)  Only burn seasoned wood!

  Avoid burning 

wet or green wood. Seasoned wood has 

been dried at least one year.

4) 

A  small  hot  fire  is  preferable  to  a  large 

smouldering one that can deposit creosote 

within the system.

WOOD STORAGE

Store wood under cover, such as in a shed, or 

covered with a tarp, plastic, tar paper, sheets 

of scrap plywood, etc., as uncovered wood can 

absorb water from rain or snow, delaying the 

seasoning process.

MAINTENANCE

It is very important to carefully maintain your 

fireplace  stove,  including  burning  seasoned 

wood and maintaining a clean stove and chim-

ney system. Have the chimney cleaned before 

the burning season and as necessary during 

the season, as creosote deposits may build up 

rapidly. Moving parts of your stove require no 

lubrication.

 

5) 

The chimney and chimney connector should 

be inspected at least once every two months 

during the heating season to determine is a 

creosote buildup has occured.

6)

 

Have chimney system and unit cleaned 

by competent chimney sweeps twice a 

year during the first year of use and at 

least once a year thereafter or when a 

significant layer of creosote has accu-

mulated (3 mm/1/8" or more) it should be 

removed to reduce the risk of a chimney 

fire. 

MAINTENANCE OF 

GOLD-PLATED DOORS

The gold electroplated finish on the door requires 

little maintenance, and need  only be cleaned 

with a damp cloth. DO NOT use abrasive ma-

terials or chemical cleaners, as they may harm 

the finish and void the warranty.

LATCH ADJUSTMENT

The door latch may require adjustment as the 

door gasket material compresses after a few 

fires.  Removal of the spacer washer, shown 

in the diagram below, will allow the latch to be 

moved closer to the door frame, causing a tighter 

seal.  Remove and replace the nuts, washer and 

spacer as shown.

 

DOOR GASKET

If the door gasket requires replacement 7/8" diam-

eter material must be used. Regency uses AMATEX 

# 10-863KR 7/8" dia. gasket (Part #846-570). A 

proper high temperature gasket adhesive is 

required.  See your Regency Dealer.

 

GLASS MAINTENANCE

Your Regency stove is supplied with 5 mm 

Neoceram ceramic glass (Part #846-302) that 

will withstand the highest heat that your unit will 

produce.  In the event that you break your glass 

by impact, purchase your replacement from an 

authorized Regency dealer only, and follow our 

step-by-step instructions for replacement (refer 

to Glass Installation section).

Allow the stove to cool down before cleaning 

the glass, do not clean the glass when it is hot. 

Do not use abrasive cleaners.

 

Содержание F2403M

Страница 1: ...919 044c MODELS F2403M S2403M Freestanding Woodstove 11 08 18 Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions...

Страница 2: ...se contact the REGENCY DEALER in your area Keep those REGENCY FIRES burning SAFETY NOTE If this woodstove is not properly installed a house fire may result For your safety follow the instal lation ins...

Страница 3: ...nstallation 17 Flue Baffle Secondary Air Tube Installation 17 Stainless Steel Smoke Deflector Installation 18 Screen Door 19 Brick Installation 19 Door Handle 19 Glass Installation 19 Step by step Opt...

Страница 4: ...EL 2100 SUPER VENT 2100 SUPERPRO 2100 CF SENTINAL AUX TATS UNIS CONNECTEURS DE CHEMIN E HOMOLOGU S DOUBLE PAROI SECURITY MOD LE DP SELKIRK MODEL DS OLIVER MACLEOD PRO VENT PV SIMPSON DURA VENT MOD LE...

Страница 5: ...SUPER VENT 2100 SUPERPRO 2100 CF SENTINAL AUX TATS UNIS CONNECTEURS DE CHEMIN E HOMOLOGU S DOUBLE PAROI SECURITY MOD LE DP SELKIRK MODEL DS OLIVER MACLEOD PRO VENT PV SIMPSON DURA VENT MOD LE DVL GSW...

Страница 6: ...NSIONS UNIT DIMENSIONS 24 610mm 30 3 8 772mm 29 1 8 740mm 27 3 8 695mm 24 7 8 632mm 6 5 8 168mm 6 5 8 152mm 24 7 8 609mm 24 609mm 27 3 8 685mm To Ash Lip 29 1 8 736mm 32 1 4 819mm 34 3 8 873mm 6 152mm...

Страница 7: ...standing Woodstove 7 DIMENSIONS WOOD STOVE OUTSIDE AIR DIMENSIONS With pedestal from base of unit to centerline 4 1 2 114mm With bottom heat shield from rear heat shield to centerline 6 3 4 171mm Rear...

Страница 8: ...ng the bolt down holes inside the pedestal the same ones used in Mobile Home installations 11 For residential installations using 6 C Vent single wall the chimney connector must be at least 24 gauge s...

Страница 9: ...mate 15 381 mm 5 5 139 mm 4 101 mm 27 685 mm 12 304 mm 15 5 393 mm with Rear Deflector 15 381 mm 6 5 165 mm 6 152 mm 27 685 mm 13 330 mm 17 5 444 mm Medium S 2403M Step Stove 15 381 mm 5 5 139 mm 4 10...

Страница 10: ...M 36 914 mm Step Stove S 2403M 36 914 mm Minimum Overall Depth Y of Floor Protector Residential Residential Mobile Home Alcove Unit C Vent Close Clearance Close Clearance Y Z Y Z Y Z Y Z Medium F2403M...

Страница 11: ...of the rear heat shield as shown in Diagram 4 Side Shield Adjustment The left and right side shields are lowered for shipping and handling It allows for a handhold on the top of the stove Before plac...

Страница 12: ...n decrease problems such as difficult start ups back smoking when door is open and dirty glass It might be sufficient to initially try with the minimum re quired height and then if problems do arise a...

Страница 13: ...r safety and proper draft operation MASONRY CHIMNEY Ensure that a masonry chimney meets the mini mum standards of the National Fire Protection Association NFPA by having it inspected by a professional...

Страница 14: ...ey clearance to brick and combustibles 2 in 50 8mm Minimum clearance 12 in 304 8mm of brick Chimney connector Fire clay liner Method C 6 152 4 mm Clearance to Combustible Wall Member Starting with a m...

Страница 15: ...le b 0 18 21 1000 18 72 21 84 2000 19 44 22 68 5000 21 60 25 20 8000 23 76 27 72 TABLE 1 MINIMUM RECOMMENDED FLUE HEIGHTS IN FEET Measured from the top of the unit OF ELBOWS ELEVATION FT ABOVE SEA LEV...

Страница 16: ...assis of the Mobile Home 4 A listed double wall connector chimney system roof thimble spark arrestor and roof flashing kit suitable for use in Mobile Homes must be used 5 If the chimney exits the Mobi...

Страница 17: ...the firebox 1 If all 4 air tubes are installed continue on to Step 2 if not follow the instructions below Install the air tube into the holes in the side channels The notch goes on the right hand sid...

Страница 18: ...s To replace the deflector loosen off both bolts and slide defector upward and out Install new defector and hand tighten bolts Ensure positive location of the deflector prior to hand tightening WARNIN...

Страница 19: ...boltsholdingthe2platestogetherfrominside the firebox 4 Push the ash plug into the hole inside the firebox and replace all the bricks except for the brick over the ash plug refer to the brick diagram i...

Страница 20: ...h Black Black High Black Low Red Black Fan Thermodisc normally open 120V AC 60 Hz Blower Fan Wiring Diagram Wire98gr eps updated Jan 27 00 updated Aug 09 05 capitalized the word Nut Lockwasher Ground...

Страница 21: ...and avoid a large fire Only after 5 or 6 such fires can you operate the stove at its maximum setting and only after the metal has been warmed 7 For the first few days the stove will give off an odour...

Страница 22: ...nt ash dump for easy removal of ash refer to Modular Installation Options section Safety Precautions 1 Do not allow ashes to build up to the loading doors Onlyremoveasheswhenthefirehas died down Even...

Страница 23: ...creosote deposits may build up rapidly Moving parts of your stove require no lubrication 5 Thechimneyandchimneyconnectorshould beinspectedatleastonceeverytwomonths during the heating season to determ...

Страница 24: ...per Test Test the seal on the loading door with a paper bill Place a paper bill in the gasketed area of the door of a cold stove Close the door Try to remove the paper by pulling The paper should not...

Страница 25: ...te 13 Bolt 1 4 20 x 1 2 Hex Head 14 820 376 Retainer Plate Ash Dump Top 15 Nut 1 4 20 Hex 16 846 570 7 8 Door Gasket Repair Kit 17 846 918 Hinge Cap Gold 2 set 948 079 Spring Hinge Cap Nickel each 19...

Страница 26: ...Door Gasket Repair Kit 17 846 918 Hinge Caps Gold 2 set 948 079 Spring Hinge Cap Nickel each 19 948 101 Spring Handle Large Gold 948 135 Spring Handle Large Nickel 20 948 102 Spring Handle Small Gold...

Страница 27: ...249 Ash Plug Tool Handle 56 020 911 Bottom Shield Medium 57 Blanking Plate Btm Shield 850 101 Ashdrawer Kit Btm Shield 55 Ashdrawer Bottom Shield 58 942 110 Ash Plug 59 820 249 Ash Plug Tool Handle 14...

Страница 28: ...stove PARTS LIST Part Description 020 960 Brick Set Complete 70 902 111 Brick Regular Full Size 1 1 4 x 4 1 2 x 9 74 Brick Partial 1 1 4 x 4 1 2 x 3 1 2 75 Brick Partial 1 1 4 x 4 1 2 x 2 76 Brick Par...

Страница 29: ...Regency Freestanding Woodstove 29 NOTES...

Страница 30: ...r wiring switches etc 2 Glass Crazing 1 Catalyst Assembly 6 Years Prorated Venting Chimney 1 Screens 1 Conditions Warranty protects against defect in manufacture or FPI factory assembled components on...

Страница 31: ...ze or type operator error abuse misuse use of improper fuels such as unseasoned cordwood mill ends construction lumber or debris off cuts treated or painted lumber metal or foil plastics garbage solve...

Страница 32: ...des for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain warranty service In the event the auth...

Страница 33: ...rder for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Detail...

Страница 34: ......

Страница 35: ......

Страница 36: ...tion Dealer Name Address _______________________________________________ ___________________________________________________________________ Installer _________________________________________________...

Отзывы: