background image

20

 | 

Regency U31-10 Gas Fireplace Insert

 | 

20

installation

FLUSH LOUVER  

INSTALLATION

1.

  The Top Louver is held in place by friction 

fit, if the Louver needs to be adjusted; bend 
the bracket out as shown in the diagram. 

2.

  Install the Spring Hinges on the left and right 

side of the bottom of the Firebox using 2 screws 
per hinge.

Bottom Louver

Hinge

Location

3.

  Place the Bottom Louver near the hinge. Flip 

hinge over the Bottom Louver and secure using 
3 screws.

FLUSH  GLASS  

INSTALLATION

1)  

Install upper and lower trim.

2)

  Slide the glass into the bottom glass support  

and  secure  with  the  glass  clips  using  the  2 
phillips head screws at the top.

Note:   To  re-install  the  glass,  reverse  the 

 

procedure.

WARNING

The use of substitute glass will void all product warranties.

Do not operate the appliance if the glass panel(s) are removed, cracked or broken. 

 

Replacement of the glass panel(s) should be done by a qualified service person.

Lower Trim

Upper Trim

Содержание Energy U31-LP10

Страница 1: ......

Страница 2: ...mmable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Leave the building immediately Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department...

Страница 3: ...armth and charm of a fireplace at the flick of a switch The models U31 NG10 and U31 LP10 of this series have been approved by Warnock Hersey Intertek for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourself with these instructions and the many feature...

Страница 4: ...ion 13 High elevation 13 Draft hood connection 13 Venting 13 Gas pressure test 13 Gas insert aeration system 14 Test for flue spillage 14 Optional brick panel 14 Log set installation 15 Wiring diagram 18 Standard faceplate hearth trim install 19 Flush louver installation 20 Low profile faceplate installation 21 Safety screen installation removal 23 Optional wall thermostat 24 Final check 24 Operat...

Страница 5: ...4 Regency U31 10 Gas Fireplace Insert 4 dimensions UNIT DIMENSIONS WITH STANDARD FACE PLATE ...

Страница 6: ...Regency U31 10 Gas Fireplace Insert 5 5 dimensions UNIT DIMENSIONS WITH LOW PROFILE FACE PLATE ...

Страница 7: ...ssachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with battery back up in the same room where the gas appliance is installed This is a copy of the labels that accompany each U31 10 Gas Insert We have printed a copy of the contents here for your review The safety label is located on a plate inside the base of the unit visible when the bottom...

Страница 8: ...tly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspecti...

Страница 9: ...SHOULD BE CARE FULLY SUPERVISED WHENTHEY ARE IN THE SAME AREA AS THE APPLI ANCE TODDLERS YOUNG CHILDREN AND OTHERS MAY BE SUSCEPTIBLE TO ACCIDENTAL CONTACT BURNS A PHYSICALBARRIERSISRECOMMEND ED IFTHERE ARE AT RISK INDIVIDUAL INTHE HOUSE TO RESTRICT ACCESS TO A FIREPLACE OR STOVE INSTALL AN ADJUSTABLE SAFETY GATE TO KEEP TODDLERS YOUNG CHILDREN ANDOTHERATRISKINDIVIDUALSOUT OF THE ROOM AND AWAY FRO...

Страница 10: ... fireplace chimney must be cleanandingoodworkingorderandconstructed of non combustible materials 6 The chimney cleanouts must fit properly 7 Refractory firebricks glassdoors screenrails screen mesh and log grates can be removed from the fireplace before installing the gas fireplace insert 8 Smoke shelves shields and baffles may be removed if attached by mechanical fasteners If any part is removed ...

Страница 11: ... is firing correctly This includes a Clocking the appliance to ensure the correct firing rate b Adjusting the primary air if required to ensure that the flame does not carbon c Ensuring that the appliance is venting correctly MATERIALS REQUIRED No electrical power supply is required for the gas control to operate A 120 Volt AC power cord is hooked up to the fan Plug the 3 wire cord into a suitable...

Страница 12: ...s Fireplace Insert 11 11 installation COMBUSTIBLE MANTEL CLEARANCES IN MASONRY INSTALLATION Clearances for Low Profile Faceplate with Safety Screen Clearances for Standard Faceplate Contour Faceplate with Safety Screen ...

Страница 13: ...the pilot cap to expose the pilot orifice 18 Unscrew the pilot orifice with the allen key and replace with the LP pilot orifice in the kit 19 Replace Burner Tray and reverse steps 5 to 1 20 Adjust the burner aeration setting to 3 8 to 3 8 as required for the best flame picture Fig 1 9 R e m o v e t h e b l a c k protection cap by hand fromthehi lowknob Fig 1 Fig 2 12 Flip the screw Fig 3 Fig 4 Fig...

Страница 14: ...gh the front of the unit therefore the front of the unit must be kept clear of any obstructions GAS PRESSURE TEST Theunitispresettogivethecorrectgasinputatthe specified manifold pressures shown on the label The maximum gas manifold pressure is Natural Gas 3 5 w c Propane 10 w c The manifold pressure is controlled by a regulator built into the gas control and should be checked at the pressure test ...

Страница 15: ...he home and then close all external doors and windows in the house 2 Light the unit and set controls to maximum Turn fan off 3 After five minutes test that there is a pull on the flue by placing a smoke match cigarette or similar device which gives off smoke in front of the spill tube To ensure a valid test place a scrap piece of sheet metal or other noncombustible material between the spill tube ...

Страница 16: ...2 154 Embers i 902 153 Rockwool j 902 179 P Vermiculite k 946 669 Platinum Embers supplied with packaged manual Note Install Optional Brick Panels prior to installing logs 1 Carefully remove the logs from the box and unwrap them The logs are fragile handle with care do not force into position 2 Sprinkle the vermiculite around the firebox base Take some of the embers approx 1 3 of the bag and sprin...

Страница 17: ...Center Log E 02 47 over Log B 02 45 and across the cutout on Log A 02 43 Cutout Pin Cutout Notch 8 Position notch in Front Right Log F 02 48 on Log E 02 47 and push the bottom right edge against the bracket on the burner tray and the front edge of the rear burner Notch Bracket D 02 46 E 02 47 F 02 48 C 02 56 A 02 43 B 02 45 A 02 43 B 02 45 E 0 2 4 7 Logs A 02 43 C 02 56 and B 02 45 in position C 0...

Страница 18: ...u t t nug aga n t t e bracket and t e front edge of t e rear burner Side View Page 3 of 3 11 Separate platinum embers and place on and around the embers and rockwool on the burner tray oid stacking platinum embers 12 est re to ensure proper light off makesure ame ows smoothly from one end of burner to the other f there is any ame hesitation check that area for any blockage of the burner port The 0...

Страница 19: ... Label all wires prior to disconnection when servic ing controls Wiring errors can cause improper and dangerous operation WARNING Electrical Grounding Instructions This appliance is equipped with a three pronged grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Do not cut or remove the grounding prong from this pl...

Страница 20: ...aceplate side panels with the screws provided See Diagram 1 3 Using the connectors provided join the left side trim with the ON OFF switch to the top trim Diagram 2 Connect the right side trim to the top trim 4 Place the trim on the assembled faceplate panels aligning the wire connections from the switches with the notch on the left side panel 5 Connect the fan switch wires by taking the black and...

Страница 21: ...tom Louver near the hinge Flip hinge over the Bottom Louver and secure using 3 screws FLUSH GLASS INSTALLATION 1 Install upper and lower trim 2 Slide the glass into the bottom glass support and secure with the glass clips using the 2 phillips head screws at the top Note To re install the glass reverse the procedure WARNING The use of substitute glass will void all product warranties Do not operate...

Страница 22: ...am 5 Diagram 6 3 Tuck the wires into the clip to keep them away from the insert using the clip provided Attach the clip to the rear of the faceplate to en sure that the wires do not touch the side of the unit The power cord should be run behind the inner faceplate panel 4 Install the on off switch fan speed control box to the left hand bottom leg of the inner faceplate Controls located on the left...

Страница 23: ...anel pins 11 Install safety screen see next page 9 Hook door frame on 2 pins over glass door in locations shown below in Diagram 10 7 Attach 2 brackets near the bottom of the unit with one screw as shown below in Diagram 8 left and right brackets are inter changeable 8 Attach Regency logo to bottom louver Install bottom louver by hanging louver on brackets installed in step 8 Final Install Diagram...

Страница 24: ...on the safety screen into the slots on the unit 3 To remove lift screen assembly up and pull away from unit Note If the top and bottom glass trim supplied with the optional flush louvers is installed discard and recycle the glass trim as this not required when using the safety screen This is only used on previous models of fireplaces which do not use this optional safety screen ...

Страница 25: ... on label at 15 minutes 2 If required adjusting the primary air to ensure that the flame does not carbon First allow the unit to burn for 15 min to stabilize CAUTION Any alteration to the product that causes soot ing or carboning that results in damage to the exterior facia is not the responsibility of the manufacturer Thermostat Wire Table Recommended Maximum Lead Length Two Wire When Using Wall ...

Страница 26: ...tacts closing and is normal Pilot Flame While the pilot flame is on it can make a very slight whisper sound Gas Control Valve As the gas control valve turns ON and OFF a dull clicking sound may be audible this is normal operation of a gas regulator or valve Unit Body Firebox Different types and thicknesses of steel will expand and contract at different rates resulting in some cracking and ticking ...

Страница 27: ...ment de modification de service ou d entretien peut provoquer des blessures ou des dommages matéri els Reportez vous au manuel du propriétaire de l information fournie avec cet appareil Pour obtenir de l aide ou des informations supplé mentaires consulter un installateur qualifié une agence de service ou fournisseur de gaz Important If the pilot does not hold turn pilot knob to OFF position Wait 5...

Страница 28: ...ck the pilot 5 Keep the area near the appliance clear and free from combustible materials gasoline and other flammable vapours and liquids 6 Each time the appliance is lit it may cause condensation and fog the glass This con densation and fog is normal and will disap pear in a few minutes as the glass heats up Never operate the appliance without the glass properly secured in place with broken glas...

Страница 29: ...bit of dish soap on the grommet so it will slide more easily onto the pin Check to make sure the fan is seated properly on the pins this is very important try to move the fan back and forth there should be no noise if there is check that the grommets haven t come loose When replacing the Burner Tray slide the aeration adjustment rod through the opening in the front of the Valve Assembly 1 Turn the...

Страница 30: ...ket 59 936 233 3 4 Rope Gasket 404 969 Conversion to LP Kit 919 435 Manual Not available as a replacement part Part Description 1 400 011 Fan Opening Cover 2 911 071 P Fan Motor 120 V 5 910 750 Power Cord 120 V 910 752 Wire Harness intermediate 6 Thermodisc cover 7 Thermodisc bracket 8 910 142 Thermodisc Fan Auto ON OFF 10 Drafthood Assembly 11 Spill Switch Bracket 12 910 220 Spill Switch 13 Level...

Страница 31: ...urner Assembly NG LP 63 910 048 Pilot Assembly NG 4 flame convertible top 910 049 Pilot Assemby LP 4 flame convertible top 67 Firebox Base 69 402 935 Log Set 402 572 Ember Package 70 Air Channel 72 Glass Trim Retainer 73 Firebox back and top 74 Glass Gasket Retainer 75 404 050 Firebox Baffle 76 400 090 Brick Clip 77 404 005 Fan Access Plate 78 400 023 Thermodisc Bracket 79 400 068 Thermodisc cover...

Страница 32: ...05 900 Description Standard Faceplate Assembly Part 405 919 Description Oversize Faceplate Assembly 1 2 4 3 5 LOW PROFILE FACEPLATE Part 403 954 Description Low Profile Faceplate 1 Back plate Assembly 2 Bottom Louver 3 Right mounting bracket 4 Left mounting bracket 5 Front Frame ...

Страница 33: ...32 Regency U31 10 Gas Fireplace Insert 32 notes ...

Страница 34: ...Regency U31 10 Gas Fireplace Insert 33 33 notes ...

Страница 35: ...34 Regency U31 10 Gas Fireplace Insert 34 notes ...

Страница 36: ...ent parts and issue credit once the replaced component has been returned to Regency and evalu ated for manufacturer defect The authorized selling dealer is responsible for all in field service work carried out on your Regency product Regency will not be liable for results or costs of workmanship from unauthorized service persons or dealers At all times Regency reserves the right to inspect product...

Страница 37: ...___________________________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial No ___________________________________________________________ Register your Regency warranty online www regency fire com Reasons to register your product online today View and modify a list of all your ...

Отзывы: