background image

PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE 

REFERENCE

Models: DVi34LNG

  

DVi34LLPG

 DVi34LULPG

Owners &
Installation

 

Man

ual

06/05/20

LISTINGS AND CODE APPROVALS

These gas appliances have been tested in 

accordance with AS/NZS 5263.0 & AS/NZS 

5263.1.3  and  have  been  certified  by  the 

Australian Gas Association for installation and 

operation as described in these Installation 

and Operating Instructions. Must be installed 

as per AS/NZS5601. 

Your unit should be serviced annually by 

an authorised service person.

920-236b

DVi34L GAS INBUILT

FOR YOUR SAFETY

What to do if you smell gas:

 

Do not try to light any appli-

ance

  Do not touch any electri-

cal switch: do not use any 

phone in your building.

  Immediately call your gas 

supplier from a neighbour's 

phone. Follow the gas sup-

plier's instructions.

  If you  cannot reach your 

gas  supplier,  call  the  fire 

department.

WARNING:  

Improper installation, adjustment, altera-

tion, service or maintenance can cause 

injury or property damage. Refer to this 

manual. For assistance or additional in-

formation consult an authorised installer, 

service agency or the gas supplier.
FOR YOUR SAFETY

Do not store or use gasoline or other flam

-

mable vapours and liquids in the vicinity of 

this or any other appliance.
Installation and service must be performed 

by an authorised installer, service agency or 

the gas supplier.

Содержание DVi34L Series

Страница 1: ...mell gas Do not try to light any appli ance Do not touch any electri cal switch do not use any phone in your building Immediately call your gas supplierfromaneighbour s phone Follow the gas sup plier s instructions If you cannot reach your gas supplier call the fire department WARNING Improper installation adjustment altera tion service or maintenance can cause injury or property damage Refer to t...

Страница 2: ...hould turn off 10 Wait approx 30 seconds turn the on again check all the functions work fan speed can be adjusted flame height can be adjusted etc Note To view a step by step pairing video please visit regency fire com au Customer Care Fireplace Care Videos Note The Remote Control Handset has a set of unique ID codes that is pre programmed into its memory This set of ID codes helps to differen tia...

Страница 3: ...TO A THIRD PARTY WITHOUT OUR PRIOR WRITTEN CONSENT CURRENT REVISION PREVIOUS REVISION PART MAT L ANGULAR INSIDE BEND RADII UNITS IN INCHES DIMENSIONS TOLERANCES UNLESS OTHERWISE STATED SCALE DO NOT PROJECTION 3RD ANGLE MODEL QTY REV 1 0 031 PART NO FIREPLACE PRODUCTS INTERNATIONAL 7 4 2019 SEE ABOVE SHEAR PUNCH FORM 337 500 PY 337 500 DVi34 GAS INSERT 1 12 680 324 565 401 52 576 555 909 640 733 74...

Страница 4: ...O A THIRD PARTY WITHOUT OUR PRIOR WRITTEN CONSENT CURRENT REVISION PREVIOUS REVISION PART MAT L ANGULAR INSIDE BEND RADII UNITS IN INCHES DIMENSIONS TOLERANCES UNLESS OTHERWISE STATED SCALE DO NOT PROJECTION 3RD ANGLE MODEL QTY REV 1 0 031 PART NO FIREPLACE PRODUCTS INTERNATIONAL 7 4 2019 SEE ABOVE SHEAR PUNCH FORM 337 500 PY 337 500 DVi34 GAS INSERT 1 12 680 324 555 909 640 733 744 565 401 52 576...

Страница 5: ...from NG to Propane ULPG 13 Log Set Installation 14 Glass Door installation 18 Faceplate Safety Screen Installation 19 Optional Spacer Installation 20 Final Check 21 Wiring 21 OPERATING INSTRUCTIONS Operating Instructions 22 Lighting Instructions 22 Shutdown Instructions 22 First Fire 22 Remote Control 22 Summary of Controls 22 Fan Operation 22 Adjusting Flame Height 22 Copy Of Lighting Instruction...

Страница 6: ...E ULPG Model DVi34LNG DVi34LLP DVi34LULPG Gas Consumption High 31 7 MJ h 30 6 MJ h 26 4 MJ h Gas Consumption Low 21 1 MJ h 25 1 MJ h 20 9 MJ h Min Supply Pressure 1 13 kPa 2 75 kPa 2 75 kPa Manifold Pressure High 0 87 kPa 2 51 kPa 2 51 kPa Manifold Pressure Low 0 40 kPa 1 6 kPa 1 6 kPa Injector Size 1 x 37 1 x 52 1 x 53 2 64 mm 1 61 mm 1 51 mm Model Approval No AGA 7469 G SUITABLE ONLY FOR INDOOR ...

Страница 7: ...assremovedforservicingmust bereplacedpriortooperatingtheappliance 8 To prevent injury do not allow anyone who is unfamiliar with the operation to use the fireplace MATERIALSREQUIRED A 240 Volt AC power cord is hooked up to the unit Plug 3 wire cord into a suitable receptacle Do not cut the ground terminal off under any circumstances When connected with 240 volts the appliance must be electrically ...

Страница 8: ...0 406 600 Fascia with spacer 223 586 680 353 600 Lintel depth A Height B Width Front C Depth D Width Back E Fascia flush 273 586 780 406 600 Fascia With Spacer 223 586 680 353 600 Minimum fireplace Opening Date 21 11 2019 MINIMUM FIREPLACE OPENING The minimum fireplace openings for the Regency DVi34L gas space heater are shown below INSTALLATION ...

Страница 9: ...ll pass through the chimney above the appliance Move the appliance into the exact location where it is to be installed Ensure that the Insert is level INSTALLATION 305 mm Mantel 89 mm Mantel 535 mm 610 mm to floor Top Faceplate 51 0 305 152 102 203 254 51 0 305 152 406 102 356 203 457 254 Side View 330 mm 508 559 Mantel Clearances Note A non combustible mantel may be installed at a lower height if...

Страница 10: ...hten S I T Valve Description 1 On Off Solenoid Valve EV1 2 On Off Solenoid Valve EV2 3 Inlet Pressure Test Point 4 Outlet Pressure Test Point 5 Connection for Pressure Regulator Combustion Chamber Compensation 6 Pressure Regulator for Minimum and Maximum Outlet Pressure 7 Gas Outlet Pressure Electric Modulator 8 Pilot Outlet 9 Main Gas Outlet 10 Side Outlet FLUE LINER INSTALLATION 1 Cut the flex l...

Страница 11: ...te over the tow ends of the Flex Liner and secure it to the sur rounding masonry using masonry anchor bolts Before installing the baseplate run a bead of non hardening seal and between the Baseplate and the masonry to prevent moisture from entering the chimney Note Verify that there is sufficient room to mount the Baseplate on to the masonry You must have a level surface in order to install the Ba...

Страница 12: ...T covered under warranty INSTALLATION DVi34LNG For 0 to 610 meters altitude DVi34LLPG For 0 to 610 meters altitude DVi34LULPG For 0 to 610 meters altitude Burner Inlet Orifice Sizes NG Propane ULPG Burner 37 52 53 Max Input NG 31 7 MJ h Propane 30 6 MJ h ULPG 26 4 MJ h Min Input NG 21 1 MJ h Propane 25 1 MJ h ULPG 20 9 MJ h Supply Pressure NG 1 13 kPa Propane 2 75 kPa ULPG 2 75 kPa Manifold Pressu...

Страница 13: ...rifice with a 1 2 wrench and discard Use a wrench to hold on to the elbow behind the orifice Control Box Cover Antenna Jumper Location 16 Remove the jumper using a plier 7 Reinstall new burner orifice Propane stamped 52 OR ULPG stamped 53 and tighten 8 Apply the conversion label This unit has been converted to ULPG over top of the serial number decal 12 Replace the black NATURAL GAS label with eit...

Страница 14: ...ation of flame control 23 Check for proper flame appearance and glow on logs C B A 18 Turn on gas supply and plug in power cord 19 Adjusting the Outlet Pressure All the adjustments must be carried out in the following order Remove the modulator plastic cap A using needle nose pliers Maximum pressure Turn the unit ON to its highest input rating Screw in the nut B to increase the outlet pressure and...

Страница 15: ...g h 902 154 Embers i 902 153 Rockwool j 902 179 P Vermiculite k 946 669 Platinum Embers supplied with packaged manual Note Install Optional Brick Panels prior to installing logs 1 Carefully remove the logs from the box and unwrap them The logs are fragile handle with care do not force into position 2 Sprinkle the vermiculite around the firebox base Take some of the embers approx 1 3 of the bag and...

Страница 16: ...enter Log E 02 47 over Log B 02 45 and across the cutout on Log A 02 43 Cutout Pin Cutout Notch 8 Position notch in Front Right Log F 02 48 on Log E 02 47 and push the bottom right edge against the bracket on the burner tray and the front edge of the rear burner Notch Bracket D 02 46 E 02 47 F 02 48 C 02 56 A 02 43 B 02 45 A 02 43 B 02 45 E 0 2 4 7 Logs A 02 43 C 02 56 and B 02 45 in position C 02...

Страница 17: ...ust sit snugly against the bracket and the front edge of the rear burner Side View Page 3 of 3 11 Separate platinum embers and place on and around the embers and rockwool on the burner tray Avoid stacking platinum embers 12 7HVW UH WR HQVXUH SURSHU OLJKW RII PDNH VXUH ÀDPH ÀRZV VPRRWKO IURP RQH HQG RI EXUQHU WR WKH RWKHU I WKHUH LV DQ ÀDPH KHVLWDWLRQ FKHFN WKDW DUHD IRU DQ blockage of the burner p...

Страница 18: ...wards the unit diagram 1 Be careful that the glass gasket does not roll up there must be a gap between the gasket and the door lip to ensure that the door sits securely on the unit See Diagram 2 Use the hook to pull the spring out until you can put the hook into the slot on the bottom door bracket Repeat for 2nd spring See diagram 3 To remove the flush door reverse the above steps To remove the fl...

Страница 19: ... screws 4 Install the Safety screen by hooking the top flange over the top of the glass door 5 Install the bottom door 6 Flip bottom louver up to close Completed Faceplate Safety Screen Installation 7 Insert the lip into the unit 5 Install the bottom door INSTALLATION FACEPLATE AND SAFETY SCREEN INSTALLATION 1 02 04 13 918 825c IG34 FACEPLATE OPTIONAL PLINTH TRIM ASSEMBLY DVi34L Faceplate Assembly...

Страница 20: ...SPACER INSTALLATION 1 02 04 13 918 825c IG34 FACEPLATE OPTIONAL PLINTH TRIM ASSEMBLY 1 Place the spacer on a soft cloth on the floor Slide the Right and left spacer into the top spacer secure with 2 screws on each side see image 1 below 2 Place the faceplate on a soft cloth on the floor Attach the spacer to the back of the faceplate with 2 screws on each side 3 Spacer flange must be placed inside ...

Страница 21: ...e unit to burn for 15 min to stabilize 3 Check for proper draft CAUTION Any alteration to the product that causes sooting or carboning that results in damage to the exterior facia is not the responsibility of the manufacturer WIRING Caution Ensure that the wires do not touch any hot surfaces and are away from sharp edges 909 40 STANDARD WIRING This unit is polarity sensitive and will not operate i...

Страница 22: ...his condensation is normal and will disappear in a few minutes as the glass heats up DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS STILL HOT DO NOT BURN THE APPLIANCE WITH OUT THE GLASS FRONT IN PLACE FAN OPERATION Pressing and releasing the plus FAN button will change the fan speed as follows ON HIGH Pressingandreleasingtheminus FANbutton will be the reverse of the above This appliance has 2 spee...

Страница 23: ... re occur Again this is normal for steel fireboxes Gas Control Valve As the gas control valve turns ON and OFF a dullclickingsoundmaybeaudible thisisnormal operation of a gas regulator or valve Unit Body Firebox Different types and thicknesses of steel will expand and contract at different rates resulting in some cracking and ticking sounds will be heard throughout the cycling process Appliances i...

Страница 24: ...e the flames are steady not lifting or floating If there is a problem call an authorized service person 4 The appliance and flueing system must be inspected before use and at least annu ally by an authorized field service person to ensure that the flow of combustion and ventilation air is not obstructed During the annual service call the burners should be removed from the burner tray and cleaned R...

Страница 25: ...ame and screen 6 Remove the ECS harness from the back clip 7 Pull out the ECS box NOTE The ECS box is held in place with velcro 8 Remove the 2 screws that secure the fan in place 9 Carefully slide the fan to the front rotate it 45 degrees and slide it out simultaneously with the ECS box 10 Disconnect all the connectors from the fan and resistor 11 Remove the fan ground cable 12 Reverse the above s...

Страница 26: ...ove the glass door logs and black or stainless inner liner if installed 5 Remove the rear log tray burner and grate 6 Disconnect gas line from the valve 7 Remove the firebox base plate by removing the 10 screws which hold it in place 8 Remove all the wire connectors from the valve and spark ignitor 9 Remove the valve tray assembly 10 To replace the valve tray assembly simply reverse the above step...

Страница 27: ...emove the two back brackets and screws set aside first then remove the back panel by lifting it up slightly tilt it forward then lift it out 6 Remove the two side brackets and screws set aside then remove the side panels by tilting the top in and lifting them out 7 To install do steps 6 to 1 in that order NOTE When re installing the back panel ensure the bottop lip is tucked behind the rear log tr...

Страница 28: ... N A N A N A N A N A 910 089 Flame Cable N A N A N A N A N A N A N A N A 910 088 Spark Cable N A N A N A N A N A N A N A N A 910 084 Control Box N A N A N A 911 101 Control Box N A N A N A N A N A check N A 910 527 Manual Control Switch N A N A N A N A N A N A N A 910 080 Valve 910 521 Control Box Cable 1 910 522 Control Box Cable 2 910 523 Control Box Cable 3 910 525 Control Box Cable 4 N A 2 1 1...

Страница 29: ...320 518 Flue Adaptor Assembly 6 420 048 Flue Adaptor Gasket 7 336 059 Log Tray Rear 8 336 535 Burner Assembly NG LP 9 337 013 Faceplate Mounting Bracket Left 10 337 014 Faceplate Mounting Bracket Right 11 911 121 Module SIT 230V DV 0 579 204 12 911 101 Control Box ECS III 13 402 526 Grate Diffuser Assembly 14 425 017 Side Panel LH RH Each 15 336 061 Rear Panel Back 16 336 519 P Fan Assembly Comple...

Страница 30: ...ay N S 910 522 Wire Harness ECS IP FG37 FG39 N S 910 514 Wire Jumper SIT Ignition Module N S 910 912 Wire Harness Module To Valve N S 911 113 Switch On Off W CAT 5 Cable 915 mm Long 105C N S 910 896 Wire High Temp To Power Cord N S 910 780 Wire SIT Valve Wire N S 402 935 Log Set N S 402 572 Ember Set N S 946 669 Ember Platinum Bright PBE 1 gram N S 910 692 Wire Ground 24 inch Green Fan N S 910 504...

Страница 31: ...TION IG34 TIONAL PLINTH TRIM ASSEMBLY 5 Install the bottom door 6 Flip bottom louver up to close 1 Faceplate 2 Safety Screen 3 Lip 4 Mesh Bottom Screen 5 948 042 Hinge and Hnge Support 6 Bottom Door 1 2 4 5 6 3 Not available as a replacement part OTHER OPTIONAL ACCESSORIES 337 968 Conversion Kit LP ULPG 337 918 Spacer ...

Страница 32: ... Ignition Control Boards Wiring Switches Fans Fan Control Module Battery Pack Remote Control Systems 1 Enamel Panels 1 Venting Venting Components 1 All Stainless steel surrounds 1 All Firebox Media Crystals Fire beads Volcanic Ceramic Spa Stones 1 All hardware 1 Mesh Glass Safety Barriers 1 Accent Light Bulbs 1 Glass Crazing 1 After the original warranty coverage for any of the parts above have ex...

Страница 33: ...actice of FPI to charge for larger higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated for manufacturer defect If a consumer has a unit installed outside an accredited distributor dealer or pre approved service agent s service area or the closest approved service agent is situated more than thirty 30 kilometres from the installation F...

Страница 34: ...expansion and contraction of the steel is normal and is not covered under the terms of this warranty Freight damages for products or parts are not covered under the terms of the warranty Porcelain Enamel Absolute perfection is neither guaranteed nor commercially possible Any chips must be reported and inspected by the authorised selling dealer within three 3 days of installation Any damage of this...

Страница 35: ...option of the supplier one or more of the following i replacement of the goods or the supply of equivalent goods ii the repair of the goods iii the payment of the cost of replacing the goods or of acquiring equivalent goods or iv equivalent goods or v the payment of the cost of having the goods repaired b To the extent that services supplied by the supplier are services other than services of a ki...

Страница 36: ...replace Products Australia Pty Ltd 1 3 Conquest Way Hallam VIC Australia 3803 Phone 61 3 9799 7277 Fax 61 3 9799 7822 To obtain warranty service in Western Australia and or New Zealand please contact one of our authorised distributors in those areas Western Australia Air Group Australia 28 30 Division St Welshpool WA Australia 6106 Phone 08 9350 2200 Fax 08 9353 4225 New Zealand Aber Holdings Ltd ...

Страница 37: ...for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For purchases made in CAN...

Страница 38: ...38 Regency DVi34L Gas Inbuilt Fireplace ...

Страница 39: ...39 Regency DVi34L Gas Inbuilt Fireplace ...

Страница 40: ...______ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial No ___________________________________________________________ IMPORTANT A certificate of compliance or equivalent by an authorised installer must be obtained on commissioning of appliance to obtain warranty Printed in Canada Copyright 2020 FPI Fir...

Отзывы: