18
|
Regency I2500M
|
18
installation
3)
Tilt the left baffle up on top of the side chan-
nel and it will leave enough room to position
the right baffle in the same manner as Step 1)
above. Then reposition the left baffle flat on the
air tubes.
Side View
Front View
Front View
4) Important: push both baffles so they are
tight against the side walls.
The unit arrives with the 2 baffle plates on the
floor of the firebox.
1)
If all 4 air tubes are installed continue on to Step
2), if not, follow the instructions below. Install
the air tube into the holes in the side channels.
The notch goes on the right hand side with the
air holes facing toward the door. Slide the tube
into the left hand side, as far as possible and
then bring it back into the hole on the right hand
side. Use a pair of vise grips or pliers and tap
it into place with a hammer. A tighter fit will
ensure the tube will not move when the unit is
burning. Though there are four air tubes in the
medium units.
2)
Slide the left baffle over the air tubes from the
front and then push it to the back.
FLUE BAFFLE &
SECONDARY AIR TUBE
INSTALLATION
The flue baffle system located in the upper area
of the firebox is removable to make cleaning your
chimney system easier. The baffles must be
installed prior to your first fire.
Smoke spillage
and draft problems may occur if the baffles are
improperly positioned.
Check the position of the
baffles on a regular basis as they can be dislodged
if too much fuel is forced into the firebox.
GLASS REPLACEMENT
Your Regency stove is supplied with 5 mm Neoceram
ceramic glass that will withstand the highest heat that
your unit will produce. In the event that you break
your glass by impact, purchase your replacement
from an authorized Regency dealer only.
Remove the door from the stove and remove the
screws securing the glass retainer. Position the glass
in the door, make sure that the glass gasketing will
properly seal your unit, and replace the retainer,
it should rest on the gasket not the glass. Tighten
securely, but do not wrench down on the glass as
this may cause the glass to break.
Shown with classic door
FLOOR PROTECTION
Please check to ensure that your floor protection
and hearth will meet the standards for clearance to
combustibles. Your hearth extension must be made
from a non-combustible material.