background image

14

     | 

F1150 Regency Freestanding Woodstove

installation

Method A

: 12" (304.8 mm) Clearance to Combustible Wall Member:

Using a minimum thickness 3.5" (89 mm) brick and a 5/8" (15.9 mm) 
minimum  wall  thickness  clay  liner,  construct  a  wall  pass-through.  
The clay liner must conform to ASTM C315 (Standard Specification 
for Clay Fire Linings) or its equivalent. Keep a minimum of 12" (304.8 
mm) of brick masonry between the clay liner and wall combustibles.  
The clay liner shall run from the brick masonry outer surface to the 
inner surface of the chimney flue liner but not past the inner surface.  
Firmly grout or cement the clay liner in place to the chimney flue liner.  

 

Method B

: 9" (228.6 mm) Clearance to Combustible Wall Member:

Using a 6" (152.4 mm) inside diameter, listed, factory-built Solid-Pak 
chimney section with insulation of 1" (25.4 mm) or more, build a wall 
pass-through with a minimum 9" (228.6 mm) air space between the 
outer wall of the chimney length and wall combustibles. Use sheet metal 
supports fastened securely to wall surfaces on all sides, to maintain the 
9" (228.6 mm) air space. When fastening supports to chimney length, 
do not penetrate the chimney liner (the inside wall of the Solid-Pak 
chimney).  The inner end of the Solid-Pak chimney section shall be 
flush with the inside of the masonry chimney flue, and sealed with a 
non-water soluble refractory cement.  Use this cement to also seal to 
the brick masonry penetration.

Minimum

12 in. (304.8mm)

to combustibles

Masonry chimney

Chimney

Flue

Minimum chimney clearance to brick
and combustibles 2 in. (50.8mm)

Minimum clearance
12 in. (304.8mm)
of brick

Chimney
connector

Fire clay
liner

Method C

: 6" (152.4 mm) Clearance to Combustible Wall Member:

Starting with a minimum 24 gage (.024" [.61 mm]) 6" (152.4 mm) metal 
chimney connector, and a minimum 24 gage ventilated wall thimble 
which  has  two  air  channels  of  1"  (25.4  mm)  each,  construct  a  wall 
pass-through. There  shall  be  a  minimum  6"  (152.4  mm)  separation 
area containing fiberglass insulation, from the outer surface of the wall 
thimble to wall combustibles.  Support the wall thimble, and cover its 
opening with a 24-gage minimum sheet metal support. Maintain the 
6" (152.4 mm) space.  There should also be a support sized to fit and 
hold the metal chimney connector. See that the supports are fastened 
securely to wall surfaces on all sides.  Make sure fasteners used to 
secure the metal chimney connector do not penetrate chimney flue liner.  

Method D

: 2" (50.8 mm) Clearance to Combustible Wall Member:

Start with a solid-pak listed factory built chimney section at least 12" 
(304 mm) long, with insulation of 1" (25.4 mm) or more, and an inside 
diameter of 6" (2 inches [51 mm] larger than the 6" [152.4 mm] chimney 
connector). Use this as a pass-through for a minimum 24-gage single 
wall steel chimney connector. Keep solid-pak section concentric with 
and spaced 1" (25.4 mm) off the chimney connector by way of sheet 
metal support plates at both ends of chimney section.  Cover opening 
with and support chimney section on both sides with 24 gage minimum 
sheet metal supports. See that the supports are fastened securely to 
wall surfaces on all sides. Make sure fasteners used to secure 

the 

metal chimney connector do not penetrate 

chimney flue liner.

Combustible Wall Chimney Connector Pass-throughs

Содержание Cascades F1150

Страница 1: ...50 Cascades Series Freestanding Woodstove 12 10 19 Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions for future...

Страница 2: ...te this wood heater in a manner inconsistent with operating instructions in this manual CAUTION BURNUNTREATEDWOODONLY OTHERMATERIALSSUCHASWOODPRESERVATIVES METALFOILS COAL PLASTIC GARBAGE SULPHUR OR O...

Страница 3: ...ng Bottom Heat Shield Legs 17 Recommended Heights For Woodstove Flue 18 Optional Outside Air Kit 19 Brick Installation 20 Removing Wooden Handle 21 Glass Installation 21 Wood Door Handle Assembly 22 F...

Страница 4: ...E ALSO SUITABLE FOR MOBILE HOME INSTALLATION APPAREIL DE CHAUFFAGE AMBIANT HOMOLOGU COMBUSTIBLE SOLIDE CONVENANT AUSSI POUR INSTALLATION DANS UNE MAISON MOBILE FLOOR PROTECTION PROTECTION DE PLANCHER...

Страница 5: ...4 831mm 24 610mm 30 3 8 772mm 12 7 8 326mm 17 3 8 441mm 20 508mm 6 1 2 165mm 7 13 16 199mm 29 11 16 753mm 32 813mm Unit with pedestal Unit with legs Outside Air Dimensions Rear Front 4 9 16 115mm Rea...

Страница 6: ...le wall OK double wall chimney the chimney connector must be at least 24 gauge steel Do not use galvanized pipe For Mobile Home installation refertotheMobileHomeinstallationinstructions within this ma...

Страница 7: ...rear heat deflector is installed on top of the rear heat shield as shown in Diagram 4 Side Shield Adjustment The left and right side shields are lowered for ship ping and handling It allows for a hand...

Страница 8: ...and tighten the bolts 4 Level the stove by adjusting the levelling bolts in the bottom of each leg 5 Reinstall cover plate if not using ash drawer option 6 Install logo plate onto heat shield by plac...

Страница 9: ...is installed as a close clearance residential unit a listed double wall connector is required from the stove collar to the ceiling level F1150 withAirmateor RearDeflector A B C D E F 11 279mm 7 178mm...

Страница 10: ...USA Beneath the heater and extending to at least 16 405mm beyond the fuel loading side and ash removal opening and at least 8 203mm on the sides and back and under the chimney connector extending 2 51...

Страница 11: ...nstallation A combustible floor must be protected by non combustible material like tile concrete board or certified to UL 1618 or as defined by local codes extending beneath the heater and a minimum o...

Страница 12: ...to initially try with the minimum required height and then if problems do arise add additional height at a later date 4 Slide the roof flashing over your chimney and seal the flashing to the roof wit...

Страница 13: ...kage Have the chimney cleaned before the stove is installed and operated When connect ing the stove through a combustible wall to a masonrychimney specialmethodsareneeded Ensure that an effective vapo...

Страница 14: ...ombustibles 2 in 50 8mm Minimum clearance 12 in 304 8mm of brick Chimney connector Fire clay liner Method C 6 152 4 mm Clearance to Combustible Wall Member Starting with a minimum 24 gage 024 61 mm 6...

Страница 15: ...of exit for a height up to 7ft 2130mm 6 Thechimneyshallbeattacheddirectlytotheroom heater and shall extend at least 3 ft 914mm above the part of the roof through which it passes The top of the chimney...

Страница 16: ...re flex to the Mobile Home box 7 Secure pedestal base and Mobile Home Box to firebox as shown in diagram 3 using the screws that were previously removed loosened in step 1 See pedestal instructions Th...

Страница 17: ...nking plate to the front of the pedestal with 4 screws Use picture from step 8 16 Install the mandatory outside air kit See Mobile Home Instal lation section in this manual Place unit into its final p...

Страница 18: ...0 18 0 22 5 4000 5000 14 0 15 0 16 0 17 5 21 0 18 5 23 0 5000 6000 14 5 15 5 17 0 18 0 21 5 19 0 24 0 6000 7000 15 0 16 0 17 5 18 5 22 5 20 0 25 0 7000 8000 15 5 16 5 18 0 19 0 23 0 20 5 25 5 8000 90...

Страница 19: ...fresh air into the pedestal area by using a minimum 4 duct pipe with a mesh grill at the outside termination Outside Air Through Pedestal Rear Remove the blanking plate from the rear of the pedestal a...

Страница 20: ...cks were removed at install per the diagram below and place in their correct positions Do not use a grate NOTE The AD brick covers the Ash Dump hole that is used if an Ash Drawer Kit is not installed...

Страница 21: ...ws securing the glass retainer Position the glass in the door make sure that the glass gasketing will properly seal your unit and replace the retainer it should rest on the gasket not the glass Tighte...

Страница 22: ...r is not creating a tight seal a washer can be removed Recheck door to ensure there is still a tight seal Repeat steps if door seal is still not tight until a tight seal has been achieved The handle s...

Страница 23: ...with the stove body Remove the fan bend the bracket closer to the stove and re install the fan The fan is to be operated in the LOW position when burning in the LOW MED LOW heat output setting and on...

Страница 24: ...osen off both bolts and slide deflector downward push deflector to the back wall of the unit and manoeuver out Install new deflector and hand tighten bolts Ensure positive location of the deflector pr...

Страница 25: ...he flue baffle It may be easier to complete this procedure if the smoke deflector is removed if already installed see previous page for removal procedure 1 Open the unit door 2 Remove front air tube i...

Страница 26: ...t dries Two dry pieces banged together sound hollow wet pieces sound solid and dull Dry wood weighs much less than wet wood Split a piece of wood If the exposed surface feels damp the wood is too wet...

Страница 27: ...his is to be expected as thehightemperaturepaintbecomesseasoned Windows and or doors should be left open to provide adequate ventilation while this tem porary condition exists Burning the stove at a v...

Страница 28: ...oid your warranty 6 Do not permit creosote or soot build up in the chimney system Check and clean chimney at regular intervals Failure to do so can result in a serious chimney fire 7 YourRegencystovec...

Страница 29: ...CARBON MONOXIDE AND ARE VERY DANGEROUS 14 WARNING Do not operate without either the Ash Plug properly seated or the Ash Dump Plates screwed in place excessive temperatures will result 15 CAUTION Do n...

Страница 30: ...sote deposits may build up rapidly Moving parts of your stove require no lubrication 4 A small hot fire is preferable to a large smoul dering one that can deposit creosote within the system 5 The chim...

Страница 31: ...the remaining 2 tubes Secondary Air Tubes 5 To reinstall or replace first slide left side of tube into hole on left side air channel Align tab on right side air channel with notch on right hand end of...

Страница 32: ...ondary air tubes page 31 vermiculite baffles page 25 2 Loosen the two 7 16 bolts nuts to remove replace vertical baffle 3 Repeat steps to install new vertical deflector NOTE ENSURE BAFFLE IS PUSHED UP...

Страница 33: ...r on a cold stove Close the door Try to remove the paper by pulling The paper should not pull out easily if it does try adjusting the door latch if that doesn t solve the problem replace the door gask...

Страница 34: ...lass Retainer 15 021 973 Door Handle Assembly Complete 16 948 079BN Hinge Cap Brush Nickel Each 17 948 146 Long Black Handle 18 850 241 Black Door Complete 18 850 243 Black with Nickel Accent Door Com...

Страница 35: ...F1150 Regency Freestanding Woodstove 35 parts list 4 2 23 3 8 7 6 24 14 11 13 16 15 12 17 18 22 19 21 25 20 26 Main Assembly...

Страница 36: ...at Shield 43 942 110 Ashplug 44 820 249 Ashplug Tool 45 075 079 Blanking Plate N S 905 008 5 16 x 6 Long Hex Head Bolt Each N S 820 468F Metal Washer N S 820 456 Metal Spacer Support Bracket Each part...

Страница 37: ...anding Woodstove 37 parts list 6 3 3 4 1 2 7 5 2 1 4 3 6 7 AD Fire bricks Size 1 4 1 4 x 7 2 4 1 2 x 7 3 9 x 4 1 2 4 9 x 2 5 3 1 2 x 4 1 2 AD 6 4 1 4 x 8 7 3 1 2 x 2 1 4 AD Ashdump brick 075 960 F1150...

Страница 38: ...38 F1150 Regency Freestanding Woodstove notes...

Страница 39: ...azing 1 Catalyst Combustor 10 Years Prorated Venting Chimney 1 Screens 1 See specific warranty details in regards to the catalyst combustor in unit manual Conditions Warranty protects against defect i...

Страница 40: ...ncorrect chimney components including but not limited to cap size or type operator error abuse misuse use of improper fuels such as unseasoned cordwood mill ends construction lumber or debris off cuts...

Страница 41: ...ental or consequential damages so the above limitations or exclusions may not apply to you Customers located outside the U S should consult their local provincial or national legal codes for additiona...

Страница 42: ...order for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Detai...

Страница 43: ...F1150 Regency Freestanding Woodstove 43 notes...

Страница 44: ...44 F1150 Regency Freestanding Woodstove notes...

Страница 45: ...F1150 Regency Freestanding Woodstove 45 notes...

Страница 46: ...46 F1150 Regency Freestanding Woodstove notes...

Страница 47: ...F1150 Regency Freestanding Woodstove 47...

Страница 48: ...ealer Name Address _______________________________________________ ___________________________________________________________________ Installer _______________________________________________________...

Отзывы: