38
|
Regency Bellavista
®
B41XTCE -11 Gas Fireplace
installation
7. Ensure that the pipe clearances to combus-
tible materials are maintained (Diagram 55).
Install the termination cap.
Note: If installing termination on a
vinyl siding covered wall, a vinyl
siding standoff or furring strips
must be used to ensure that the
termination is not recessed into
the siding.
The four wood screws provided should be re-
placed with appropriate fasteners for stucco,
brick, concrete, or other types of sidings.
8. Before connecting the horizontal run of vent
pipe to the vent termination, slide the Wall
Thimble over the vent pipe. The wall thimble
is required for all horizontal terminations.
9. Slide the appliance and vent assembly
towards the wall carefully inserting the vent
pipe into the vent cap assembly. It is important
that the vent pipe extends into the vent cap
sufficient distance so as to result in a minimum
pipe overlap of 1-1/4 inches (32mm). Secure
the connection between the vent pipe and
the vent cap.
10. Install wall thimble in the center of the framed
hole and attach with wood screws (Diagram
56).
Install the vent system according to the
manufacturer's instructions included with the
components.
1. Set the unit in its desired location. Check
to determine if wall studs or roof rafters are
in the way when the venting system is at-
tached. If this is the case, you may want to
adjust the location of the unit. Rough in the
gas preferably on the right side of the unit
and the electrical (junction block is on the
left side) on the left.
2. Direct Vent pipe and fittings are designed with
special twist-lock connections to connect the
venting system to the appliance flue outlet.
A twist-lock appliance adaptor is required.
3. In conjunction with the Approved Vent system,
install the adaptor after the unit is set in its
desired location. Slip the adapter over the
existing inner and outer flue collar. Fasten to
the outer collar only with the 3 supplied screws
(drilling pilot holes will make this easier).
4. Level the fireplace and fasten it to the framing
using nails or screws through the top and
side nailing strips.
Note: For best results and optimum
performance with each approved
venting system, it is highly
recommended to apply “Mill-
Pac” sealant (supplied) to every
inner pipe connection. Failure to
do so may result in drafting or
performance issues not covered
under warranty.
Horizontal runs of vent must be supported
every 3 feet (0.9meter). Wall straps are avail-
able for this purpose.
6. Mark the wall for a square hole.-see chart
to left for size. The center of the square hole
should line up with the center-line of the
horizontal pipe. Cut and frame the square
hole in the exterior wall where the vent will
be terminated. See diagram 54 for center
line requirements.
If the wall being penetrated is constructed of
non-combustible material, i.e. masonry block
or concrete, an 8" (203mm) diameter hole
is acceptable.
Notes:
a)
The horizontal run of vent must be level, or
have a 1/4 inch rise for every 1 foot of run
towards the termination. Never allow the
vent to run downward. This could cause
high temperatures and may present the
possibility of a fire.
b) The location of the horizontal vent
termination on an exterior wall must meet
all local and national building codes, and
must not be blocked or obstructed. See
"Exterior Vent Termination Locations"
section for more details.
5. Assemble the desired combination of pipe
and elbows to the appliance adaptor and
twist-lock for a solid connection.
CL
CL
47-1/2
Rea
r
V
ent
”
(1
2
07mm)
Min.
height
(5
28-1/2”
(724mm)
”
x
8
”)
center
of hole
Horizontal Top*
3" (76mm)*
Horizontal Side
2 " (51mm)
Horizontal Bottom
2" (51mm)
Vertical Vent
2" (51mm)
Minimum Vent Clearances
to Combustibles
Unit Installation with
Horizontal Termination
5" x 8" Venting
(Rigid Vent Systems)
Below are the recommended framing dimen-
sions (inside measurements) for the 5" x 8"
rigid vent terminations - for use with a firestop
or wall thimble.
IMPORTANT
Must use Rear Venting Deflector packaged with
unit in rear vent horizontal termination
applications.
Diagram 53
Diagram 54
Diagram 55
Diagram 56
* Clearances noted below must be maintained;
except when passing through a wall, ceiling or
at the termination where the use of a firestop
or wall thimble reduces clearance to 1-1/2"
(38mm).
Содержание Bellavista B41XTCE
Страница 63: ...Regency Bellavista B41XTCE 11 Gas Fireplace 63 notes ...
Страница 68: ...68 Regency Bellavista B41XTCE 11 Gas Fireplace warranty ...
Страница 69: ...Regency Bellavista B41XTCE 11 Gas Fireplace 69 notes ...
Страница 70: ...70 Regency Bellavista B41XTCE 11 Gas Fireplace notes ...
Страница 71: ...Regency Bellavista B41XTCE 11 Gas Fireplace 71 ...