Regency Bellavista
®
B41XTCE -11 Gas Fireplace
installation
V
enting Arrangements for Vertical Termination
s
The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations, using two 90
o
elbows, with
Rigid Pipe
Venting Systems for Propane and Natural Gas. Two 45
o
elbows equal to one 90
o
elbow. Maximum of four 45
o
elbows allowed.
• Vent must be supported at offsets.
• Firestops are required at each floor level and whenever passing through a wall.
• Maintain clearances to combustibles as listed in the "Clearances" section.
• Refer to the "Vent Restrictor Position" section for details on how to change the vent restrictor from the factory setting to 3-1/2"
opening, 2-1/2"opening and to 1-1/2" opening.
Note: Must use optional flue adapter when using Rigid Pipe (Part # 770-994).
Minimum
8’
(2.4m)
Min. 47-1/2
”
(1.2m)
0
2
4
6
40
8
10
12
14
16
18
20
22
24
26
28
30
V
ertical Height (Feet)
32
34
36
38
6
8
Horizontal (Feet)
2
0
4
10
12
Restrictor 1-1/2” Open
Maximum 10’ Centerline to Centerline
Restrictor 2-1/2” Open
Maximum 8’ Centerline to Centerline
Restrictor 3-1/2” Open
Set 2
Set 3
Set 1
Diagram 51
Содержание Bellavista B41XTCE
Страница 63: ...Regency Bellavista B41XTCE 11 Gas Fireplace 63 notes ...
Страница 68: ...68 Regency Bellavista B41XTCE 11 Gas Fireplace warranty ...
Страница 69: ...Regency Bellavista B41XTCE 11 Gas Fireplace 69 notes ...
Страница 70: ...70 Regency Bellavista B41XTCE 11 Gas Fireplace notes ...
Страница 71: ...Regency Bellavista B41XTCE 11 Gas Fireplace 71 ...