B41XTCE Gas Fireplace

Model

B41XTCE-NG10

B41XTCE-LP10

Fuel Type

Natural Gas

Propane

Minimum Supply Pressure

5” W.C./C.E. (1.25 kPa)

11” W.C./C.E. (2.74 kPa)

Manifold Pressure - High

3.5” W.C./C.E. (0.87 kPa)

10” W.C./C.E. (2.49 kPa)

Manifold Pressure - Low

1.6” W.C./C.E. (0.40 kPa) 6.4” W.C./C.E. (1.60 kPa)

Orifice Size -

Altitude 0-4500 ft.

#30 DMS 

#49 DMS 

Minimum Input  

Altitude 0-4500 ft. (0-1372m)

30,000 BTU/h   

(8.79 kW)

29,500 BTU/h 

(8.65 kW) 

Maximum Input 

Altitude 0-4500 ft. (0-1372m)

42,500 BTU/h 

(12.45 kW)

37,500 BTU/h 

(10.99 kW)

Q

P

U V

T

Opening for gas

connection

11" (279mm)

dia. Hole through

wall Vent.

Non-Combustible

Header

(steel stud) on edge

Drywall

(or other

facing)

W

Non-Combustible Facing

S

S

R

Non-combustible

Header

(steel stud

on edge)

M

N

L

O

** Important:  Framing height requires consideration of the hearth depth.  

Dimension N = N + the thickness of the installed hearth.

Approved Venting Systems

Flex Vent Systems:

FPI AstroCap™ Flex Vent

Rigid Pipe Vent Systems:

Simpson Direct Vent Pro®

Selkirk Direct-Temp™

Metal-Fab® Sure Seal

ICC Excel Direct Vent

Framing 

Dimensions

Description

B41XTCE

M

Framing Width

47-1/4"(1200mm)

N

Framing Height

49-1/2" (1257mm)

O (Rear Vent)

Framing Depth - Rear Vent

26-1/2" (673mm) 

O  (Top Vent)

Framing Depth - Top Vent

25-7/8" (657mm) 

P  

Corner Facing Wall Width

65-1/4" (1657mm)

Q  

Corner Facing Wall Width

91-11/16" (2329mm)

R (Rear Vent)

Framed Chase Ceiling - Rear

49-1/2" (1257mm)

R (Top Vent)

Framed Chase Ceiling - Top

54-1/2" (1384mm)

S  (Rear Vent)

Vent Centerline Height - Rear

28-1/2" (724mm)

S  (Top Vent) 

Vent Centerline Height - Top

47-1/2" (1207mm) Rigid / Flex

T

Gas Connection Height

1-1/2" (38mm)

U

Gas Connection Inset

5" (127mm)

V

Gas Connection Width

3-1/4" (82mm)

W

Non-Combustible Top Height

13-1/2" (343mm)

Содержание Bellavista B41XTCE

Страница 1: ...aming height requires consideration of the hearth depth Dimension N N the thickness of the installed hearth Approved Venting Systems Flex Vent Systems FPI AstroCap Flex Vent Rigid Pipe Vent Systems Simpson Direct Vent Pro Selkirk Direct Temp Metal Fab Sure Seal ICC Excel Direct Vent Framing Dimensions Description B41XTCE M Framing Width 47 1 4 1200mm N Framing Height 49 1 2 1257mm O Rear Vent Fram...

Страница 2: ... required clearances air space to combustible materials It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions Clearance Dimension Measured From A Mantel Height min 17 9 16 446mm Top of Fireplace Opening B Sidewall 9 229mm Side of Fireplace Opening C Ceiling 36 5 8 930mm Top of Fireplace Opening D Mantel Depth max 12 304mm 25 13...

Страница 3: ...on combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non combustible board Combustible Mantel Clearances 2 0 12 6 4 8 10 0 Top of Fireplace Opening 12 1 7 A B C Non combustible Header steel stud on edge 14 To Floor 12 24 Inches D 6 Non combustible Standoff Mantel Clearances B41XTCE A B C D From Top of Fireplace Opening 32 11 16 830mm 25 13 1...

Страница 4: ...e finishing material tile slate etc the material can be installed directly onto the metal surface clean front of the unit in the area shown below CLEAN FINISH 6 If applying a non combustible facing it may be installed over the metal surface clean front of the unit in the area shown below Combustible and Non combustible Facing and Finishing Materials around unit 38 7 16 976mm 29 737mm Combustible M...

Страница 5: ...anel NOTE Non combustible finishing materials may be of any thickness desired Minimum Clearances for Finishing Materials Trim materials Note All non combustible facingmaterialshouldbuttupcleanly to the flanges around the firebox opening Rough edges may be visible from an angle To maintain a clean finished edge facing material edges may be finished with a J style trim or metal cornerbead both mater...

Страница 6: ...Height Feet Rigid or Flex 47 1 2 1 2m Horizontal Feet Max 36 0 9m 2 0 6 4 8 2 0 6 4 8 Vertical Height Feet 28 1 2 0 7m Horizontal Feet Max 36 0 9m Vent Restrictor Set 1 Factory Setting No Restrictor Required VENTING ARRANGEMENTS FOR HORIZONTAL TERMINATIONS FLEX VENT OR RIGID PIPE 5 X 8 REAR VENTING DEFLECTOR INSTALLATION FOR REAR VENTED HORIZONTAL TERMINATIONS Rear Venting Deflector The Rear Vent ...

Страница 7: ...iagram shows all allowable combinations of straight vertical and offset to vertical terminations using two 90o elbows with Rigid Pipe Venting Systems for Propane and Natural Gas Two 45o elbows equal to one 90o elbow Maximum of four 45o elbows allowed Minimum 8 2 4m Min 47 1 2 1 2m 0 2 4 6 40 8 10 12 14 16 18 20 22 24 26 28 30 Vertical Height Feet 32 34 36 38 6 8 Horizontal Feet 2 0 4 10 12 Restric...