Regency B36XTCE Gas Fireplace
13
INSTALLATION
FRAMING
Q
P
U V
T
Opening for gas
connection
11" (279mm)
dia. Hole through
wall Vent.
Non-Combustible
Header
(steel stud) on edge
Drywall
(or other
facing)
W
Non-Combustible Facing
S
S
R
Non-combustible
Header
(steel stud
on edge)
M
N
L
O
Framing Dimensions
Description
B36XTCE
L
Framing rise from fl oor
0" (when not using a surround)
1" min (when using Mantel)
M
Framing Width
41-1/4"(1048mm)
N
Framing Height
42" (1067mm)
O (Rear Vent)
Framing Depth - Rear Vent
23-7/8" (606mm)
O (Top Vent)
Framing Depth - Top Vent
23-7/8" (606mm)
P (Top Vent)
Corner Facing Wall Width
53-1/4" (1353mm)
P (Rear Vent)
Corner Facing Wall Width
57-7/8" (1470mm) AstroCapXL
66-1/8" (1670mm) - other approved caps
Q (Top Vent)
Corner Facing Wall Width
75-1/4" (1911mm)
Q (Rear Vent)
Corner Facing Wall Width
81-1/2" (2070mm) AstroCapXL
93-1/2" (2375mm) - other approved caps
R (Rear Vent)
Framed Chase Ceiling - Rear
41-1/2" (1054mm)
R (Top Vent)
Framed Chase Ceiling - Top
50-1/2" (1283mm)
S (Rear Vent)
Vent Centerline Height - Rear
26-1/2" (673mm)
S (Top Vent) (5" x 8")
Vent Centerline Height - Top
42-1/8" (1070mm) Flex
44-1/4" (1123mm) Rigid
S (Top Vent) (4" x 6-5/8")
Vent Centerline Height - Top
-
49" (1245mm) Rigid
T
Gas Connection Height
1-1/2" (38mm)
U
Gas Connection Inset
7-3/8" (187mm)
V
Gas Connection Width
3-1/4" (82mm)
W
Non-combustible Height
3-1/2"" (89mm)
** Important: Framing height requires consideration of the hearth depth. Dimension N = N + the thickness of the installed hearth.
Содержание Bellavista B36XTCE
Страница 70: ...70 Regency B36XTCE Gas Fireplace NOTES ...