Manual
– TopCon TC.LAE
Installation and commissioning
32 / 56
2016-06-08
6.2.5.
Dis-/connect a quick release coupling system (Option)
In case the TC.LAE device is delivered with the quick release coupling
connection system (option)
1
2
3
Fig. 19
Non drip couplings
-3-
and nipples
-2-
.
Procedure: dis-/connect the quick release coupling system
Pulling back the retaining ring of the quick release coupling
-1-
until the following procedure steps are finished.
For device removal
Pull out the nipple
-2-
from the female coupling
-3-.
For device installation
Push in the nipple
-2-
in the female coupling
-3-
.
Release the retaining ring
-1-
of the quick release coupling.
The retaining ring returns to its original position.