Manual - TC.P Quadro
Internal system communication
2016-08-05
135/330
V04.52
5
Fig. 70
Interlock connection scheme for TopCon power supplies via the
CAN cable and the related dummy plugs.
Interlock modules in accordance with Fig. 70
1
External EMERGENCY STOP button that can interrupt the interlock circuit
2
Dummy plug “
X101; CAN TERM; Interlock CTR 4
“
Is connected to interface X101 on the rear side so that the interlock circuit is
not interrupted. (If there is no circuit -1-)
3
Dummy plug “
X105; Interlock CTR 4”
Is connected to interface X105 on the rear side so that the interlock circuit is
not interrupted.
4
CAN cable connects interface X102 on the first device to the interface X101
on the following device.
Table 71
Connection of dummy plugs to the related interfaces in the multi-unit system.