RCL40 & RCL41
Installation manual
Regasense is a part of Regal Components |
Rev. no.
2021_1
7
Installation of connector 6140
1. Place o-ring on connector. Recommended
o-ring: 14 x 1,78 mm NBR70. Not included in
scope of delivery.
2. Cut the sensor wires to suitable length.
3. Place heat shrink tube on the wires.
4. Strip 10 mm of the wires and twist them in pla-
ce in the pins of the connector. See connection
in table below.
5. Solder the joints.
Soldering shall be done by personnel with pro-
per training.
6. Heat the heat shrink wires in place over the
solder joints.
7. Mount the connector in place
.
Make sure that the wires are free from mecha-
nical stress.
A
A
B
C
D
1
4
3
A. Solder pins
B. O-ring
C. Pin number
Electrical connection 6140
Solder pin
Sensor wire
Function
1
Red
lb
3
Black
Vb
4
-