Regal REGASENSE RCL40 Скачать руководство пользователя страница 1

Regasense is a part of Regal Components   |

Installation Manual

RCL40, RCL41 & RCL41P

Inductive cylinder sensor with

RCL41 & RCL43

Control box

Содержание REGASENSE RCL40

Страница 1: ...Regasense is a part of Regal Components Installation Manual RCL40 RCL41 RCL41P Inductive cylinder sensor with RCL41 RCL43 Control box...

Страница 2: ...itional safety measures to prevent injury or damage Warranty Regal Components AB grants warranty according to Nordiska leveransbest mmelser NL09 in applicable areas or Orgalime S2012 Warranty is not p...

Страница 3: ...se is a part of Regal Components Rev no 2021_1 3 Part design A B RCL41 RCL41P RCL40 C D E F G Sensor body A Sensor header B Flange sensor tube C Sensor tube D Sensor rod E PUR cabel output F PUR cabel...

Страница 4: ...ave spring washer 2 pcs retaining ring RCL43 controller RCL41 DIN controller Sensor and control box are sold separate Accessories Additional accessories not included in the standard scope of delivery...

Страница 5: ...all be intact Installation accessories shall be in good condition The drilling dimensions in the cylinder must be within specified tolerances Otherwise there is risk of malfunction and or vibration ca...

Страница 6: ...w with suitable sealing compound The force from the hydraulic pressure shall apply on the back side of the sensor head against the cylinder body the set screw shall not hold this force b Or use the re...

Страница 7: ...on the wires 4 Strip 10 mm of the wires and twist them in pla ce in the pins of the connector See connection in table below 5 Solder the joints Soldering shall be done by personnel with pro per traini...

Страница 8: ...e sensor wires from factory 1 Assemble the crimp contacts with sensor wire to the splice ring Connection shown in table below 2 Attach the contact carrier 3 Insert the o ring into the groove on the ho...

Страница 9: ...power supply and 0V as well as choosen output configuration before the power is switched on Find the schematic under the instructions for each controller Always use shielded cables to connect the sen...

Страница 10: ...from the sensor head Terminal 4 4 20 mA Terminal 5 0 5 V The output can be configured by adding jumper wi res to special terminals on the controller according to the table 0 10 V output It is possibl...

Страница 11: ...0 mA Terminal 5 0 5 V The output can be configured by adding jumper wi res to special terminals on the controller according to the figure 0 10 V output It is possible to achieve a 0 10V output from th...

Страница 12: ...the screw BALANCE until 50 of the output is achieved for example 12 mA on 4 20 mA output 3 Run the piston rod to the desired inner position Adjust with the screw GAIN until 0 of the output or 100 if...

Страница 13: ...or measure the resistance and check that it is in the range of 9 100 Also check that there is insulation between the sensor wires and the shield or ground of the system Control box If a system is malf...