Regal Century EVQ165 Скачать руководство пользователя страница 14

14

The user can follow the below illustrations to operate 

Schedule Set Mode

:

To enter 

Schedule Set 

Mode

 

PRESS and HOLD 

button for 3 seconds then 

release:

While in 

Schedule Set Mode

 

light will blink quickly:

To set the desired schedule, PRESS the button the number of times as the 

schedule number. For example, to set schedule 8 PRESS the button 8 times 

and then PRESS and HOLD for 3 seconds, then release:

PRESS & HOLD for 3 Seconds

3 sec

1

4

 sec

1

4

 sec

NOT RUNNING

RUNNING (any speed)
RUNNING (high speed)

PRESS & HOLD for 3 Seconds

3 sec

PRESS

= CURRENT
SCHEDULE #

NOTE: 

To confirm the newly set schedule, the motor will automatically go 

into 

Schedule Check Mode

. Refer to section 4.4 for more information on 

Schedule Check Mode

. If at any time the motor does not enter 

Schedule 

Check Mode 

after inputting the desired schedule, repeat the steps above.

Automatic exiting of  

Schedule Set Mode

:

45 Seconds

Once you have the dip switches in the proper position, the user can then 

select which of the 8 pre-programmed operating schedules they would like the 

VGreen Evo™ motor to run in by entering 

Schedule Set Mode

Содержание Century EVQ165

Страница 1: ...INSTALLATION MANUAL AND USER GUIDE VGREEN EVO VARIABLE SPEED MOTOR...

Страница 2: ...rt symbols and signal words They alert the user to potential personal injury hazards Obey all safety messages to avoid possible injury or death or damage to equipment and other property TABLE OF CONTE...

Страница 3: ...tor replacement VGreen Evo Motor Features Freeze Protection Sealed Ball Bearings TEFC Design Rotation CCWPE Single Phase 50 60 Hz Variable Speed Operation 600 3450 RPM 303 Stainless Steel Shaft Class...

Страница 4: ...according to the locally adopted version of the NEC A licensed qualified electrician should complete the wiring for this product The motor is designed to operate with 230 115 VAC single phase power an...

Страница 5: ...lined in sections 4 1 through 4 5 OPERATING MODE BUTTON OVERRIDE MODE PAUSE MODE SCHEDULE CHECK MODE SCHEDULE SET MODE B u t t o n A u t o T i m e o u t P r e s s 1 X Button Auto Aut o Tim eou t Press...

Страница 6: ...during Operating Mode While in Operating Mode during Priming light will be on continuously and motor will be running While in Operating Mode during Schedule Running RPM the light will be on continuous...

Страница 7: ...at 3450 RPM there will be no change in motor speed Follow the illustrations below to operate Override Mode To enter Override Mode PRESS button 1 time To exit Override Mode PRESS and HOLD button for 3...

Страница 8: ...the VGreen Evo motor is currently running the user can follow the below illustrations to operate Pause Mode To enter Pause Mode PRESS button 2 times While in Pause Mode light will blink slowly There...

Страница 9: ...link 1 8 times depending upon the set schedule Then the light will turn off for 3 seconds Once the light blinking sequence is complete the light will turn off and the motor will automatically return t...

Страница 10: ...ip switch positions must be set to 3 OFF 4 OFF SCHEDULE SET A SCHEDULE PRIME WHEN MOTOR STARTS FROM A STOPPED POSITION HOURS 0 2 HOURS 2 4 HOURS 4 6 Schedule 1 Factory Default 3 minute prime 3450 RPM...

Страница 11: ...URS 6 8 HOURS 8 10 HOURS 10 12 HOURS 12 18 HOURS 18 24 1750 RPM 1150 RPM 0 RPM 1850 RPM 1250 RPM 0 RPM RPM 1150 RPM 0 RPM RPM 3250 RPM 0 RPM RPM FOR USE WITH CONNECTED POOL PUMPTIMER FOR USE WITH CONN...

Страница 12: ...T SCHEDULES SCHEDULE PRIME WHEN MOTOR STARTS FROM A STOPPED POSITION HOURS 0 2 HOURS 2 4 HOURS 4 6 H Schedule 1 Factory Default 3 minute prime 3450 RPM 3450 RPM 2850 RPM Schedule 2 3 minute prime 3450...

Страница 13: ...URS 6 8 HOURS 8 10 HOURS 10 12 HOURS 12 18 HOURS 18 24 2250 RPM 1550 RPM 0 RPM 2150 RPM 1450 RPM 0 RPM 1950 RPM 1350 RPM 0 RPM 0 RPM 1850 RPM 1250 RPM 0 RPM 0 RPM 1750 RPM 1150 RPM 0 RPM 0 RPM 1650 RP...

Страница 14: ...ec NOT RUNNING RUNNING any speed RUNNING high speed PRESS HOLD for 3 Seconds 3 sec PRESS CURRENT SCHEDULE NOTE To confirm the newly set schedule the motor will automatically go into Schedule Check Mod...

Страница 15: ...een Evo motor will run for an additional 1 hour If the temperature is above the threshold the VGreen Evo motor will automatically return to the 24 hour based schedule 7 0 CARE AND MAINTENANCE The VGre...

Страница 16: ...nstalled with a mechanical time clock the off on trippers will restart the schedule daily when the on tripper applies power If you wish to operate at another schedule or reset the current schedule ref...

Страница 17: ...will automatically restart after 6 minutes VGREEN EVO MOTOR IS NOISY Debris in contact with fan Check that back of VGreen Evo motor is free from dirt and debris Use compressed air to clean Debris in s...

Страница 18: ...18 INSTALLATION NOTES PAGE...

Страница 19: ......

Страница 20: ...2021 Regal Beloit Corporation All Rights Reserved MCIM21013E Form C0065E R20 Regal Beloit America Inc 531 North Fourth Street Tipp City OH 45371 Customer Service 866 887 5216 Email pooldist regalbeloi...