The flue should not have horizontal runs of more than 300 mm (12”).
Single walled flue pipe gives a better use of the available heat. Where there
exists a danger of touching the hot flue pipe, it can be screened off with a flue
guard. The flue pipe can reach a temperature of 250 degrees centigrade on maximum
out put. Use Refleks flue pipe and use always the same diameter flue pipe as the
flue outlet on the stove.
6. DECK FLANGE (see drawing page 5)
The deck flange has an insulated ring which has a diameter 50 mm (2”) greater
than the flue diameter. When fitting this insulation ring is on the bottom of the
flange and goes through the deck. A water tight mastic should be used between
deck and flange on fitting.
7. FLUE (CHIMNEY) ABOVE DECK LEVEL
To create the best up draught through the stove, an insulated flue pipe is
recommended above deck level, together with a special Refleks cowl on top.
8. OILTANK AND FUEL SUPPLY PIPE
The fuel oil tank should be installed max. 2000 mm (78”) and min. 200 mm (8”)
above the oil stoves regulator.
The tank is supplied with a brass compression ring and nut, so the 8 mm diameter
copper fuel pipe can be easily fitted.
A heat sensitive safety fuel valve is fitted on the oil control. This functions
as a stop cock, and at the same time shuts down the fuel supply in the event of
fire or overheating, when the air temperature at the valve exceeds 70 degrees
centigrade the fuel supply is shut off.
A heat sensitive safety fuel valve and a fuel oil filter improves the systems
reliability.
With a high flue the round cowl is used but with
a low flue, the model “H” cowl is used to
prevent down draft in the flue.
The best type of flue should be free of obstruc-
tion that can create turbulence round the cowl,
as shown in drawing (2).If this cannot be achie-
ved, there should be at least 400 mm (16”) from
the bottom of the cowl to the wheelhouse roof.
A:If down draught occurs it may help to install
the smoke pipe as shown in sketch. Be sure to
mount the cap above the pilot house height.
B:If the stove is installed as shown in sketch -
we recommend placing the regulator under the
draught pipe i.e. towards the stem.