English
Instruction Manual HY-TELL
4
3.
Application
1.
Cut the pipe to the correct length for bending.
2.
Select the right size of the former and assemble it on the HY-TELL
3.
Select the counterformers in the right size and assemble it on the HY-TELL. Turn
the written parts with the appropriate size towards the former.
4.
The Angle Master can be positioned on the HY-TELL. The position is defined by
two pinch, magnets are intended for the necessary hold.
5.
Place the matching tube in the formers.
6.
Turn the rotary knob on the left to the stop clockwise.
7.
Pump until the correct bending angle is reached. If the Angle Master on position,
the angle can be read comfortably.
8.
Turn the rotary knob in counter-directing direction to relax the tool and remove
the curved tube.
9.
Use the saved power for the next step.
3.1.
Tube Bender Diameter
In the following table is a list of the diameter that supports the HY-TELL and the
matching metric equivalent.
inch
corresponds to
mm
Can be used
for…
1/4’’
6.35mm
6mm
5/16’’
7.937mm
8mm
3/8’’
9.525mm
10mm
1/2'’
12.7mm
12mm
5/8’’
15.875mm
16mm
3/4’’
19.050mm
18mm
7/8’’
22.225mm
22mm