background image

UPC-590L-M Up-Converter Installation and Operation 

See last page for copyright and document information, File: Reeve_UPC590_Instructions.docx, Page 1 

1. Description 

 

The model UPC-590L-M consists of two identical heterodyne converters with 5 to 85 MHz RF input and 205 to 

285 MHz IF output. It is designed for use with the Long Wavelength Array (LWA) Antenna and includes 15 dB of 

attenuation in each IF output path. The UPC-590L-M has the same dimensions and form factor as the LWA 

Power Coupler and Callisto instruments. Because the LWA Antenna has built-in front-end electronics with low 

noise figure and high gain, the UPC-590L-M has no RF input preamplification.  

 

The UPC-590L-M panel layouts are shown below. The front panel (left) has connectors for power (2.1 x 5.5 mm 

coaxial jack, center positive), a power switch and power indicator and two output connectors for the IF to the 

receivers (type N-female). The rear panel (right) has two input connectors for the RF from the LWA Power 

Coupler (type N-female). 

 

 

 

The basic configuration is shown below. The Converter is inserted between the LWA Power Coupler and the 

Callistos instrument or other receivers. 

 

 

 

 

Содержание UPC-590L-M

Страница 1: ...the LWA Power Coupler and Callisto instruments Because the LWA Antenna has built in front end electronics with low noise figure and high gain the UPC 590L M has no RF input preamplification The UPC 59...

Страница 2: ...h quality It is recommended that ferrite beads be placed on the power supply lead at both the Converter end and power supply end Clamshell beads will allow several windings of the power leads to be wr...

Страница 3: ...listo exe 4 Open the Frequency Genie software tool and load the spectral overview from step 3 5 For the UPC 590 up converter setup Frequency Genie as follows Channel selection method Minimum detection...

Страница 4: ...not critical but must be different for each polarization 10 Edit scheduler cfg for the desired observing schedule 11 Open callisto exe It will automatically load the new frequency file 12 If callisto...

Страница 5: ...eated five times to allow the tuner synthesizer to stabilize when starting a new sweep The amount of repetition is set by the nonlinchans parameter in params cfg file of the Frequency Genie Spectrum p...

Страница 6: ...pe N female Input voltage 12 Vdc Input current 120 mA maximum Input power connector 2 1x5 5 mm coaxial jack center positive Gain 22 dB with internal 20 dB attenuator in each channel Dimensions 168 mm...

Страница 7: ...lying or removing power from either unit Maintenance The Converter requires very little periodic maintenance Converter maintenance described below should be performed when performing regular maintenan...