12
8540571 - 28/04/2008 - Rev.6
MASTER MODELS - 5 poles M12 Secondary connector.
PIN
COLOR
NAME
TYPE
DESCRIPTION
FUNCTIONING
1
Brown
24VDC - +24 VDC power supply
-
3
Blue
0VDC - 0 VDC power supply
-
5
Grey
PE - Ground connection
-
2
White
SLAVE1 INPUT
4
Black
SLAVE2 INPUT
Slave OSSD outputs
readout
According the normative
EN61131-2
(PNP active high)
Table 4
MASTER MODELS - 8 poles M12 Primary connector.
STANDARD MODELS - 8 poles M12 connector.
PIN
COLOR
NAME
TYPE
DESCRIPTION
FUNCTIONING
2
Brown
24VDC - +24 VDC power supply
-
7
Blue
0VDC - 0 VDC power supply
-
8
Red
PE - Ground connection
-
1
White
OSSD1 OUTPUT
3
Green
OSSD2 OUTPUT
Safety static outputs
PNP active high
5
Grey
SEL_A INPUT
6
Pink
SEL_B INPUT
Barrier configuration
4
Yellow
K1_K2 INPUT
External contactors
Feedback
According the normative EN61131-2
(ref. Par. "Configuration and operation
modes")
Table 5
WARNINGS REGARDING THE CONNECTION CABLES
•
For connections over 50 m long, use cables with a cross-section area
of 1 mm
2
.
•
The power supply to the barrier should be kept separate from that to other
electric power equipment (electric motors, inverters, frequency converters) or
other sources of disturbance.
•
Connect the Emitter and the Receiver to the ground outlet.
•
The connection cables must follow a different route to that of the other power
cables.