Reer SAFEGATE M SG BOX RST Скачать руководство пользователя страница 6

 

M SG BOX RST 

www.reersafety.com

  

 

 

8541290 01 • 24/03/2020 • Rev.0 

 

13 

SIGNALS 

SIGNAL 

CONDITION 

MEANING 

OUTPUT STATUS 

(White) 

ON 

Outputs active 

OFF 

(Low intensity blinking)

 

Light curtain occupied: outputs disabled 

SAFETY RELAYS TECHNICAL DATA  

The M SG BOX RST module uses two safety relays with guided contacts for the output circuit.  

These relays are specified by the manufacturer for voltages and currents greater than those indicated 
in  the  technical  data;  nevertheless  to  guarantee  correct  insulation  and  avoid  damage  or  premature 
aging,  protect  each  output  line  with  a 

3.15  A  delayed  fuse

  and  verify  that  the  features  of  the  load 

conform to the indications on the following table. 

 

TECHNICAL DATA

 

Number of contacts 

2N.A. - 1N.C.* 

Relay category (according to 
EN60947-5-1) 

AC15 / DC13 

Max commutable voltage 

250Vac, 24Vdc 

Min commutable voltage 

10Vac/10Vdc 

Max commutable current 

2A 

Min commutable current 

10mA@24Vdc 

Number of commutations (life) 

> 50 x 10

3  

(el) / > 40 x 10

(mech) 

 

* 1N.C. = DO NOT USE  AS A SAFETY CONTACT 

MECHANICAL DIMENSIONS 

 

All dimensions are expressed in mm 

Содержание SAFEGATE M SG BOX RST

Страница 1: ...itches for the configuration of the barrier itself DESCRIPTION M SG BOX RST is characterized by Luminous push button for restart and output status indication Connectors for wiring the box to the barri...

Страница 2: ...9 CONFIGURATION The configuration of the operating modes is described below This configuration is performed following the descriptions of the tables below by setting the various jumper connectors and...

Страница 3: ...matic Mode without EDM DIP SWITCH SW1 1 2 3 4 5 6 7 8 on off DIP SWITCH SW2 1 2 3 4 5 6 7 8 on off Automatic Mode with EDM internal relays DIP SWITCH SW1 1 2 3 4 5 6 7 8 on off DIP SWITCH SW2 1 2 3 4...

Страница 4: ...al relays DIP SWITCH SW1 1 2 3 4 5 6 7 8 on off DIP SWITCH SW2 1 2 3 4 5 6 7 8 on off Manual Mode without EDM external relays DIP SWITCH SW1 1 2 3 4 5 6 7 8 on off DIP SWITCH SW2 1 2 3 4 5 6 7 8 on of...

Страница 5: ...1 CJ2 and CJ3 Terminal tightening torque 4 4lb in 0 5 Nm is mandatory Use 60 75 C copper Cu conductor only Wire size range AWG 12 30 solid stranded UL Terminal board CJ1 CLAMP NAME DESCRIPTION 1 NA2_B...

Страница 6: ...ed in the technical data nevertheless to guarantee correct insulation and avoid damage or premature aging protect each output line with a 3 15 A delayed fuse and verify that the features of the load c...

Страница 7: ...sal helps to avoid any negative impact on the environment and health and encourages re use and recycling of the materials the equipment is made of In each individual Member State of the European Union...

Страница 8: ...www reersafety com M SG BOX RST 16 8541290 01 24 03 2020 Rev 0 All REER Safegate manuals and configuration software are available at www reersafety com download safegate...

Отзывы: