INTERCONNECTION MODULES 

 

SAFEGATE M SG BOX RST 

GENERAL 

The SAFEGATE M SG BOX RST modules are accessory devices designed to make the wiring of the 
SAFEGATE S / SAFEGATE TRX-S,  barriers  fast  and  safe,  as  well  as  provide  the  main  controls 
necessary for their operation close to the protected gate. 

In addition to the safety relays with guided contacts piloted and monitored by the light curtain, terminal 
blocks for connecting the cables, jumpers and dip-switches for the configuration of the barrier itself. 

DESCRIPTION 

M SG BOX RST is characterized by: 

  Luminous push-button for restart and output status indication. 

  Connectors for wiring the box to the barrier: 

 

12 M12-8 poles male for TRX-S Active Element (or SAFEGATE S Receiver); 

 

12 M12-5 poles female for SAFEGATE S Emitter. 

  Fairlead for the connections toward the machine of: 

 

power supply; 

 

connection with the output contacts of the internal safety relays and relative EDM; 

 

output signals which indicate the status of the safety light curtain. 

 
 
 

 

 

Figure 4 - M SG BOX RST 

– Connections and signals 

 

 

KEY SELECTOR FOR 

OVERRIDE 

CABLE 

FAIRLEAD 

CONNECTOR 

EMITTER 

(SAFEGATE S) 

CONNECTOR 

ACTIVE ELEMENT 

(SAFEGATE TRX-S) 

RECEIVER 

(SAFEGATE S) 

Содержание SAFEGATE M SG BOX RST

Страница 1: ...itches for the configuration of the barrier itself DESCRIPTION M SG BOX RST is characterized by Luminous push button for restart and output status indication Connectors for wiring the box to the barri...

Страница 2: ...9 CONFIGURATION The configuration of the operating modes is described below This configuration is performed following the descriptions of the tables below by setting the various jumper connectors and...

Страница 3: ...matic Mode without EDM DIP SWITCH SW1 1 2 3 4 5 6 7 8 on off DIP SWITCH SW2 1 2 3 4 5 6 7 8 on off Automatic Mode with EDM internal relays DIP SWITCH SW1 1 2 3 4 5 6 7 8 on off DIP SWITCH SW2 1 2 3 4...

Страница 4: ...al relays DIP SWITCH SW1 1 2 3 4 5 6 7 8 on off DIP SWITCH SW2 1 2 3 4 5 6 7 8 on off Manual Mode without EDM external relays DIP SWITCH SW1 1 2 3 4 5 6 7 8 on off DIP SWITCH SW2 1 2 3 4 5 6 7 8 on of...

Страница 5: ...1 CJ2 and CJ3 Terminal tightening torque 4 4lb in 0 5 Nm is mandatory Use 60 75 C copper Cu conductor only Wire size range AWG 12 30 solid stranded UL Terminal board CJ1 CLAMP NAME DESCRIPTION 1 NA2_B...

Страница 6: ...ed in the technical data nevertheless to guarantee correct insulation and avoid damage or premature aging protect each output line with a 3 15 A delayed fuse and verify that the features of the load c...

Страница 7: ...sal helps to avoid any negative impact on the environment and health and encourages re use and recycling of the materials the equipment is made of In each individual Member State of the European Union...

Страница 8: ...www reersafety com M SG BOX RST 16 8541290 01 24 03 2020 Rev 0 All REER Safegate manuals and configuration software are available at www reersafety com download safegate...